Article specifications
| Part no. | 11025147 |
|---|---|
| Item description | HELUPOWER® SOLARFLEX®-X H1Z2Z2-K UL black 1 x 4 mm² |
| AWG no. | 12 |
| Outer diameter, approx. (mm) | 6,3 - 6,7 |
| Copper factor per km | 38,4 |
| Weight, approx. (kg/km) | 66,8 |
| Metres per packaging unit | 1000 |
| Custom cut lengths available | yes |
| EAN / GTIN | 4060892542503 |
| Customs tariff number | 85446010 |
Manufacturer technical information
Cross-linked single core cable acc. to DIN VDE 0283-618 / DIN EN 50618, IEC 62930, UL-Std. 4703 (PV Wire)
Temperature range
fixed -40°C to +90°C
Permissible operating temperature of the conductor
+120°C
Nominal voltage
AC U0/U 1000/1000 V
DC U0/U 1500/1500 V
UL (PV) DC 2000 V
DC U0/U 1500/1500 V
UL (PV) DC 2000 V
Test voltage
6500 V
Minimum bending radius
fixed 5x Outer-Ø
Cable Structure
- Copper wire tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5, UL Std. 1581
- Core insulation: cross-linked compound
- x = without protective conductor
- Outer sheath: cross-linked compound
- Sheath colour: black
Properties
- resistant to: UV radiation, ozone, weathering effects, water
- for outdoor use
- direct burial
- halogen-free
Tests
- halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2, UL VW-1
- smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
- UV-resistant acc. to DIN VDE 0283-618 / DIN EN 50618 Appendix E
- ozone-resistant acc. to DIN VDE 0283-618 / DIN EN 50618
- weather-resistant acc. to DIN VDE 0283-618 / DIN EN 50618 Appendix E
- DC Voltage resistance of the insulation acc. to DIN VDE 0283-618 / DIN EN 50618 Tab. 2
- Sunlight Resistance (SUN RES) acc. to UL Std. 1581 Sec. 1200
- certifications and approvals:
- TÜV Rheinland
Application
- HELUPOWER® SOLARFLEX®-X H1Z2Z2-K is used for wiring solar modules. Suitable for direct burial; recommendation: laying in pipes. Not suitable for permanent installation in water. The maximum permissible DC voltage of the system in which the cable is installed must not exceed 1.8 kV. The cable is suitable for use in and on devices and systems with protective insulation (protection class II). Approbations acc. to EN, IEC and UL allow for an economical storekeeping and simplification of parts lists.