Article specifications
| Part no. | 62686 |
|---|---|
| Item description | TRAYCONTROL® 300 grey 3 x 18 AWG |
| Nominal cross-section, approx. (mm²) | 0,96 |
| Outer diameter, approx. (mm) | 7,7 |
| Copper factor per km | 27,7 |
| Weight, approx. (kg/km) | 86,0 |
| Metres per packaging unit | 100, 500, 1000 |
| Custom cut lengths available | yes |
| EAN / GTIN | 4060892085741 |
| Customs tariff number | 85444995 |
Manufacturer technical information
Temperature range
fixed -25°C to +105°C
Nominal voltage
Test voltage core/core
Minimum bending radius
fixed 4x Outer-Ø
Cable Structure
- Copper wire tinned, finely stranded, AWG sizes
- Core insulation: see datasheet
- Core identification acc. to company specifications, colour coded
- Cores stranded in layers with optimal lay lengths
- Separator
- Outer sheath: Special-PVC
- Sheath colour: grey (RAL 7001)
- Length marking: in feet
Properties
- resistant to: oil
- for outdoor use
- the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
- flame-retardant acc. to CSA FT4
- oil-resistant acc. to UL Std. 13 No. 40, Oil Res I / Oil Res II
- Cold Bend Test acc. to UL Std. 13 No. 22
- Impact Test (-ER) acc. to UL Std. 13 No. 23
- Crushing Test (-ER) acc. to UL Std. 13 No. 24
- Vertical-Tray Flame Test (FT4) CSA-Std. C22.2 No. 2256
- certifications and approvals:
- EAC
- ECOLAB®
Notes
- Conductor sizes are based on the AWG measurement system, metric conductor sizes (mm²) are approximated and are for reference only
Application
- TRAYCONTROL® 300 is a flexible PVC data cable. The special combination of PLTC-ER and ITC-ER allows this cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79. Approved for open, unprotected installation in cable trays to the machine. Recommended applications: machine tools, control panels, control and instrumentation technology, production automation, cable ducts, and renewable energy. 22 – 16 AWG: resistant to UV radiation (SUN RES); 18 – 16 AWG: direct burial (DIR BUR). Only cables with 3 or more cores are rated for exposed run (ER).



Reviews