{"id":23939,"date":"2026-10-19T20:11:32","date_gmt":"2026-10-19T20:11:32","guid":{"rendered":"https:\/\/shop.germansts.de\/?post_type=product&#038;p=23939"},"modified":"2026-10-19T20:11:42","modified_gmt":"2026-10-19T20:11:42","slug":"lapp-oelflex-classic-110-ch-5g4-10035095","status":"publish","type":"product","link":"https:\/\/shop.germansts.de\/en\/product\/lapp-oelflex-classic-110-ch-5g4-10035095\/","title":{"rendered":"LAPP \u00d6LFLEX\u00ae CLASSIC 110 CH 5G4 \u2013 10035095"},"content":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<h2>\u00d6LFLEX\u00ae CLASSIC 110 CH 5G4<\/h2>\n<p>Anschluss- und Steuerleitung; 5G4; U<sub>0<\/sub>\/U: 300\/500 V; HFFR; Aderidentifizierung: Nummern; Geschirmt; UL recognized; flexibel<\/p>\n<p>Zuschnittl\u00e4ngen: 10, 20, 50 und 100 m. Andere L\u00e4ngen auf Anfrage.<\/p>\n<h3>Vorteile<\/h3>\n<ul>\n<li>Einfache Handhabung und Installation aufgrund sehr flexibler Ausf\u00fchrung.<\/li>\n<li>Halogenfreie und hoch flammwidrige Materialien reduzieren die Gefahr von Brandfortleitung, hoher Rauchdichte und toxischen Rauchgasen im Brandfall.<\/li>\n<li>Idealer Schutz vor elektromagnetischer St\u00f6rung durch Kupferabschirmgeflecht mit hohem Bedeckungsgrad.<\/li>\n<li>Klassifiziertes Brandverhalten gem\u00e4\u00df EU-Richtlinie 305\/2011 (BauPVO\/CPR) mit Artikelnummer-Auswahl auf der LAPP-Website.<\/li>\n<li>Hohe elektrische Sicherheit durch 4000 V-Pr\u00fcfspannung.<\/li>\n<li>Erh\u00f6ht \u00f6lbest\u00e4ndig nach DIN EN 50363-4-1 (TM5) sowie UL OIL RES I und OIL RES II.<\/li>\n<li>UL-Zertifizierung gem\u00e4\u00df Technischen Daten erm\u00f6glicht Verwendung des Produkts im nordamerikanischen Raum.<\/li>\n<li>Produkt mit Mehrfach-Zertifizierung erm\u00f6glicht universellen Einsatz, reduziert Teilevielfalt und sorgt so f\u00fcr Einsparungen in der Logistik.<\/li>\n<\/ul>\n<h3>Anwendungsbereiche<\/h3>\n<ul>\n<li>F\u00fcr die Geb\u00e4udeverkabelung zur Einhaltung besonderer Brandschutzanforderungen.<\/li>\n<li>Universell einsetzbar zur Verdrahtung von maschineninternen und anlagen\u00fcbergreifenden Steuerkreisen.<\/li>\n<li>Speziell f\u00fcr Umgebungen, in denen elektromagnetische Vertr\u00e4glichkeit (EMV) gefordert ist.<\/li>\n<li>Zur festen Verlegung und gelegentlichen Bewegung ohne Zugbeanspruchung.<\/li>\n<li>Einsetzbar in trockenen und feuchten Umgebungen.<\/li>\n<li>F\u00fcr mittlere mechanische Beanspruchung geeignet.<\/li>\n<li>HFFR-Au\u00dfenmantel ist weitgehend best\u00e4ndig gegen\u00fcber S\u00e4uren und Laugen.<\/li>\n<li>F\u00fcr den Au\u00dfenbereich geeignet.<\/li>\n<li>Flexibler Einsatz bei bis zu \u201130 \u00b0C m\u00f6glich.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<details>\n<summary>Allgemeine Informationen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Marke<\/th>\n<td>\u00d6LFLEX\u00ae<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Produkttyp<\/th>\n<td>Anschluss- und Steuerleitung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Gewicht<\/th>\n<td>407 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Kupferzahl<\/th>\n<td>251.5 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Industrie Segment<\/th>\n<td>Landmaschinen; Montageautomation; Automotive; Baumaschinen; Stromnetze; Lebensmittelindustrie; Medizintechnik &amp; Pharma; L\u00fcftungs- &amp; Klimatechnik; Intralogistik; Aufz\u00fcge; Werkzeugmaschinen; Verpackungsindustrie; Prozessindustrie; Robotik; Schiffbau; Geb\u00e4udeautomation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Zolltarifnummer<\/th>\n<td>85444995<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Elektrische Kennwerte<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nennspannung<\/th>\n<td>U0\/U: 300\/500 V AC rms nach IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Bemessungsspannung<\/th>\n<td>600 V AC rms nach UL AWM<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pr\u00fcfspannung Ader\/Ader<\/th>\n<td>4 kV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pr\u00fcfspannung Ader\/Schirm<\/th>\n<td>4 kV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. Leiterwiderstand bei 20 \u00b0C<\/th>\n<td>4,95 \u03a9\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Betriebskapazit\u00e4t Ader\/Ader (800Hz), ca.<\/th>\n<td>100 nF\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Betriebskapazit\u00e4t Ader\/Schirm (800Hz), ca<\/th>\n<td>155 nF\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Induktivit\u00e4t (800Hz), ca.<\/th>\n<td>0,605 mH\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produktaufbau<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Leitungsabmessung<\/th>\n<td>5G4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiternennquerschnitt (metrisch)<\/th>\n<td>4 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiternennquerschnitt (AWG)<\/th>\n<td>12 AWG<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">F\u00fchrender Leiterquerschnitt<\/th>\n<td>mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitermaterial<\/th>\n<td>blankes Kupfer<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiteraufbau<\/th>\n<td>IEC 60228 Klasse 5: feindr\u00e4htig<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Einschlie\u00dflich Schutzleiter<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Anzahl Adern<\/th>\n<td>5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Verseilart<\/th>\n<td>Lagenverseilung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Geschirmt<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Art des Gesamtschirm<\/th>\n<td>verzinntes Kupfergeflecht<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nennaussendurchmesser<\/th>\n<td>14,9 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitungsform<\/th>\n<td>rund<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial der Aderisolation<\/th>\n<td>Halogenfreie Mischung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial der Aderisolation, Kurzform<\/th>\n<td>HFFR<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Innenmantels<\/th>\n<td>Halogenfreie Mischung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Innenmantels  Kurzform<\/th>\n<td>HFFR<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Innenmantel Farbe<\/th>\n<td>grau<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Au\u00dfenmantels<\/th>\n<td>Halogenfreie Mischung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Au\u00dfenmantels, Kurzform<\/th>\n<td>HFFR<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Au\u00dfenmantelfarbe<\/th>\n<td>grau<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Aderidentifizierung<\/th>\n<td>Nummern<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ader Farbcode<\/th>\n<td>VDE 0293-1; EN 50334<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produkteigenschaften<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Einsatzgebiet<\/th>\n<td>flexibel; feste Verlegung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">F\u00fcr Torsionsbelastung<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius, festverlegt<\/th>\n<td>6 x Au\u00dfendurchmesser<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius in mm, festverlegt<\/th>\n<td>89,4 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius, gelegentlich bewegt<\/th>\n<td>15 x Au\u00dfendurchmesser<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius in mm, gelegentlich bewegt<\/th>\n<td>223,5 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt<\/th>\n<td>bis 75 \u00b0C max. Leitertemperatur nach UL AWM; -40 \u00b0C bis 80 \u00b0C max. Leitertemperatur<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt max<\/th>\n<td>80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, gelegentlich bewegt<\/th>\n<td>bis 75 \u00b0C max. Leitertemperatur nach UL AWM; -30 \u00b0C bis 70 \u00b0C max. Leitertemperatur<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, gelegentlich bewegt max<\/th>\n<td>75 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, gelegentlich bewegt min<\/th>\n<td>-30 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrigkeit nach<\/th>\n<td>IEC 60332-1-2; IEC 60332-3-22; IEC 60332-3-24; UL Cable Flame Test<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Geringe Rauchgasdichte nach<\/th>\n<td>IEC 61034-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Geringe Toxizit\u00e4t der Brandgase nach<\/th>\n<td>NES 02-713 (\u2264 3)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Korrosivit\u00e4t der Brandgase nach<\/th>\n<td>IEC 60754-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig nach<\/th>\n<td>DIN EN ISO 4892-2 Methode A; EN 50620; EN 50618<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozonbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozonbest\u00e4ndig nach<\/th>\n<td>EN 50396, Methode B<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogenfrei<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogenfreiheit nach<\/th>\n<td>IEC 60754-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u00d6lbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u00d6lbest\u00e4ndigkeit nach<\/th>\n<td>EN 50363-4-1: TM5; UL OILRES I; UL OILRES II<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">LABS-frei<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">LABS-frei nach<\/th>\n<td>VDMA 24364-B2-L<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Zertifizierungen und Normen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE gekennzeichnet<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">EAC zertifiziert<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">EAC Zertifizierungsnummer<\/th>\n<td>\u0415\u0410\u042d\u0421 N RU \u0414-DE.\u0410\u042e64.\u0412.00130\/20<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UL recognized<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UL AWM Zertifizierung<\/th>\n<td>21089 nach UL 758 (e-file number: E63634)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UL listed<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">cUR recognized<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">cUL listed<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CSA zertifiziert<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">VDE zertifiziert<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DNV zertifiziert<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR Brandklasse<\/th>\n<td>B2ca<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR Rauchgasdichte<\/th>\n<td>s1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR Tropfverhalten<\/th>\n<td>d1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR Azidit\u00e4t<\/th>\n<td>a1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrigkeit nach UN\/ECE-R118 getestet<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Brandschutz-gepr\u00fcft f\u00fcr Schienenfahrzeuge<\/th>\n<td>Nein<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<h3>Datenbl\u00e4tter und Zertifikate<\/h3>\n<ul>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/7auOkvSHS_jU30wKsrBXaw~~\/DB10035030DE.pdf\" target=\"_blank\" rel=\"noopener\">Datenblatt: DB10035030DE.pdf<\/a><\/li>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/KmJns9KQShoEWsI0IVdq5A~~\/ZUE63634.pdf\" target=\"_blank\" rel=\"noopener\">Zulassung UL: ZUE63634.pdf<\/a><\/li>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/CxCWIekVH18aSuA2B3_ugg~~\/CE10035030EN.pdf\" target=\"_blank\" rel=\"noopener\">CE Konformit\u00e4tserkl\u00e4rung: CE10035030EN.pdf<\/a><\/li>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/DKfatcRsg5C-yomVDIjW0g~~\/UILCPRDOP17_10035030-1EN.pdf\" target=\"_blank\" rel=\"noopener\">CPR Leistungserkl\u00e4rung: UILCPRDOP17_10035030-1EN.pdf<\/a><\/li>\n<\/ul>\n<details>\n<summary>Herstellerhinweise<\/summary>\n<ul>\n<li>Induktivit\u00e4t und Betriebskapazit\u00e4t sind weder definierte noch kontrollierte elektrische Parameter. Die angegebenen Werte wurden durch Berechnung ermittelt und k\u00f6nnen aufgrund von Toleranzen abweichen.<\/li>\n<li>Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie  &#8211; soweit verf\u00fcgbar und zur Ver\u00f6ffentlichung freigegeben- auf Anfrage.<\/li>\n<li>Die Fotografien und Grafiken sind nicht ma\u00dfst\u00e4blich und keine detailgetreuen Abbildungen der jeweiligen Produkte.<\/li>\n<li>Die Abwesenheit von LABS-Rohstoffen sch\u00fctzt nicht vor dem potenziellen Risiko einer Kontamination mit lackbenetzungsst\u00f6renden Substanzen bei der sp\u00e4teren Handhabung des Produkts\/der Produkte w\u00e4hrend des Transports, der Lagerung oder der Weiterverarbeitung nach der Lieferung.<\/li>\n<li>Sofern anwendbar, handelt es sich um den Vollmetallpreis ohne Zuschl\u00e4ge und MwSt. Verkauf nur an Firmenkunden.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Lieferl\u00e4ngen &amp; Bestellbedingungen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Mindestbestellmenge<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Bestellintervall<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Individueller Zuschnitt beim Hersteller<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hersteller-Standardl\u00e4ngen<\/th>\n<td>50 \/ 500 \/ 1000 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/de\/de\/oelflex-classic-110-ch\/p\/10035095\" target=\"_blank\" rel=\"noopener\">Offizielle LAPP Produktinformationen, Datenblatt und Zertifikate<\/a><\/p>\n<p>Hersteller-Nennwerte. Produktabbildung repr\u00e4sentativ; Bauform, Farbe und Abmessungen k\u00f6nnen je Artikel abweichen. Gewichte gelten f\u00fcr das Kabel ohne Verpackung und Trommel. Versand nach verpacktem Gewicht und Ma\u00dfen.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<h2>\u00d6LFLEX\u00ae CLASSIC 110 CH 5G4<\/h2>\n<p>Power and control cable; 5G4; U<sub>0<\/sub>\/U: 300\/500 V; HFFR; Core identification: Numbers; Shielded; UL recognized; Flexible<\/p>\n<p>Cut lengths: 10, 20, 50 and 100 m. Other lengths on request.<\/p>\n<h3>Benefits<\/h3>\n<ul>\n<li>Easy handling and installation due to very flexible design<\/li>\n<li>Halogen-free and highly flame retardant materials reduce the risk of flame propagation, high smoke density and toxic smoke in the event of a fire.<\/li>\n<li>Ideal protection against electromagnetic interference thanks to copper stranded shielding with a high degree of coverage.<\/li>\n<li>Classified fire behaviour according to EU Directive 305\/2011 (BauPVO\/CPR) with article number selection on the LAPP website.<\/li>\n<li>High electrical safety thanks to 4000 V test voltage.<\/li>\n<li>High oil resistance according to DIN EN 50363-4-1 (TM5), as well as UL OIL RES I and OIL RES II.<\/li>\n<li>UL certification according to technical data enables the product to be used on the North American market.<\/li>\n<li>Product with multiple certifications enables universal use and reduces the variety of parts, thus guaranteeing logistics savings.<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n<li>For structured building cabling for compliance with special fire protection requirements.<\/li>\n<li>For universal use for wiring machine-internal and cross-plant control circuits.<\/li>\n<li>Especially for environments where electromagnetic compatibility (EMC) is required.<\/li>\n<li>For fixed installation and occasional movement without tensile strain.<\/li>\n<li>Can be used in dry and damp environments.<\/li>\n<li>Suitable for medium mechanical stress.<\/li>\n<li>The HFFR outer sheath is highly resistant to acids and alkalis.<\/li>\n<li>Suitable for outdoor use.<\/li>\n<li>Flexible use at temperatures down to -30\u00b0C.<\/li>\n<\/ul>\n<h2>Technical specifications<\/h2>\n<details>\n<summary>General information<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Brand<\/th>\n<td>\u00d6LFLEX\u00ae<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Product type<\/th>\n<td>Power and control cable<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Weight<\/th>\n<td>407 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Copper index<\/th>\n<td>251.5 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Industry segment<\/th>\n<td>Agricultural &amp; Farm Machinery; Assembly Machines; Automotive; Construction Machinery; Power Grids; Food &amp; Beverage; Healthcare &amp; Pharma; HVAC; Intralogistics; Lifts &amp; Elevators; Machine tools; Packaging; Processing Industries; Robotics; Ships &amp; boats; Building Automation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">customs code<\/th>\n<td>85444995<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Electrical parameters<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nominal voltage<\/th>\n<td>U0\/U: 300\/500 V AC rms according to IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Rated voltage<\/th>\n<td>600 V AC rms according to UL AWM<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Test voltage core\/core<\/th>\n<td>4 kV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Test voltage core\/screening<\/th>\n<td>4 kV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. conductor resistance at 20\u00b0C<\/th>\n<td>4.95 \u03a9\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor\/conductor operating capacitance (800Hz), approx.<\/th>\n<td>100 nF\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor\/shielding operating capacitance (800Hz), approx.<\/th>\n<td>155 nF\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Inductance (800 Hz), approx.<\/th>\n<td>0.605 mH\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product design<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Cable dimensions<\/th>\n<td>5G4<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal conductor cross-section (metric)<\/th>\n<td>4 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal conductor cross-section (AWG)<\/th>\n<td>12 AWG<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leading conductor cross-section<\/th>\n<td>mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor material<\/th>\n<td>Bare copper<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor design<\/th>\n<td>IEC 60228 class 5: fine-wire<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Including protective earth<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Number of cores<\/th>\n<td>5<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Stranding type<\/th>\n<td>Layered stranding<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Shielded<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Type of overall screening<\/th>\n<td>Tin-plated copper braiding<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal outer diameter<\/th>\n<td>14.9 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cable shape<\/th>\n<td>Round<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core insulation basic material<\/th>\n<td>Halogen-free compound<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core insulation basic material, short form<\/th>\n<td>HFFR<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Basic material of inner sheath<\/th>\n<td>Halogen-free compound<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">base material inner sheath shortname<\/th>\n<td>HFFR<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Inner sheath colour<\/th>\n<td>grey<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Basic material of outer sheath<\/th>\n<td>Halogen-free compound<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Basic material of outer sheath, short form<\/th>\n<td>HFFR<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Outer sheath colour<\/th>\n<td>grey<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core identification<\/th>\n<td>Numbers<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor colour code<\/th>\n<td>VDE 0293-1; EN 50334<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product features<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Application area<\/th>\n<td>Flexible; Fixed installation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">For torsional load<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius, stationary<\/th>\n<td>6 x outer diameter<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius in mm, fixed installation<\/th>\n<td>89.4 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius, occasionally flexing<\/th>\n<td>15 x outer diameter<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius in mm, occasionally flexing<\/th>\n<td>223.5 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation<\/th>\n<td>to 75 \u00b0C max. conductor temperature according to UL AWM; -40 \u00b0C to 80 \u00b0C max. conductor temperature<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation max<\/th>\n<td>80 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">max. conductor temperature, occasionally moved<\/th>\n<td>to 75 \u00b0C max. conductor temperature according to UL AWM; -30 \u00b0C to 70 \u00b0C max. conductor temperature<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, occasionally moved max<\/th>\n<td>75 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, occasionally moved min<\/th>\n<td>-30 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame-retardant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame retardance according to<\/th>\n<td>IEC 60332-1-2; IEC 60332-3-22; IEC 60332-3-24; UL Cable Flame Test<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Low smoke density according to<\/th>\n<td>IEC 61034-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Low toxicity of combustion gases according to<\/th>\n<td>NES 02-713 (\u2264 3)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Corrosiveness of combustion gases according to<\/th>\n<td>IEC 60754-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant according to<\/th>\n<td>DIN EN ISO 4892-2 method A; EN 50620; EN 50618<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozone-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozone-resistant according to<\/th>\n<td>EN 50396, method B<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogen-free<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogen-free according to<\/th>\n<td>IEC 60754-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil resistance according to<\/th>\n<td>EN 50363-4-1: TM5; UL OILRES I; UL OILRES II<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">PWIS-free<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">PWIS-free according to<\/th>\n<td>VDMA 24364-B2-L<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Certifications and standards<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE marking<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">EAC-certified<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">EAC certification number<\/th>\n<td>\u0415\u0410\u042d\u0421 N RU \u0414-DE.\u0410\u042e64.\u0412.00130\/20<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UL recognized<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UL AWM certification<\/th>\n<td>21089 according to UL 758 (e-file number: E63634)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UL listed<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">cUR recognised<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">cUL listed<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CSA certified<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">VDE certified<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">DNV-certified<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR fire class<\/th>\n<td>B2ca<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR smoke density<\/th>\n<td>s1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR drip behaviour<\/th>\n<td>d1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">CPR acidity<\/th>\n<td>a1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame retardance tested according to UN\/ECE-R118<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Fire protection tested for railway vehicles<\/th>\n<td>No<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<h3>Datasheets and certificates<\/h3>\n<ul>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/sDHczqDiYqhOIg6fi5L30g~~\/DB10035030EN.pdf\" target=\"_blank\" rel=\"noopener\">Data sheet: DB10035030EN.pdf<\/a><\/li>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/KmJns9KQShoEWsI0IVdq5A~~\/ZUE63634.pdf\" target=\"_blank\" rel=\"noopener\">UL approval: ZUE63634.pdf<\/a><\/li>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/CxCWIekVH18aSuA2B3_ugg~~\/CE10035030EN.pdf\" target=\"_blank\" rel=\"noopener\">CE declaration of conformity: CE10035030EN.pdf<\/a><\/li>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/DKfatcRsg5C-yomVDIjW0g~~\/UILCPRDOP17_10035030-1EN.pdf\" target=\"_blank\" rel=\"noopener\">CPR declaration of performance: UILCPRDOP17_10035030-1EN.pdf<\/a><\/li>\n<\/ul>\n<details>\n<summary>Manufacturer notes<\/summary>\n<ul>\n<li>Inductance and operating capacitance are neither defined nor controlled electrical parameters. The specified values were determined by calculation and may deviate due to tolerances.<\/li>\n<li>Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.<\/li>\n<li>Photographs and graphics are not to scale and do not represent detailed images of the respective products.<\/li>\n<li>The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.<\/li>\n<li>If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Supply lengths &amp; ordering conditions<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Minimum order quantity<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Order quantity interval<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer individual cut lengths<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer standard lengths<\/th>\n<td>50 \/ 500 \/ 1000 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/en\/de\/oelflex-classic-110-ch\/p\/10035095\" target=\"_blank\" rel=\"noopener\">Official LAPP product information, datasheet and certificates<\/a><\/p>\n<p>Manufacturer nominal values. Representative product image; construction, colour and dimensions may vary by article. Cable weights exclude packaging and reels. Shipping depends on packed weight and dimensions.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<p>Anschluss- und Steuerleitung; 5G4; U<sub>0<\/sub>\/U: 300\/500 V; HFFR; Aderidentifizierung: Nummern; Geschirmt; UL recognized; flexibel<\/p>\n<p>Zuschnitt: 10 \/ 20 \/ 50 \/ 100 m. Andere L\u00e4ngen auf Anfrage.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<p>Power and control cable; 5G4; U<sub>0<\/sub>\/U: 300\/500 V; HFFR; Core identification: Numbers; Shielded; UL recognized; Flexible<\/p>\n<p>Cut lengths: 10 \/ 20 \/ 50 \/ 100 m. Other lengths on request.<\/p>\n<\/div>","protected":false},"featured_media":23718,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[140],"product_cat":[34],"product_tag":[],"class_list":["post-23939","product","type-product","status-publish","has-post-thumbnail","product_brand-lapp","product_cat-steuer-und-anschlussleitungen","desktop-align-left","tablet-align-left","mobile-align-left","first","outofstock","sale","taxable","shipping-taxable","purchasable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product\/23939","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/comments?post=23939"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media\/23718"}],"wp:attachment":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media?parent=23939"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_brand?post=23939"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_cat?post=23939"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_tag?post=23939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}