{"id":17980,"date":"2026-10-19T19:16:23","date_gmt":"2026-10-19T19:16:23","guid":{"rendered":"https:\/\/shop.germansts.de\/?post_type=product&#038;p=17980"},"modified":"2026-10-19T19:16:40","modified_gmt":"2026-10-19T19:16:40","slug":"lapp-nyy-j-3x25-re-06-1kv-15500103","status":"publish","type":"product","link":"https:\/\/shop.germansts.de\/en\/product\/lapp-nyy-j-3x25-re-06-1kv-15500103\/","title":{"rendered":"LAPP NYY-J 3\u00d72,5 RE 0,6\/1kV \u2013 15500103"},"content":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<h2>NYY-J 3&#215;2,5 RE 0,6\/1kV<\/h2>\n<p>Starkstromkabel; 3&#215;2.5 RE; NYY-J; U<sub>0<\/sub>\/U: 0,6\/1 kV; blankes Kupfer; PVC; VDE zertifiziert; feste Verlegung<\/p>\n<p>Zuschnittl\u00e4ngen: 10, 20, 50 und 100 m. Andere L\u00e4ngen auf Anfrage.<\/p>\n<h3>Vorteile<\/h3>\n<ul>\n<li>Direkte Erdverlegbarkeit dank widerstandsf\u00e4higem Mantelwerkstoff (PVC). Das robuste Mantelmaterial sch\u00fctzt vor sch\u00e4dlichen Umwelteinfl\u00fcssen sowie Chemikalien.<\/li>\n<li>Klassifiziertes Brandverhalten gem\u00e4\u00df EU-Richtlinie 305\/2011 (BauPVO\/CPR) mit Artikelnummer-Auswahl auf der LAPP-Website.<\/li>\n<li>Kupferleiter weisen h\u00f6here Strombelastbarkeit und niedrigeren Spannungsabfall auf, verglichen mit Aluminiumleitern und gemessen am Leiterquerschnitt.<\/li>\n<\/ul>\n<h3>Anwendungsbereiche<\/h3>\n<ul>\n<li>Universell einsetzbar zum Energieversorgungsanschluss von Geb\u00e4uden und Industrieanlagen.<\/li>\n<li>F\u00fcr die Energieverteilung in Kraft- und Umspannwerken geeignet.<\/li>\n<li>F\u00fcr mittlere mechanische Beanspruchung geeignet.<\/li>\n<li>F\u00fcr den Au\u00dfenbereich geeignet, unter Beachtung des Temperaturbereichs.<\/li>\n<\/ul>\n<h3>Produkthinweise<\/h3>\n<ul>\n<li>Abk\u00fcrzungen \u201eRE\u201c, \u201eRM\u201c, \u201eSE\u201c, \u201eSM\u201c:<br \/>\nR = runde Leiterform;<br \/>\nS = sektorf\u00f6rmiger Leiter;<br \/>\nE = eindr\u00e4htiger Leiter;<br \/>\nM = mehrdr\u00e4htiger Leiter<\/li>\n<li>Handels-Produkt, kein LAPP-Produkt.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<details>\n<summary>Allgemeine Informationen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Produkttyp<\/th>\n<td>Starkstromkabel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Gewicht<\/th>\n<td>212 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Kupferzahl<\/th>\n<td>72 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Industrie Segment<\/th>\n<td>Landmaschinen; Automotive; Baumaschinen; Stromnetze; Lebensmittelindustrie; Medizintechnik &amp; Pharma; Verpackungsindustrie; Prozessindustrie; Erneuerbare Energien: Solar; Geb\u00e4udeautomation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Zolltarifnummer<\/th>\n<td>85444991<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Elektrische Kennwerte<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nennspannung<\/th>\n<td>U0\/U: 0,6\/1 kV AC rms nach IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pr\u00fcfspannung<\/th>\n<td>4 kV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Strombelastbarkeit nach<\/th>\n<td>VDE 0276-603<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. Leiterwiderstand bei 20 \u00b0C<\/th>\n<td>7,41 \u03a9\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produktaufbau<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">N-Deutsche Normkabel<\/th>\n<td>NYY-J<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiter Anzahl\/Gr\u00f6\u00dfe<\/th>\n<td>3G2,5 RE<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiternennquerschnitt (metrisch)<\/th>\n<td>2,5 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitermaterial<\/th>\n<td>blankes Kupfer<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiteraufbau<\/th>\n<td>IEC 60228 Klasse 1: eindr\u00e4htig<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiterform<\/th>\n<td>rund<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiter Abk\u00fcrzung<\/th>\n<td>3&#215;2.5 RE<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Einschlie\u00dflich Schutzleiter<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Anzahl Adern<\/th>\n<td>3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">F\u00fcllmischung \u00fcber dem Aderverband<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Geschirmt<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitungsform<\/th>\n<td>rund<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial der Aderisolation<\/th>\n<td>Polyvinylchlorid<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial der Aderisolation, Kurzform<\/th>\n<td>PVC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Au\u00dfenmantels<\/th>\n<td>Polyvinylchlorid<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Au\u00dfenmantels, Kurzform<\/th>\n<td>PVC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Au\u00dfenmantelfarbe<\/th>\n<td>schwarz<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Aderidentifizierung<\/th>\n<td>Farben<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produkteigenschaften<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Einsatzgebiet<\/th>\n<td>feste Verlegung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Erdverlegbar<\/th>\n<td>direkt; im Kabelgraben; im Schutzrohr<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">F\u00fcr Torsionsbelastung<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius, festverlegt<\/th>\n<td>12 x Au\u00dfendurchmesser<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt<\/th>\n<td>-40 \u00b0C bis 70 \u00b0C max. Leitertemperatur<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt max<\/th>\n<td>70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Montagetemperatur min.<\/th>\n<td>-5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Montagetemperatur max.<\/th>\n<td>50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrigkeit nach<\/th>\n<td>IEC 60332-1-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig nach<\/th>\n<td>EN 50525-1 (Leitungen mit schwarzem Mantel sind f\u00fcr dauerhaften Einsatz im Freien geeignet)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogenfrei<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u00d6lbest\u00e4ndig<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">LABS-frei<\/th>\n<td>Ja<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Zertifizierungen und Normen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE gekennzeichnet<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">EAC zertifiziert<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">EAC Zertifizierungsnummer<\/th>\n<td>\u0415\u0410\u042d\u0421 RU \u0421-DE.\u0410\u042e64.\u0412.00091\/19,  \u0415\u0410\u042d\u0421 RU \u0421-DE.\u0410\u042e64.\u0412.00110\/20<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">VDE zertifiziert<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Produktnorm VDE<\/th>\n<td>VDE 0276-603<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">HAR-zertifiziert<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR Brandklasse<\/th>\n<td>Eca<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrigkeit nach UN\/ECE-R118 getestet<\/th>\n<td>Nein<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<h3>Datenbl\u00e4tter und Zertifikate<\/h3>\n<ul>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/qNrsq4eQ57oo-kAUb-w-wg~~\/DB1550030DE.pdf\" target=\"_blank\" rel=\"noopener\">Datenblatt: DB1550030DE.pdf<\/a><\/li>\n<\/ul>\n<details>\n<summary>Herstellerhinweise<\/summary>\n<ul>\n<li>Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie  &#8211; soweit verf\u00fcgbar und zur Ver\u00f6ffentlichung freigegeben- auf Anfrage.<\/li>\n<li>Die Fotografien und Grafiken sind nicht ma\u00dfst\u00e4blich und keine detailgetreuen Abbildungen der jeweiligen Produkte.<\/li>\n<li>Die Abwesenheit von LABS-Rohstoffen sch\u00fctzt nicht vor dem potenziellen Risiko einer Kontamination mit lackbenetzungsst\u00f6renden Substanzen bei der sp\u00e4teren Handhabung des Produkts\/der Produkte w\u00e4hrend des Transports, der Lagerung oder der Weiterverarbeitung nach der Lieferung.<\/li>\n<li>Sofern anwendbar, handelt es sich um den Vollmetallpreis ohne Zuschl\u00e4ge und MwSt. Verkauf nur an Firmenkunden.<\/li>\n<li>Handels-Produkt, kein LAPP-Produkt.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Lieferl\u00e4ngen &amp; Bestellbedingungen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Mindestbestellmenge<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Bestellintervall<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Individueller Zuschnitt beim Hersteller<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hersteller-Standardl\u00e4ngen<\/th>\n<td>50 \/ 100 \/ 500 \/ 3000 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/de\/de\/nyy\/p\/15500103\" target=\"_blank\" rel=\"noopener\">Offizielle LAPP Produktinformationen, Datenblatt und Zertifikate<\/a><\/p>\n<p>Hersteller-Nennwerte. Produktabbildung repr\u00e4sentativ; Bauform, Farbe und Abmessungen k\u00f6nnen je Artikel abweichen. Gewichte gelten f\u00fcr das Kabel ohne Verpackung und Trommel. Versand nach verpacktem Gewicht und Ma\u00dfen.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<h2>NYY-J 3&#215;2,5 RE 0,6\/1kV<\/h2>\n<p>Power cables; 3&#215;2.5 RE; NYY-J; U<sub>0<\/sub>\/U: 0,6\/1 kV; Bare copper; PVC; VDE certified; Fixed installation<\/p>\n<p>Cut lengths: 10, 20, 50 and 100 m. Other lengths on request.<\/p>\n<h3>Benefits<\/h3>\n<ul>\n<li>Suitable for direct underground installation thanks to tough sheath material (PVC). The robust jacket material protects against harmful environmental influences and chemicals.<\/li>\n<li>Classified fire behaviour according to EU Directive 305\/2011 (BauPVO\/CPR) with article number selection on the LAPP website.<\/li>\n<li>Copper conductors have a higher current rating and a lower voltage drop compared to aluminium conductors and measured at the conductor cross-section.<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n<li>Can be used universally for connecting the power supply in buildings and industrial facilities.<\/li>\n<li>Suitable for energy distribution in power and converter stations.<\/li>\n<li>Suitable for medium mechanical stress.<\/li>\n<li>Suitable for outdoor use, subject to the temperature range.<\/li>\n<\/ul>\n<h3>Product notes<\/h3>\n<ul>\n<li>Abbreviations &#8222;RE\u201c, &#8222;RM\u201c, &#8222;SE\u201c, &#8222;SM\u201c:<br \/>\nR = round conductor form;<br \/>\nS = sector-shaped conductor;<br \/>\nE = single-wire conductor;<br \/>\nM = multi-wire conductor<\/li>\n<li>Trade product, not a LAPP product.<\/li>\n<\/ul>\n<h2>Technical specifications<\/h2>\n<details>\n<summary>General information<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Product type<\/th>\n<td>Power cables<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Weight<\/th>\n<td>212 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Copper index<\/th>\n<td>72 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Industry segment<\/th>\n<td>Agricultural &amp; Farm Machinery; Automotive; Construction Machinery; Power Grids; Food &amp; Beverage; Healthcare &amp; Pharma; Packaging; Processing Industries; Renewable Energy: Solar; Building Automation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">customs code<\/th>\n<td>85444991<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Electrical parameters<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nominal voltage<\/th>\n<td>U0\/U: 0,6\/1 kV AC rms according to IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Test voltage<\/th>\n<td>4 kV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Current rating according to<\/th>\n<td>VDE 0276-603<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. conductor resistance at 20\u00b0C<\/th>\n<td>7.41 \u03a9\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product design<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">N-German standard cables<\/th>\n<td>NYY-J<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor number\/size<\/th>\n<td>3G2,5 RE<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal conductor cross-section (metric)<\/th>\n<td>2.5 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor material<\/th>\n<td>Bare copper<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor design<\/th>\n<td>IEC 60228 class 1: solid conductor<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor shape<\/th>\n<td>Round<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor abbreviation<\/th>\n<td>3&#215;2.5 RE<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Including protective earth<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Number of cores<\/th>\n<td>3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Filling compound over the core assembly<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Shielded<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cable shape<\/th>\n<td>Round<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core insulation basic material<\/th>\n<td>Polyvinylchloride<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core insulation basic material, short form<\/th>\n<td>PVC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Basic material of outer sheath<\/th>\n<td>Polyvinylchloride<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Basic material of outer sheath, short form<\/th>\n<td>PVC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Outer sheath colour<\/th>\n<td>black<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core identification<\/th>\n<td>Colours<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product features<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Application area<\/th>\n<td>Fixed installation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Suitable for underground installation<\/th>\n<td>direct; in cable trench; in protective cable conduit<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">For torsional load<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius, stationary<\/th>\n<td>12 x outer diameter<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation<\/th>\n<td>-40 \u00b0C to 70 \u00b0C max. conductor temperature<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation max<\/th>\n<td>70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Installation temperature min.<\/th>\n<td>-5 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. assembly temperature<\/th>\n<td>50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame-retardant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame retardance according to<\/th>\n<td>IEC 60332-1-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant according to<\/th>\n<td>EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogen-free<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil-resistant<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">PWIS-free<\/th>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Certifications and standards<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE marking<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">EAC-certified<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">EAC certification number<\/th>\n<td>\u0415\u0410\u042d\u0421 RU \u0421-DE.\u0410\u042e64.\u0412.00091\/19,  \u0415\u0410\u042d\u0421 RU \u0421-DE.\u0410\u042e64.\u0412.00110\/20<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">VDE certified<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Product standard VDE<\/th>\n<td>VDE 0276-603<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">HAR certified<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR fire class<\/th>\n<td>Eca<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame retardance tested according to UN\/ECE-R118<\/th>\n<td>No<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<h3>Datasheets and certificates<\/h3>\n<ul>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/TSN4TGLuNP_AY_1fFbCnlg~~\/DB1550030EN.pdf\" target=\"_blank\" rel=\"noopener\">Data sheet: DB1550030EN.pdf<\/a><\/li>\n<\/ul>\n<details>\n<summary>Manufacturer notes<\/summary>\n<ul>\n<li>Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.<\/li>\n<li>Photographs and graphics are not to scale and do not represent detailed images of the respective products.<\/li>\n<li>The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.<\/li>\n<li>If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.<\/li>\n<li>Trade product, not a LAPP product.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Supply lengths &amp; ordering conditions<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Minimum order quantity<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Order quantity interval<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer individual cut lengths<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer standard lengths<\/th>\n<td>50 \/ 100 \/ 500 \/ 3000 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/en\/de\/nyy\/p\/15500103\" target=\"_blank\" rel=\"noopener\">Official LAPP product information, datasheet and certificates<\/a><\/p>\n<p>Manufacturer nominal values. Representative product image; construction, colour and dimensions may vary by article. Cable weights exclude packaging and reels. Shipping depends on packed weight and dimensions.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<p>Starkstromkabel; 3&#215;2.5 RE; NYY-J; U<sub>0<\/sub>\/U: 0,6\/1 kV; blankes Kupfer; PVC; VDE zertifiziert; feste Verlegung<\/p>\n<p>Zuschnitt: 10 \/ 20 \/ 50 \/ 100 m. Andere L\u00e4ngen auf Anfrage.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<p>Power cables; 3&#215;2.5 RE; NYY-J; U<sub>0<\/sub>\/U: 0,6\/1 kV; Bare copper; PVC; VDE certified; Fixed installation<\/p>\n<p>Cut lengths: 10 \/ 20 \/ 50 \/ 100 m. Other lengths on request.<\/p>\n<\/div>","protected":false},"featured_media":17556,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[140],"product_cat":[31],"product_tag":[],"class_list":["post-17980","product","type-product","status-publish","has-post-thumbnail","product_brand-lapp","product_cat-niederspannungs-energiekabel","desktop-align-left","tablet-align-left","mobile-align-left","first","outofstock","sale","taxable","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product\/17980","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/comments?post=17980"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media\/17556"}],"wp:attachment":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media?parent=17980"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_brand?post=17980"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_cat?post=17980"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_tag?post=17980"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}