Article specifications
| Part no. | 21123 |
|---|---|
| Item description | PAAR-TRONIC-Li-2YCY grey 2 x 2 x 0,5 mm² |
| AWG, approx. | 20 |
| Outer diameter, approx. (mm) | 8 |
| Copper factor per km | 49,0 |
| Weight, approx. (kg/km) | 74,0 |
| Reaction to fire class | Eca |
| Metres per packaging unit | 100, 500, 1000 |
| Custom cut lengths available | yes |
| EAN / GTIN | 4060892097638 |
| Customs tariff number | 85444995 |
Manufacturer technical information
PVC data cable
Temperature range
flexible -5°C to +70°C
fixed -30°C to +80°C
fixed -30°C to +80°C
Peak operating voltage
250 V (not for high power current installation purposes)
Test voltage core/core
2000 V
Test voltage core/screen
1000 V
Conductor resistance at 20°C
0.22 mm²: max. 93.0 Ohm/km
0.34 mm²: max. 57.5 Ohm/km
0.5 mm²: max. 39.3 Ohm/km
0.34 mm²: max. 57.5 Ohm/km
0.5 mm²: max. 39.3 Ohm/km
Mutual capacitance core/core
at 800 Hz
2 - 4 pairs: approx. 72 pF/m
8 - 10 pairs: approx. 60 pF/m
2 - 4 pairs: approx. 72 pF/m
8 - 10 pairs: approx. 60 pF/m
Crosstalk attenuation
at 1 MHz, 50.00 dB
at 10 MHz, 40.00 dB
(approx. value)
at 10 MHz, 40.00 dB
(approx. value)
Inductance
approx. 0.66 mH/km
Coupling resistance
at 30 MHz, approx. 250 Ohm/km
Minimum bending radius
flexible 12x Outer-Ø
fixed 7.5x Outer-Ø
fixed 7.5x Outer-Ø
Cable Structure
- Copper wire bare, stranded
- Strand construction:
- 0.22 mm²: 7 x 0.2
- 0.34 mm²: 7 x 0.25
- 0.5 mm²: 7 x 0.3
- Core insulation: PE acc. to DIN VDE 0819-103 / DIN EN 50290-2-23 (compound type LD/MD)
- Core identification acc. to DIN 47100 (paired stranding), colour coded
- x = without protective conductor
- Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths
- Foil wrapping
- Drain wire, tinned copper
- Screen: braided screen of tinned copper wires, approx. coverage 85%
- Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2)
- Sheath colour: grey (RAL 7001)
- Length marking: in metres
Properties
- the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
- certifications and approvals:
- EAC
Notes
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
- PE-insulated data cable with twisted pairs, for interference-free transmission of data and signals over longer distances. The twisted-pair lay-up prevents electrical unbalances within the cable and this thus effectively suppresses cross-talking effects. The high transmission rates are particularly suitable for RS 422 and RS 485 interfaces; suitable for fixed installations in dry, damp and wet rooms, but not outdoors. EMC = Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.



Reviews