{"id":53210,"date":"2026-10-20T01:11:43","date_gmt":"2026-10-20T01:11:43","guid":{"rendered":"https:\/\/shop.germansts.de\/?post_type=product&#038;p=53210"},"modified":"2026-10-20T09:40:23","modified_gmt":"2026-10-20T09:40:23","slug":"lapp-oelflex-solar-xlr-e-swr-1-x-240-wh-rd-85120914","status":"publish","type":"product","link":"https:\/\/shop.germansts.de\/en\/product\/lapp-oelflex-solar-xlr-e-swr-1-x-240-wh-rd-85120914\/","title":{"rendered":"LAPP \u00d6LFLEX\u00ae SOLAR XLR-E SWR 1 X 240 WH\/RD \u2013 85120914"},"content":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<h2>\u00d6LFLEX\u00ae SOLAR XLR-E SWR 1 X 240 WH\/RD<\/h2>\n<p>Solarleitung; 1X240; rot; U<sub>0<\/sub>\/U: 1\/1 kV; elektronenstrahlvernetztes Polymer-Compound; feste Verlegung; Halogenfrei<\/p>\n<p>Zuschnittl\u00e4ngen: 10, 20, 50 und 100 m. Andere L\u00e4ngen auf Anfrage.<\/p>\n<h3>Vorteile<\/h3>\n<ul>\n<li>Nach 2\u202fPfG\u202f2962 durch T\u00dcV Rheinland gepr\u00fcfte Solarleitung, die dauerhaft Feuchtigkeit, Salzspr\u00fchnebel, Schimmel und UV\u2011Strahlung standh\u00e4lt und dadurch einen zuverl\u00e4ssigen Betrieb erm\u00f6glicht.<\/li>\n<li>Halogenfreie Aderisolier- und Mantelmischung zur Einhaltung besonderer Brandschutzanforderungen.<\/li>\n<li>Vernetzte Isolier- und Mantelwerkstoffe beg\u00fcnstigen die Langlebigkeit bei hohen Temperaturen oder bei hoher Strombelastung, sichern eine hohe Spannungsfestigkeit und eine hohe Kurzschlusstemperatur.<\/li>\n<li>IEC-Zertifizierung erlaubt internationale Verwendung des Produkts in L\u00e4ndern, in denen IEC-Standards gelten.<\/li>\n<li>In drei verschiedenen Au\u00dfenmantelfarben zur \u00e4u\u00dferen Unterscheidbarkeit des DC-Leiters erh\u00e4ltlich.<\/li>\n<\/ul>\n<h3>Anwendungsbereiche<\/h3>\n<ul>\n<li>Zur ungesch\u00fctzten Verbindung von Solarmodul und Wechselrichter in geerdeten und nicht geerdeten Photovoltaikanlagen nach IEC 62930 und T\u00dcV Rheinland 2 PfG 2962.<\/li>\n<li>Zur Verbindung von Solarmodulen untereinander. <\/li>\n<li>Speziell f\u00fcr den Einsatz in schwimmenden Photovoltaikanlagen auf Seen, Stauseen und Ozeanen.<\/li>\n<li>F\u00fcr Gleichstromanwendungen bis 1,8 kV.<\/li>\n<li>Zur festen Verlegung und gelegentlichen Bewegung, ggf. frei h\u00e4ngend. <\/li>\n<li>In geschlossenen Installationskan\u00e4len, unter Putz sowie in Ger\u00e4ten verlegbar. <\/li>\n<li>F\u00fcr den Au\u00dfenbereich geeignet.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<details>\n<summary>Allgemeine Informationen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Marke<\/th>\n<td>\u00d6LFLEX\u00ae<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Produkttyp<\/th>\n<td>Solarleitung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Gewicht<\/th>\n<td>2690 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Kupferzahl<\/th>\n<td>2304 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Zolltarifnummer<\/th>\n<td>85446010<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Elektrische Kennwerte<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nennspannung<\/th>\n<td>U0\/U: 1\/1 kV AC rms nach IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Betriebsspannung (max.)<\/th>\n<td>1,8 kV DC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pr\u00fcfspannung<\/th>\n<td>6.5 kV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produktaufbau<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Harmonisierte Bauart<\/th>\n<td>H1Z2Z2-K<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitungsabmessung<\/th>\n<td>1X240<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiternennquerschnitt (metrisch)<\/th>\n<td>240 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitermaterial<\/th>\n<td>verzinntes Kupfer<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Einschlie\u00dflich Schutzleiter<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Anzahl Adern<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nennaussendurchmesser<\/th>\n<td>28,4 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitungsform<\/th>\n<td>rund<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial der Aderisolation<\/th>\n<td>elektronenstrahlvernetztes Polymer-Compound<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Isolationsfarbe<\/th>\n<td>wei\u00df<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Au\u00dfenmantels<\/th>\n<td>elektronenstrahlvernetztes Polymer-Compound<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Au\u00dfenmantelfarbe<\/th>\n<td>rot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produkteigenschaften<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Einsatzgebiet<\/th>\n<td>feste Verlegung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius, festverlegt<\/th>\n<td>5 x Au\u00dfendurchmesser<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius in mm, festverlegt<\/th>\n<td>142 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt<\/th>\n<td>-40 \u00b0C bis 90 \u00b0C max. Leitertemperatur<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt max<\/th>\n<td>90 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, gelegentlich bewegt<\/th>\n<td>-25 \u00b0C bis 90 \u00b0C max. Leitertemperatur<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, gelegentlich bewegt max<\/th>\n<td>90 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, gelegentlich bewegt min<\/th>\n<td>-25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur bei Lagerung max.<\/th>\n<td>40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrigkeit nach<\/th>\n<td>IEC 60332-1-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig nach<\/th>\n<td>EN 50618<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Witterungsbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Witterungsbest\u00e4ndig nach<\/th>\n<td>EN 50618<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozonbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogenfrei<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u00d6lbest\u00e4ndig<\/th>\n<td>Nein<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Zertifizierungen und Normen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE gekennzeichnet<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">HAR-zertifiziert<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">T\u00dcV zertifiziert<\/th>\n<td>Ja<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Herstellerhinweise<\/summary>\n<ul>\n<li>Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie  &#8211; soweit verf\u00fcgbar und zur Ver\u00f6ffentlichung freigegeben- auf Anfrage.<\/li>\n<li>Die Fotografien und Grafiken sind nicht ma\u00dfst\u00e4blich und keine detailgetreuen Abbildungen der jeweiligen Produkte.<\/li>\n<li>Sofern anwendbar, handelt es sich um den Vollmetallpreis ohne Zuschl\u00e4ge und MwSt. Verkauf nur an Firmenkunden.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Lieferl\u00e4ngen &#038; Bestellbedingungen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Mindestbestellmenge<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Bestellintervall<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Individueller Zuschnitt beim Hersteller<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hersteller-Standardl\u00e4ngen<\/th>\n<td>500 \/ 1000 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/de\/de\/oelflex-solar-xlr-e-swr\/p\/85120914\" target=\"_blank\" rel=\"noopener\">Offizielle LAPP Produktinformationen, Datenblatt und Zertifikate<\/a><\/p>\n<p>Hersteller-Nennwerte. Produktabbildung repr\u00e4sentativ; Bauform, Farbe und Abmessungen k\u00f6nnen je Artikel abweichen. Gewichte gelten f\u00fcr das Kabel ohne Verpackung und Trommel. Versand nach verpacktem Gewicht und Ma\u00dfen.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<h2>\u00d6LFLEX\u00ae SOLAR XLR-E SWR 1 X 240 WH\/RD<\/h2>\n<p>Solar cable; 1X240; red; U<sub>0<\/sub>\/U: 1\/1 kV; Electron beam cross-linked polymer compound; Fixed installation; Halogen-free<\/p>\n<p>Cut lengths: 10, 20, 50 and 100 m. Other lengths on request.<\/p>\n<h3>Benefits<\/h3>\n<ul>\n<li>Solar cable tested by T\u00dcV Rheinland in accordance with 2 PfG 2962, which permanently withstands moisture, salt spray, mould and UV radiation, thereby ensuring reliable operation.<\/li>\n<li>Halogen-free core insulation and sheath compound to comply with special fire safety requirements.<\/li>\n<li>Cross-linked insulation and sheathing materials promote longevity at high temperatures or at high current loads, and ensure a high dielectric strength and a high short circuit temperature.<\/li>\n<li>IEC certification allows international use of the product in countries in which the IEC standards are applicable.<\/li>\n<li>Available in three different outer sheath colours so that the DC conductor can be identified externally.<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n<li>For the unprotected connection of solar modules and inverters in earthed and unearthed photovoltaic systems in accordance with IEC 62930 and T\u00dcV Rheinland 2 PfG 2962.<\/li>\n<li>For interconnecting solar modules. <\/li>\n<li>Specially designed for use in floating photovoltaic systems on lakes, reservoirs and oceans.<\/li>\n<li>For direct current applications up to 1.8 kV.<\/li>\n<li>For fixed installation and occasional movement, if necessary freely hanging. <\/li>\n<li>Can be installed in closed installation ducts, under plaster and in devices. <\/li>\n<li>Suitable for outdoor use.<\/li>\n<\/ul>\n<h2>Technical specifications<\/h2>\n<details>\n<summary>General information<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Brand<\/th>\n<td>\u00d6LFLEX\u00ae<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Product type<\/th>\n<td>Solar cable<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Weight<\/th>\n<td>2690 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Copper index<\/th>\n<td>2304 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">customs code<\/th>\n<td>85446010<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Electrical parameters<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nominal voltage<\/th>\n<td>U0\/U: 1\/1 kV AC rms according to IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Operating voltage (max.)<\/th>\n<td>1,8 kV DC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Test voltage<\/th>\n<td>6.5 kV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product design<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Harmonised design<\/th>\n<td>H1Z2Z2-K<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cable dimensions<\/th>\n<td>1X240<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal conductor cross-section (metric)<\/th>\n<td>240 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor material<\/th>\n<td>Tin-plated copper<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Including protective earth<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Number of cores<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal outer diameter<\/th>\n<td>28.4 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cable shape<\/th>\n<td>Round<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core insulation basic material<\/th>\n<td>Electron beam cross-linked polymer compound<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Insulation colour<\/th>\n<td>white<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Basic material of outer sheath<\/th>\n<td>Electron beam cross-linked polymer compound<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Outer sheath colour<\/th>\n<td>red<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product features<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Application area<\/th>\n<td>Fixed installation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius, stationary<\/th>\n<td>5 x outer diameter<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius in mm, fixed installation<\/th>\n<td>142 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation<\/th>\n<td>-40 \u00b0C to 90 \u00b0C max. conductor temperature<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation max<\/th>\n<td>90 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">max. conductor temperature, occasionally moved<\/th>\n<td>-25 \u00b0C to 90 \u00b0C max. conductor temperature<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, occasionally moved max<\/th>\n<td>90 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, occasionally moved min<\/th>\n<td>-25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. storage temperature<\/th>\n<td>40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame-retardant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame retardance according to<\/th>\n<td>IEC 60332-1-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant according to<\/th>\n<td>EN 50618<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Weather-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Weather-resistant according to<\/th>\n<td>EN 50618<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozone-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogen-free<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil-resistant<\/th>\n<td>No<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Certifications and standards<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE marking<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">HAR certified<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">T\u00dcV certified<\/th>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Manufacturer notes<\/summary>\n<ul>\n<li>Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.<\/li>\n<li>Photographs and graphics are not to scale and do not represent detailed images of the respective products.<\/li>\n<li>If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Supply lengths &#038; ordering conditions<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Minimum order quantity<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Order quantity interval<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer individual cut lengths<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer standard lengths<\/th>\n<td>500 \/ 1000 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/en\/de\/oelflex-solar-xlr-e-swr\/p\/85120914\" target=\"_blank\" rel=\"noopener\">Official LAPP product information, datasheet and certificates<\/a><\/p>\n<p>Manufacturer nominal values. Representative product image; construction, colour and dimensions may vary by article. Cable weights exclude packaging and reels. Shipping depends on packed weight and dimensions.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<p>Solarleitung; 1X240; rot; U<sub>0<\/sub>\/U: 1\/1 kV; elektronenstrahlvernetztes Polymer-Compound; feste Verlegung; Halogenfrei<\/p>\n<p>Zuschnitt: 10 \/ 20 \/ 50 \/ 100 m. Andere L\u00e4ngen auf Anfrage.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<p>Solar cable; 1X240; red; U<sub>0<\/sub>\/U: 1\/1 kV; Electron beam cross-linked polymer compound; Fixed installation; Halogen-free<\/p>\n<p>Cut lengths: 10 \/ 20 \/ 50 \/ 100 m. Other lengths on request.<\/p>\n<\/div>","protected":false},"featured_media":53058,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[140],"product_cat":[60],"product_tag":[],"class_list":["post-53210","product","type-product","status-publish","has-post-thumbnail","product_brand-lapp","product_cat-solarkabel-dc","desktop-align-left","tablet-align-left","mobile-align-left","first","outofstock","sale","taxable","shipping-taxable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product\/53210","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/comments?post=53210"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media\/53058"}],"wp:attachment":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media?parent=53210"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_brand?post=53210"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_cat?post=53210"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_tag?post=53210"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}