Power and control cable; 5X0.75; U0/U: 300/500 V; PUR; Core identification: Numbers; Shielded; Flexible
Benefits
- Durable, resistant product thanks to the outer sheath PUR material that is resistant to abrasions, notches and cuts.
- Additional robustness thanks to the extruded inner sheath.
- Ideal protection against electromagnetic interference thanks to copper stranded shielding with a high degree of coverage.
Applications
- For universal use for wiring machine-internal and cross-plant control circuits.
- Especially for environments where electromagnetic compatibility (EMC) is required.
- For fixed installation and occasional movement without tensile strain.
- The PUR outer sheath withstands high mechanical loads.
- The PUR outer sheath is resistant to mineral oil-based lubricants and highly resistant to chemicals.
- Suitable for outdoor use, subject to the temperature range.
Technical specifications
General information
| Brand | ÖLFLEX® |
|---|---|
| Product type | Power and control cable |
| Weight | 128 kg/km |
| Copper index | 84 kg/km |
| Industry segment | Assembly Machines; Lifts & Elevators; Processing Industries; Ships & boats |
| customs code | 85444995 |
Electrical parameters
| Nominal voltage | U0/U: 300/500 V AC rms according to IEC |
|---|---|
| Test voltage core/core | 4 kV |
| Test voltage core/screening | 4 kV |
| Current rating according to | VDE 0298-4 |
| Max. conductor resistance at 20°C | 26 Ω/km |
| Conductor/conductor operating capacitance (800Hz), approx. | 125 nF/km |
| Conductor/shielding operating capacitance (800Hz), approx. | 194 nF/km |
| Inductance (800 Hz), approx. | 0.688 mH/km |
Product design
| Cable dimensions | 5X0.75 |
|---|---|
| Nominal conductor cross-section (metric) | 0.75 mm² |
| Conductor material | Bare copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | No |
| Number of cores | 5 |
| Stranding type | Layered stranding |
| Shielded | Yes |
| Type of overall screening | Tin-plated copper braiding |
| Optical degree of coverage of the stranded screening, overall screen | 85 % |
| Nominal outer diameter | 8.9 mm |
| Cable shape | Round |
| Core insulation basic material | Polyvinylchloride |
| Core insulation basic material, short form | PVC |
| Basic material of inner sheath | Polyvinylchloride |
| base material inner sheath shortname | PVC |
| Inner sheath colour | grey |
| Basic material of outer sheath | Polyurethane |
| Basic material of outer sheath, short form | PUR |
| Outer sheath colour | grey |
| Cable sheath RAL colour | RAL 7001 |
| Core identification | Numbers |
| Conductor colour code | EN 50334; VDE 0293-1 |
Product features
| Application area | Flexible; Fixed installation |
|---|---|
| Minimum bending radius, stationary | 6 x outer diameter |
| Minimum bending radius in mm, fixed installation | 53.4 mm |
| Minimum bending radius, occasionally flexing | 20 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 178 mm |
| Temperature, fixed installation | -40 °C to 80 °C max. conductor temperature |
| Temperature, fixed installation max | 80 °C |
| Temperature, fixed installation min | -40 °C |
| max. conductor temperature, occasionally moved | -5 °C to 70 °C max. conductor temperature |
| Temperature, occasionally moved max | 70 °C |
| Temperature, occasionally moved min | -5 °C |
| Storage temperature min. | -25 °C |
| Max. storage temperature | 55 °C |
| Flame-retardant | No |
| UV-resistant | Yes |
| UV-resistant according to | EN ISO 4892-2, method A (colour change permitted); EN 50618; EN 50620 |
| Weather-resistant | Yes |
| Ozone-resistant | Yes |
| Ozone-resistant according to | EN 50396, method B |
| Chemical resistant | Yes |
| Hydrolysis-resistant | Yes |
| Halogen-free | No |
| Oil-resistant | Yes |
| Oil resistance according to | EN 50363-10-2 |
| PWIS-free | Yes |
| PWIS-free according to | VDMA 24364-B2-L |
Certifications and standards
| CE marking | Yes |
|---|---|
| EAC-certified | Yes |
| EAC certification number | ЕАЭС N RU Д-DE.АЮ64.В.00130/20 |
| UL recognized | No |
| UL listed | No |
| cUR recognised | No |
| cUL listed | No |
| CSA certified | No |
| VDE certified | No |
| HAR certified | No |
| Flame retardance tested according to UN/ECE-R118 | No |
| Ecolab certified | Yes |
Datasheets and certificates
- Data sheet: DB1313852EN.pdf
- ECOLAB certificate: EC1313852EN.pdf
- CE declaration of conformity: CE1313852EN.pdf
- CPR declaration of performance: UILCPRDOP19_1313852-1EN.pdf
Manufacturer notes
- Inductance and operating capacitance are neither defined nor controlled electrical parameters. The specified values were determined by calculation and may deviate due to tolerances.
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.






Reviews
There are no reviews yet.