Benefits
- Easy handling and installation due to the flexible variant.
- Halogen-free and highly flame retardant materials reduce the risk of flame propagation, high smoke density and toxic smoke in the event of a fire.
- Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
- High electrical safety thanks to 4000 V test voltage.
- „GN/YE“ variants with green-yellow core insulation for connecting the protective earth conductor.
- Variants „RD“ and „WH“ with red or white core insulation in accordance with DIN EN 60445 for direct current systems.
Applications
- For structured building cabling for compliance with special fire protection requirements.
- For direct current applications in the low voltage range.
- For industrial plants in which power is distributed via a direct current grid.
- For universal use for wiring machine-internal and cross-plant control circuits.
- For fixed installation and occasional movement without tensile strain.
- Can be used in dry and damp spaces.
- Suitable for medium mechanical stress.
Technical specifications
General information
| Brand | ÖLFLEX® |
|---|---|
| Product type | DC power cable |
| Weight | 798 kg/km |
| Copper index | 672 kg/km |
| Industry segment | Renewable Energy: Solar |
| customs code | 85444995 |
Electrical parameters
| Nominal voltage | U0/U: 0,6/1 kV AC rms according to IEC; U0/U: 0,75/1,5 kV DC according to IEC |
|---|---|
| Test voltage | 4 kV |
Product design
| Cable dimensions | 1X70 |
|---|---|
| Nominal conductor cross-section (metric) | 70 mm² |
| Conductor material | Bare copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | No |
| Number of cores | 1 |
| Shielded | No |
| Nominal outer diameter | 17 mm |
| Cable shape | Round |
| Core insulation basic material | Halogen-free compound |
| Core insulation basic material, short form | HFFR |
| Insulation colour | red |
| Basic material of outer sheath | Halogen-free compound |
| Basic material of outer sheath, short form | HFFR |
| Outer sheath colour | black |
Product features
| Application area | Flexible; Fixed installation |
|---|---|
| For torsional load | Yes |
| Minimum bending radius, stationary | 4 x outer diameter |
| Minimum bending radius in mm, fixed installation | 68 mm |
| Minimum bending radius, occasionally flexing | 15 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 255 mm |
| Torsion | for +/- 150 °/m and min. 5 °C up to 5000 Torsion cycles; for +/- 150 °/m and min. 20 °C up to 2000 Torsion cycles |
| Temperature, fixed installation | -40 °C to 80 °C max. conductor temperature |
| Temperature, fixed installation max | 80 °C |
| Temperature, fixed installation min | -40 °C |
| max. conductor temperature, occasionally moved | -5 °C to 70 °C max. conductor temperature |
| Temperature, occasionally moved max | 70 °C |
| Temperature, occasionally moved min | -5 °C |
| Flame-retardant | Yes |
| Flame retardance according to | IEC 60332-1-2; IEC 60332-3-24 |
| Low smoke density according to | IEC 61034-2 |
| Low toxicity of combustion gases according to | EN 50306-1 (≤ 3) |
| Corrosiveness of combustion gases according to | IEC 60754-2 |
| UV-resistant | Yes |
| UV-resistant according to | EN ISO 4892-2, method A (colour change permitted); EN 50618; EN 50620; EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use) |
| Ozone-resistant | Yes |
| Ozone-resistant according to | EN 50396, method B |
| Halogen-free | Yes |
| Halogen-free according to | IEC 60754-1 |
| Oil-resistant | No |
| PWIS-free | Yes |
| PWIS-free according to | VDMA 24364-B2-L |
Certifications and standards
| CE marking | Yes |
|---|---|
| UL recognized | No |
| UL listed | No |
| cUR recognised | No |
| cUL listed | No |
| CSA certified | No |
| VDE certified | No |
| Product standard DIN / EN | based on EN 50525-3-11 |
| DNV-certified | No |
| CPR fire class | Cca |
| CPR smoke density | s1a |
| CPR drip behaviour | d2 |
| CPR acidity | a1 |
| Flame retardance tested according to UN/ECE-R118 | No |
| Fire protection tested for railway vehicles | No |
Datasheets and certificates
- Data sheet: DB1123800EN.pdf
- CE declaration of conformity: CE1123800EN.pdf
- CPR declaration of performance: UILCPRDOP20_1123800-1EN.pdf
Manufacturer notes
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.






Reviews
There are no reviews yet.