Power and control cable; 3G0.5; U0/U: 300/500 V; PVC; Core identification: Numbers; Shielded; Flexible
Benefits
- Weatherproof and therefore well suited for outdoor use.
- Space-saving due to reduced wall thicknesses.
- Doing away with the inner sheath results in lower weight and smaller outer diameters.
- Ideal protection against electromagnetic interference thanks to copper stranded shielding with a high degree of coverage.
- Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
Applications
- For universal use for wiring machine-internal and cross-plant control circuits.
- Cable design also suitable for torsion applications in wind turbines.
- For fixed installation and occasional movement without tensile strain.
- Can be used in dry and damp spaces.
- Suitable for medium mechanical stress.
- The PVC outer sheath is resistant to acids and alkalis and has limited oil resistance.
- Suitable for outdoor use.
Technical specifications
General information
| Brand | ÖLFLEX® |
|---|---|
| Product type | Power and control cable |
| Weight | 63 kg/km |
| Copper index | 43 kg/km |
| Industry segment | Agricultural & Farm Machinery; Assembly Machines; Construction Machinery; HVAC; Renewable Energy: Solar |
| customs code | 85444995 |
Electrical parameters
| Nominal voltage | U0/U: 300/500 V AC rms according to IEC |
|---|---|
| Test voltage core/core | 4 kV |
| Test voltage core/screening | 2 kV |
| Max. conductor resistance at 20°C | 39 Ω/km |
| Conductor/conductor operating capacitance (800Hz), approx. | 117 nF/km |
| Conductor/shielding operating capacitance (800Hz), approx. | 181 nF/km |
| Inductance (800 Hz), approx. | 0.722 mH/km |
Product design
| Cable dimensions | 3G0.5 |
|---|---|
| Nominal conductor cross-section (metric) | 0.5 mm² |
| Conductor material | Bare copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | Yes |
| Number of cores | 3 |
| Stranding type | Layered stranding |
| Wrapping over stranding | Plastic film |
| Shielded | Yes |
| Type of overall screening | Tin-plated copper braiding |
| With armouring | No |
| Nominal outer diameter | 6.1 mm |
| Cable shape | Round |
| Core insulation basic material | Polyvinylchloride |
| Core insulation basic material, short form | PVC |
| Basic material of outer sheath | Polyvinylchloride |
| Basic material of outer sheath, short form | PVC |
| Outer sheath colour | black |
| Core identification | Numbers |
| Conductor colour code | VDE 0293-1; EN 50334 |
Product features
| Application area | Flexible; Fixed installation; Torsion |
|---|---|
| For permanent bending | No |
| For torsional load | Yes |
| Minimum bending radius, stationary | 6 x outer diameter |
| Minimum bending radius in mm, fixed installation | 36.6 mm |
| Minimum bending radius, occasionally flexing | 20 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 122 mm |
| Torsion | for +/- 150 °/m and min. -20 °C up to 2000 Torsion cycles; for +/- 150 °/m and min. 5 °C up to 5000 Torsion cycles |
| Temperature, fixed installation | -40 °C to 80 °C max. conductor temperature |
| Temperature, fixed installation max | 80 °C |
| Temperature, fixed installation min | -40 °C |
| max. conductor temperature, occasionally moved | -5 °C to 70 °C max. conductor temperature |
| Temperature, occasionally moved max | 70 °C |
| Temperature, occasionally moved min | -5 °C |
| Flame-retardant | Yes |
| Flame retardance according to | IEC 60332-1-2 |
| UV-resistant | Yes |
| UV-resistant according to | DIN EN ISO 4892-2 method A; EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use) |
| Ozone-resistant | Yes |
| Ozone-resistant according to | EN 50396, method B |
| Chemical resistant | Yes |
| Halogen-free | No |
| Oil-resistant | No |
| PWIS-free | Yes |
| PWIS-free according to | VDMA 24364-B2-L |
Certifications and standards
| CE marking | Yes |
|---|---|
| EAC-certified | Yes |
| EAC certification number | ЕАЭС N RU Д-DE.АЮ64.В.00130/20 |
| VDE certified | No |
| DNV-certified | No |
| CPR fire class | Eca |
| Flame retardance tested according to UN/ECE-R118 | No |
| Ecolab certified | No |
Datasheets and certificates
- Data sheet: DB1136510EN.pdf
- CE declaration of conformity: CE1136510EN.pdf
- CPR declaration of performance: UILCPRDOP17_0012640-1EN.pdf
Manufacturer notes
- Inductance and operating capacitance are neither defined nor controlled electrical parameters. The specified values were determined by calculation and may deviate due to tolerances.
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.






Reviews
There are no reviews yet.