{"id":55368,"date":"2026-10-20T01:38:06","date_gmt":"2026-10-20T01:38:06","guid":{"rendered":"https:\/\/shop.germansts.de\/?post_type=product&#038;p=55368"},"modified":"2026-10-20T01:38:45","modified_gmt":"2026-10-20T01:38:45","slug":"lapp-na2xsfl2y-1x185-rm-25-12-20kv-38107252","status":"publish","type":"product","link":"https:\/\/shop.germansts.de\/en\/product\/lapp-na2xsfl2y-1x185-rm-25-12-20kv-38107252\/","title":{"rendered":"LAPP NA2XS(FL)2Y 1X185 RM\/25 12\/20kV \u2013 38107252"},"content":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<h2>NA2XS(FL)2Y 1X185 RM\/25 12\/20kV<\/h2>\n<p>Mittelspannungskabel; 1&#215;185 RM; U<sub>0<\/sub>\/U: 12\/20 kV; Aluminium; PE; Geschirmt; VDE zertifiziert; feste Verlegung<\/p>\n<p>Zuschnittl\u00e4ngen: 10, 20, 50 und 100 m. Andere L\u00e4ngen auf Anfrage.<\/p>\n<h3>Vorteile<\/h3>\n<ul>\n<li>VDE-zertifizierte Leitung mit Pr\u00fcfzeichen \u25c1VDE\u25b7 f\u00fcr gepr\u00fcfte Sicherheit und Qualit\u00e4t nach VDE 0276-620.<\/li>\n<li>Robust bei Verlegung und Betrieb dank widerstandsf\u00e4higem PE-Au\u00dfenmantel.<\/li>\n<li>Mit zus\u00e4tzlicher Bandierung zum Schutz vor dem Eintreten von Wasser in L\u00e4ngsrichtung nach mechanischer Besch\u00e4digung.<\/li>\n<li>Mit Aluminium-PE-Schichtenmantel zum Schutz vor dem Eintreten von Wasser in Querrichtung nach mechanischer Besch\u00e4digung.<\/li>\n<li>Vernetzte Leitschichten \u00fcber und unter der Aderisolation verhindern Teilentladungen und erm\u00f6glichen konstante Betriebssicherheit.<\/li>\n<li>In Leiterquerschnitten bis 500 mm2 erh\u00e4ltlich.<\/li>\n<li>In den Spannungsklassen 6\/10 (12) kV, 12\/20 (24) kV und 18\/30 (36) kV erh\u00e4ltlich.<\/li>\n<\/ul>\n<h3>Anwendungsbereiche<\/h3>\n<ul>\n<li>F\u00fcr die Energieverteilung in Mittelspannungsnetzen geeignet.<\/li>\n<li>Geeignet f\u00fcr den Einsatz in AC- und DC-Ladeinfrastrukturen der Elektromobilit\u00e4t.<\/li>\n<li>Zur festen Verlegung in Wasser, Luft und Erde. Im Erdreich betr\u00e4gt die Mindestverlegetiefe ohne zus\u00e4tzlichen, angemessenen Untergrundschutz 0,6 m, unter Fahrbahnen mindestens 0,8 m (gem\u00e4\u00df HD 620\/VDE 0276-620 Teil 10-C (Punkt 4)).<\/li>\n<li>Auch zur Verlegung in Innenr\u00e4umen sowie geschlossenen Installationskan\u00e4len f\u00fcr EVU-, Industrie- und Verteilernetze geeignet, jedoch nicht flammwidrig nach IEC 60332-1-2.<\/li>\n<li>Aufgrund des PE-Au\u00dfenmantels f\u00fcr starke mechanische Beanspruchung geeignet.<\/li>\n<li>F\u00fcr den Au\u00dfenbereich geeignet.<\/li>\n<li>Einsatz bei bis zu \u201140 \u00b0C m\u00f6glich.<\/li>\n<\/ul>\n<h3>Produkthinweise<\/h3>\n<ul>\n<li>Handels-Produkt, kein LAPP-Produkt.<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<details>\n<summary>Allgemeine Informationen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Produkttyp<\/th>\n<td>Mittelspannungskabel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Gewicht<\/th>\n<td>1474 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Kupferzahl<\/th>\n<td>283 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Aluminiumzahl<\/th>\n<td>536.5 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Industrie Segment<\/th>\n<td>Stromnetze<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Zolltarifnummer<\/th>\n<td>85446090<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Elektrische Kennwerte<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nennspannung<\/th>\n<td>U0\/U: 12\/20 kV AC rms nach IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Pr\u00fcfspannung<\/th>\n<td>30 kV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Strombelastbarkeit nach<\/th>\n<td>VDE 0276-620<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. Leiterwiderstand bei 20 \u00b0C<\/th>\n<td>0,164 \u03a9\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produktaufbau<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">N-Deutsche Normkabel<\/th>\n<td>NA2XS(FL)2Y<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiter Anzahl\/Gr\u00f6\u00dfe<\/th>\n<td>1&#215;185 RM\/25<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiternennquerschnitt (metrisch)<\/th>\n<td>185 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitermaterial<\/th>\n<td>Aluminium<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiteraufbau<\/th>\n<td>IEC 60228 Klasse 2: mehrdr\u00e4htig<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiterform<\/th>\n<td>rund<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiter Abk\u00fcrzung<\/th>\n<td>1&#215;185 RM<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Anzahl Adern<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Geschirmt<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Art des Gesamtschirm<\/th>\n<td>Kupferdr\u00e4hte mit Kupferquerleitwendel<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Min. Aussendurchmesser<\/th>\n<td>35 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. Aussendurchmesser<\/th>\n<td>41 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitungsform<\/th>\n<td>rund<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial der Aderisolation<\/th>\n<td>Vernetztes Polyethylen<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial der Aderisolation, Kurzform<\/th>\n<td>XLPE<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Au\u00dfenmantels<\/th>\n<td>Polyethylen<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial des Au\u00dfenmantels, Kurzform<\/th>\n<td>PE<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Au\u00dfenmantelfarbe<\/th>\n<td>schwarz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produkteigenschaften<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Einsatzgebiet<\/th>\n<td>feste Verlegung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Erdverlegbar<\/th>\n<td>direkt; im Kabelgraben; im Schutzrohr<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius, festverlegt<\/th>\n<td>15 x Au\u00dfendurchmesser<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius in mm, festverlegt<\/th>\n<td>615 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt<\/th>\n<td>-40 \u00b0C bis 90 \u00b0C max. Leitertemperatur<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt max<\/th>\n<td>90 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Montagetemperatur min.<\/th>\n<td>-20 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrig<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig nach<\/th>\n<td>EN 50525-1 (Leitungen mit schwarzem Mantel sind f\u00fcr dauerhaften Einsatz im Freien geeignet)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogenfrei<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogenfreiheit nach<\/th>\n<td>IEC 60754-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u00d6lbest\u00e4ndig<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">LABS-frei<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">L\u00e4ngswasserdicht<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Querwasserdicht<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Wasserbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Zertifizierungen und Normen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE gekennzeichnet<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">VDE zertifiziert<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Produktnorm VDE<\/th>\n<td>VDE 0276-620<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrigkeit nach UN\/ECE-R118 getestet<\/th>\n<td>Nein<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<h3>Datenbl\u00e4tter und Zertifikate<\/h3>\n<ul>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/7wn2cuFqSQIMKCuko4VG2g~~\/DB38107624DE.pdf\" target=\"_blank\" rel=\"noopener\">Datenblatt: DB38107624DE.pdf<\/a><\/li>\n<\/ul>\n<details>\n<summary>Herstellerhinweise<\/summary>\n<ul>\n<li>Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie  &#8211; soweit verf\u00fcgbar und zur Ver\u00f6ffentlichung freigegeben- auf Anfrage.<\/li>\n<li>Die Fotografien und Grafiken sind nicht ma\u00dfst\u00e4blich und keine detailgetreuen Abbildungen der jeweiligen Produkte.<\/li>\n<li>Sofern anwendbar, handelt es sich um den Vollmetallpreis ohne Zuschl\u00e4ge und MwSt. Verkauf nur an Firmenkunden.<\/li>\n<li>Handels-Produkt, kein LAPP-Produkt.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Lieferl\u00e4ngen &#038; Bestellbedingungen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Mindestbestellmenge<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Bestellintervall<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Individueller Zuschnitt beim Hersteller<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hersteller-Standardl\u00e4ngen<\/th>\n<td>500 \/ 1000 \/ 2000 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/de\/de\/na2xs-fl-2y\/p\/38107252\" target=\"_blank\" rel=\"noopener\">Offizielle LAPP Produktinformationen, Datenblatt und Zertifikate<\/a><\/p>\n<p>Hersteller-Nennwerte. Produktabbildung repr\u00e4sentativ; Bauform, Farbe und Abmessungen k\u00f6nnen je Artikel abweichen. Gewichte gelten f\u00fcr das Kabel ohne Verpackung und Trommel. Versand nach verpacktem Gewicht und Ma\u00dfen.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<h2>NA2XS(FL)2Y 1X185 RM\/25 12\/20kV<\/h2>\n<p>Medium-voltage cable; 1&#215;185 RM; U<sub>0<\/sub>\/U: 12\/20 kV; Aluminium; PE; Shielded; VDE certified; Fixed installation<\/p>\n<p>Cut lengths: 10, 20, 50 and 100 m. Other lengths on request.<\/p>\n<h3>Benefits<\/h3>\n<ul>\n<li>VDE-certified cable with \u25c1VDE\u25b7 testing mark for proven reliability and quality according to VDE 0276-620.<\/li>\n<li>Robust during installation and operation thanks to durable PE outer sheath.<\/li>\n<li>With additional wrapping to protect against water penetration in the longitudinal direction after mechanical damage.<\/li>\n<li>With aluminium PE laminated sheath to protect against water penetration in the lateral direction after mechanical damage.<\/li>\n<li>Cross-linked conductive layers above and below the core insulation prevent partial discharges and enable constant operational safety.<\/li>\n<li>Available in conductor cross-sections up to 500 mm2.<\/li>\n<li>Available in voltage classes 6\/10 (12) kV, 12\/20 (24) kV and 18\/30 (36) kV.<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n<li>Suitable for energy distribution in medium-voltage networks.<\/li>\n<li>Suitable for use in AC and DC charging infrastructures for electromobility.<\/li>\n<li>For fixed installation in water, air and soil. In the ground, the minimum installation depth without additional, suitable underground protection is 0.6 m, and at least 0.8 m under roads (according to HD 620\/VDE 0276-620 Part 10-C (point 4)).<\/li>\n<li>Also suitable for installation indoors and in closed installation ducts for energy supplier, industrial and distribution networks, but not flame-retardant according to IEC 60332-1-2.<\/li>\n<li>Suitable for high mechanical stress due to the PE outer sheath.<\/li>\n<li>Suitable for outdoor use.<\/li>\n<li>Use at temperatures down to -40\u00b0C possible.<\/li>\n<\/ul>\n<h3>Product notes<\/h3>\n<ul>\n<li>Trade product, not a LAPP product.<\/li>\n<\/ul>\n<h2>Technical specifications<\/h2>\n<details>\n<summary>General information<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Product type<\/th>\n<td>Medium-voltage cable<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Weight<\/th>\n<td>1474 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Copper index<\/th>\n<td>283 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Aluminium index<\/th>\n<td>536.5 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Industry segment<\/th>\n<td>Power Grids<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">customs code<\/th>\n<td>85446090<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Electrical parameters<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nominal voltage<\/th>\n<td>U0\/U: 12\/20 kV AC rms according to IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Test voltage<\/th>\n<td>30 kV<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Current rating according to<\/th>\n<td>VDE 0276-620<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. conductor resistance at 20\u00b0C<\/th>\n<td>0.164 \u03a9\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product design<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">N-German standard cables<\/th>\n<td>NA2XS(FL)2Y<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor number\/size<\/th>\n<td>1&#215;185 RM\/25<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal conductor cross-section (metric)<\/th>\n<td>185 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor material<\/th>\n<td>Aluminium<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor design<\/th>\n<td>IEC 60228 class 2: multi-wire<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor shape<\/th>\n<td>Round<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor abbreviation<\/th>\n<td>1&#215;185 RM<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Number of cores<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Shielded<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Type of overall screening<\/th>\n<td>Copper wires with cross-conductor copper spiral<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Min. outer diameter<\/th>\n<td>35 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. outer diameter<\/th>\n<td>41 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cable shape<\/th>\n<td>Round<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core insulation basic material<\/th>\n<td>Cross-linked polyethylene<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core insulation basic material, short form<\/th>\n<td>XLPE<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Basic material of outer sheath<\/th>\n<td>Polyethylene<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Basic material of outer sheath, short form<\/th>\n<td>PE<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Outer sheath colour<\/th>\n<td>black<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product features<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Application area<\/th>\n<td>Fixed installation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Suitable for underground installation<\/th>\n<td>direct; in cable trench; in protective cable conduit<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius, stationary<\/th>\n<td>15 x outer diameter<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius in mm, fixed installation<\/th>\n<td>615 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation<\/th>\n<td>-40 \u00b0C to 90 \u00b0C max. conductor temperature<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation max<\/th>\n<td>90 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Installation temperature min.<\/th>\n<td>-20 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame-retardant<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant according to<\/th>\n<td>EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogen-free<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogen-free according to<\/th>\n<td>IEC 60754-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil-resistant<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">PWIS-free<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Longitudinally watertight<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Laterally watertight<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Water-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Certifications and standards<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE marking<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">VDE certified<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Product standard VDE<\/th>\n<td>VDE 0276-620<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame retardance tested according to UN\/ECE-R118<\/th>\n<td>No<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<h3>Datasheets and certificates<\/h3>\n<ul>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/iGktUGcwvvaR1jCrsBOqWw~~\/DB38107624EN.pdf\" target=\"_blank\" rel=\"noopener\">Data sheet: DB38107624EN.pdf<\/a><\/li>\n<\/ul>\n<details>\n<summary>Manufacturer notes<\/summary>\n<ul>\n<li>Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.<\/li>\n<li>Photographs and graphics are not to scale and do not represent detailed images of the respective products.<\/li>\n<li>If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.<\/li>\n<li>Trade product, not a LAPP product.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Supply lengths &#038; ordering conditions<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Minimum order quantity<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Order quantity interval<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer individual cut lengths<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer standard lengths<\/th>\n<td>500 \/ 1000 \/ 2000 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/en\/de\/na2xs-fl-2y\/p\/38107252\" target=\"_blank\" rel=\"noopener\">Official LAPP product information, datasheet and certificates<\/a><\/p>\n<p>Manufacturer nominal values. Representative product image; construction, colour and dimensions may vary by article. Cable weights exclude packaging and reels. Shipping depends on packed weight and dimensions.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<p>Mittelspannungskabel; 1&#215;185 RM; U<sub>0<\/sub>\/U: 12\/20 kV; Aluminium; PE; Geschirmt; VDE zertifiziert; feste Verlegung<\/p>\n<p>Zuschnitt: 10 \/ 20 \/ 50 \/ 100 m. Andere L\u00e4ngen auf Anfrage.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<p>Medium-voltage cable; 1&#215;185 RM; U<sub>0<\/sub>\/U: 12\/20 kV; Aluminium; PE; Shielded; VDE certified; Fixed installation<\/p>\n<p>Cut lengths: 10 \/ 20 \/ 50 \/ 100 m. Other lengths on request.<\/p>\n<\/div>","protected":false},"featured_media":55322,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[140],"product_cat":[31],"product_tag":[],"class_list":["post-55368","product","type-product","status-publish","has-post-thumbnail","product_brand-lapp","product_cat-niederspannungs-energiekabel","desktop-align-left","tablet-align-left","mobile-align-left","first","outofstock","taxable","shipping-taxable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product\/55368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/comments?post=55368"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media\/55322"}],"wp:attachment":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media?parent=55368"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_brand?post=55368"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_cat?post=55368"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_tag?post=55368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}