{"id":57398,"date":"2026-10-20T02:01:47","date_gmt":"2026-10-20T02:01:47","guid":{"rendered":"https:\/\/shop.germansts.de\/?post_type=product&#038;p=57398"},"modified":"2026-10-20T09:42:50","modified_gmt":"2026-10-20T09:42:50","slug":"lapp-unirail-s-50264-3-1-600v-m-fr-1x95-15382113","status":"publish","type":"product","link":"https:\/\/shop.germansts.de\/en\/product\/lapp-unirail-s-50264-3-1-600v-m-fr-1x95-15382113\/","title":{"rendered":"LAPP UNIRAIL S 50264-3-1 600V M FR 1X95 \u2013 15382113"},"content":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<h2>UNIRAIL S 50264-3-1 600V M FR 1X95<\/h2>\n<p>Bahnleitung; 1X95; EN 50264-3-1; Typ M; U<sub>0<\/sub>\/U: 0,6\/1 kV; -40 &#8211; 90 \u00b0C; Halogenfreie Mischung; ; rot<\/p>\n<p>Lieferl\u00e4ngen und Mindestbestellmengen sind eingeschr\u00e4nkt. Bitte ein individuelles Angebot anfragen.<\/p>\n<h3>Vorteile<\/h3>\n<ul>\n<li>F\u00fcr den Schutz von Personen und Sachg\u00fctern.<\/li>\n<li>Isolationserhalt bis zu 120 Minuten unter Einwirkung von Feuer (Klassifikation PH120 nach DIN EN 50200). Gew\u00e4hrleistet den Funktionserhalt und die Energieversorgung im Notfall.<\/li>\n<li>Normenkonform einsetzbar in Schienenfahrzeugen: Anforderungen an die Brandsicherheit und den Leitungsaufbau gem\u00e4\u00df DIN EN 50264-3-1, Typ M; Brandverhalten gem\u00e4\u00df DIN EN 45545-2, Gef\u00e4hrdungsstufe HL3.<\/li>\n<li>Vernetzter Isolierwerkstoff beg\u00fcnstigt die Langlebigkeit bei hohen Temperaturen oder bei hoher Strombelastung und sichert eine hohe Spannungsfestigkeit.<\/li>\n<li>Halogenfreie und hoch flammwidrige Materialien reduzieren die Gefahr von Brandfortleitung, hoher Rauchdichte und toxischen Rauchgasen im Brandfall.<\/li>\n<li>Platzsparend durch reduzierte Wanddicken.<\/li>\n<\/ul>\n<h3>Anwendungsbereiche<\/h3>\n<ul>\n<li>Zur Verdrahtung von sicherheitsrelevanten Komponenten in Schienenfahrzeugen.<\/li>\n<li>Typische Verwendungsbereiche sind Notstromkreise f\u00fcr Alarm, Beleuchtung und Kommunikationszwecke, die ihre Funktion im Brandfall f\u00fcr eine bestimmte Zeit aufrechterhalten m\u00fcssen.<\/li>\n<li>F\u00fcr die Verwendung in Schienenfahrzeugen, f\u00fcr feste Verlegung und f\u00fcr Anwendungen, bei denen begrenzt mit Bewegungen zu rechnen ist.<\/li>\n<li>Einsetzbar in trockenen, feuchten und speziell in rauen und \u00f6ligen Umgebungen.<\/li>\n<li>Vernetztes Polymer-Compound ist erh\u00f6ht best\u00e4ndig gegen \u00d6le, Kraftstoffe, Laugen und S\u00e4uren.<\/li>\n<\/ul>\n<h3>Produkthinweise<\/h3>\n<ul>\n<li>Weitere Technische Daten: Siehe Datenblatt oder auf Anfrage<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<details>\n<summary>Allgemeine Informationen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Produkttyp<\/th>\n<td>Bahnleitung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Gewicht<\/th>\n<td>871 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Kupferzahl<\/th>\n<td>912 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Industrie Segment<\/th>\n<td>Bahntechnik<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Zolltarifnummer<\/th>\n<td>85444995<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Elektrische Kennwerte<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nennspannung<\/th>\n<td>U0\/U: 0,6\/1 kV AC rms nach IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Maximale Betriebsspannung Um<\/th>\n<td>1,2 kV AC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Strombelastbarkeit nach<\/th>\n<td>EN 50355<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. Leiterwiderstand bei 20 \u00b0C<\/th>\n<td>0,21 \u03a9\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produktaufbau<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Leitungsbauartkurzzeichen f\u00fcr Schienenfahrzeuge<\/th>\n<td>Typ M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitungsabmessung<\/th>\n<td>1X95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiternennquerschnitt (metrisch)<\/th>\n<td>95 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitermaterial<\/th>\n<td>verzinntes Kupfer<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leiteraufbau<\/th>\n<td>IEC 60228 Klasse 5: feindr\u00e4htig<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Einschlie\u00dflich Schutzleiter<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Anzahl Adern<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Geschirmt<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Min. Durchmesser der Ader<\/th>\n<td>13,9 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. Durchmesser der Ader<\/th>\n<td>16,3 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Leitungsform<\/th>\n<td>rund<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Grundmaterial der Aderisolation<\/th>\n<td>Halogenfreie Mischung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Bewicklung Ader<\/th>\n<td>MICA-Tape<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Einzelader Farbe<\/th>\n<td>rot<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Einzelader Identifizierung<\/th>\n<td>Einfarbig<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Produkteigenschaften<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Einsatzgebiet<\/th>\n<td>feste Verlegung<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimaler Biegeradius, festverlegt<\/th>\n<td>4 x Au\u00dfendurchmesser<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt<\/th>\n<td>-40 \u00b0C bis 90 \u00b0C max. Leitertemperatur<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt max<\/th>\n<td>90 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperatur, fest verlegt min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrigkeit nach<\/th>\n<td>EN 50200; IEC 60332-1-2; IEC 60332-3-24<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Geringe Rauchgasdichte nach<\/th>\n<td>IEC 61034-2; EN 50264-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Geringe Toxizit\u00e4t der Brandgase nach<\/th>\n<td>EN 50264-1; EN 50305<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Korrosivit\u00e4t der Brandgase nach<\/th>\n<td>EN 50264-1; IEC 60754-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-best\u00e4ndig<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozonbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozonbest\u00e4ndig nach<\/th>\n<td>EN 50264-3-1, Methode B; EN 50305<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Chemisch best\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">S\u00e4urebest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">S\u00e4urebest\u00e4ndig nach<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Laugenbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Laugenbest\u00e4ndig nach<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogenfrei<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogenfreiheit nach<\/th>\n<td>IEC 60754-1; EN 60684-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u00d6lbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u00d6lbest\u00e4ndigkeit nach<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Kraftstoffbest\u00e4ndig<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Kraftstoffbest\u00e4ndig nach<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Zertifizierungen und Normen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE gekennzeichnet<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">VDE zertifiziert<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flammwidrigkeit nach UN\/ECE-R118 getestet<\/th>\n<td>Nein<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Brandschutz-gepr\u00fcft f\u00fcr Schienenfahrzeuge<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Brandschutz f\u00fcr Schienenfahrzeuge Gef\u00e4hrdungsstufe<\/th>\n<td>EN 45545-2 HL3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Norm f\u00fcr Schienenfahrzeuge<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<h3>Datenbl\u00e4tter und Zertifikate<\/h3>\n<ul>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/0NchD8A69aoXxqv0Jx9fUQ~~\/DB15382100EN.pdf\" target=\"_blank\" rel=\"noopener\">Datenblatt: DB15382100EN.pdf<\/a><\/li>\n<\/ul>\n<details>\n<summary>Herstellerhinweise<\/summary>\n<ul>\n<li>Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie  &#8211; soweit verf\u00fcgbar und zur Ver\u00f6ffentlichung freigegeben- auf Anfrage.<\/li>\n<li>Die Fotografien und Grafiken sind nicht ma\u00dfst\u00e4blich und keine detailgetreuen Abbildungen der jeweiligen Produkte.<\/li>\n<li>Sofern anwendbar, handelt es sich um den Vollmetallpreis ohne Zuschl\u00e4ge und MwSt. Verkauf nur an Firmenkunden.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Lieferl\u00e4ngen &amp; Bestellbedingungen<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Mindestbestellmenge<\/th>\n<td>500 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Bestellintervall<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Individueller Zuschnitt beim Hersteller<\/th>\n<td>Ja<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Hersteller-Standardl\u00e4ngen<\/th>\n<td>500 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/de\/de\/unirail-s-50264-3-1-600v-m-fr\/p\/15382113\" target=\"_blank\" rel=\"noopener\">Offizielle LAPP Produktinformationen, Datenblatt und Zertifikate<\/a><\/p>\n<p>Hersteller-Nennwerte. Produktabbildung repr\u00e4sentativ; Bauform, Farbe und Abmessungen k\u00f6nnen je Artikel abweichen. Gewichte gelten f\u00fcr das Kabel ohne Verpackung und Trommel. Versand nach verpacktem Gewicht und Ma\u00dfen.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<h2>UNIRAIL S 50264-3-1 600V M FR 1X95<\/h2>\n<p>Railway cable; 1X95; EN 50264-3-1; Type M; U<sub>0<\/sub>\/U: 0,6\/1 kV; -40 &#8211; 90 \u00b0C; Halogen-free compound; ; red<\/p>\n<p>Supply lengths and minimum order quantities are restricted. Please request an individual quotation.<\/p>\n<h3>Benefits<\/h3>\n<ul>\n<li>For the protection of people and property.<\/li>\n<li>Insulation integrity for up to 120 minutes under the effect of fire (classification PH120 according to DIN EN 50200). Guarantees functional integrity and power supply in the event of an emergency.<\/li>\n<li>Compliant with standards for use in railway vehicles: fire safety and cable design requirements in accordance with DIN EN 50264-3-1, type M; fire behaviour in accordance with DIN EN 45545-2, hazard level HL3.<\/li>\n<li>Cross-linked insulation material promotes longevity at high temperatures or with high current loads, and provides high dielectric strength.<\/li>\n<li>Halogen-free and highly flame retardant materials reduce the risk of flame propagation, high smoke density and toxic smoke in the event of a fire.<\/li>\n<li>Space-saving due to reduced wall thicknesses.<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n<li>For wiring safety-related components in railway vehicles.<\/li>\n<li>Typical application areas are emergency power circuits for alarm, lighting and communication purposes, which must maintain their function for a certain period of time in the event of a fire.<\/li>\n<li>For use in railway vehicles, for fixed installation and applications where limited movement is to be expected.<\/li>\n<li>Can be used in dry and damp conditions, and especially in harsh and oily environments.<\/li>\n<li>The cross-linked polymer compound is highly resistant to oils, fuels, alkalis and acids.<\/li>\n<\/ul>\n<h3>Product notes<\/h3>\n<ul>\n<li>Further technical data: See data sheet or on request<\/li>\n<\/ul>\n<h2>Technical specifications<\/h2>\n<details>\n<summary>General information<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Product type<\/th>\n<td>Railway cable<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Weight<\/th>\n<td>871 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Copper index<\/th>\n<td>912 kg\/km<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Industry segment<\/th>\n<td>Rolling Stock<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">customs code<\/th>\n<td>85444995<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Electrical parameters<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Nominal voltage<\/th>\n<td>U0\/U: 0,6\/1 kV AC rms according to IEC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Maximum operating voltage Um<\/th>\n<td>1,2 kV AC<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Current rating according to<\/th>\n<td>EN 50355<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. conductor resistance at 20\u00b0C<\/th>\n<td>0.21 \u03a9\/km<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product design<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Cable design abbreviations for railway vehicles<\/th>\n<td>Type M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cable dimensions<\/th>\n<td>1X95<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Nominal conductor cross-section (metric)<\/th>\n<td>95 mm\u00b2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor material<\/th>\n<td>Tin-plated copper<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Conductor design<\/th>\n<td>IEC 60228 class 5: fine-wire<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Including protective earth<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Number of cores<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Shielded<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Min. core diameter<\/th>\n<td>13.9 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Max. core diameter<\/th>\n<td>16.3 mm<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cable shape<\/th>\n<td>Round<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core insulation basic material<\/th>\n<td>Halogen-free compound<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Core wrapping<\/th>\n<td>MICA tape<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Single core colour<\/th>\n<td>red<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Single core identification<\/th>\n<td>Single-coloured<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Product features<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Application area<\/th>\n<td>Fixed installation<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Minimum bending radius, stationary<\/th>\n<td>4 x outer diameter<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation<\/th>\n<td>-40 \u00b0C to 90 \u00b0C max. conductor temperature<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation max<\/th>\n<td>90 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Temperature, fixed installation min<\/th>\n<td>-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame-retardant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame retardance according to<\/th>\n<td>EN 50200; IEC 60332-1-2; IEC 60332-3-24<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Low smoke density according to<\/th>\n<td>IEC 61034-2; EN 50264-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Low toxicity of combustion gases according to<\/th>\n<td>EN 50264-1; EN 50305<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Corrosiveness of combustion gases according to<\/th>\n<td>EN 50264-1; IEC 60754-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">UV-resistant<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozone-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Ozone-resistant according to<\/th>\n<td>EN 50264-3-1, method B; EN 50305<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Chemical resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Acid-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Acid-resistant according to<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Alkali-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Alkali-resistant according to<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogen-free<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Halogen-free according to<\/th>\n<td>IEC 60754-1; EN 60684-2<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Oil resistance according to<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Fuel-resistant<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Fuel-resistant according to<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<details>\n<summary>Certifications and standards<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">CE marking<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">VDE certified<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Flame retardance tested according to UN\/ECE-R118<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Fire protection tested for railway vehicles<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Fire protection for railway vehicles hazard level<\/th>\n<td>EN 45545-2 HL3<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Standard for railway vehicles<\/th>\n<td>EN 50264-3-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<h3>Datasheets and certificates<\/h3>\n<ul>\n<li><a href=\"https:\/\/contentmedia.lappcdn.com\/e\/lapp\/0NchD8A69aoXxqv0Jx9fUQ~~\/DB15382100EN.pdf\" target=\"_blank\" rel=\"noopener\">Data sheet: DB15382100EN.pdf<\/a><\/li>\n<\/ul>\n<details>\n<summary>Manufacturer notes<\/summary>\n<ul>\n<li>Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.<\/li>\n<li>Photographs and graphics are not to scale and do not represent detailed images of the respective products.<\/li>\n<li>If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.<\/li>\n<\/ul>\n<\/details>\n<details>\n<summary>Supply lengths &amp; ordering conditions<\/summary>\n<table>\n<tbody>\n<tr>\n<th scope=\"row\">Minimum order quantity<\/th>\n<td>500 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Order quantity interval<\/th>\n<td>0 M<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer individual cut lengths<\/th>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Manufacturer standard lengths<\/th>\n<td>500 M<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/details>\n<p><a href=\"https:\/\/www.lapp.com\/en\/de\/unirail-s-50264-3-1-600v-m-fr\/p\/15382113\" target=\"_blank\" rel=\"noopener\">Official LAPP product information, datasheet and certificates<\/a><\/p>\n<p>Manufacturer nominal values. Representative product image; construction, colour and dimensions may vary by article. Cable weights exclude packaging and reels. Shipping depends on packed weight and dimensions.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div class=\"gsts-lang-de notranslate\" lang=\"de\" data-no-translation>\n<p>Bahnleitung; 1X95; EN 50264-3-1; Typ M; U<sub>0<\/sub>\/U: 0,6\/1 kV; -40 &#8211; 90 \u00b0C; Halogenfreie Mischung; ; rot<\/p>\n<p>Lieferl\u00e4ngen und Mindestmenge auf Anfrage.<\/p>\n<\/div>\n<div class=\"gsts-lang-en notranslate\" lang=\"en\" data-no-translation>\n<p>Railway cable; 1X95; EN 50264-3-1; Type M; U<sub>0<\/sub>\/U: 0,6\/1 kV; -40 &#8211; 90 \u00b0C; Halogen-free compound; ; red<\/p>\n<p>Supply lengths and minimum quantity on request.<\/p>\n<\/div>","protected":false},"featured_media":57403,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[140],"product_cat":[68],"product_tag":[],"class_list":["post-57398","product","type-product","status-publish","has-post-thumbnail","product_brand-lapp","product_cat-sonderleitungen-und-kundenspezifische-konfigurationen","desktop-align-left","tablet-align-left","mobile-align-left","first","outofstock","sale","taxable","shipping-taxable","product-type-variable"],"_links":{"self":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product\/57398","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/comments?post=57398"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media\/57403"}],"wp:attachment":[{"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/media?parent=57398"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_brand?post=57398"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_cat?post=57398"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shop.germansts.de\/en\/wp-json\/wp\/v2\/product_tag?post=57398"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}