Power and control cable; 12G0.75; U0/U: 300/500 V; PVC; Core identification: Numbers; Shielded; UL recognized; H05VVC4V5-K; Flexible
Benefits
- Cable with multiple certifications enables universal use and reduces the number of parts, therefore guaranteeing logistics savings.
- UL/CSA certification according to technical data enables the product to be used in the North American market.
- High oil resistance according to DIN EN 50363-4-1 (TM5).
- Tested resistance to ECOLAB® disinfectants and cleaning agents.
- Ideal protection against electromagnetic interference thanks to copper stranded shielding with a high degree of coverage.
Applications
- For universal use for wiring machine-internal and cross-plant control circuits.
- For fixed installation and occasional movement without tensile strain.
- Can be used in dry and damp conditions, and especially in oily environments.
- Suitable for medium mechanical stress.
- The PVC outer sheath is resistant to acids and alkalis.
Technical specifications
General information
| Brand | ÖLFLEX® |
|---|---|
| Product type | Power and control cable |
| Weight | 325 kg/km |
| Copper index | 155 kg/km |
| Industry segment | Agricultural & Farm Machinery; Food & Beverage; Healthcare & Pharma; Intralogistics; Packaging |
| customs code | 85444995 |
Electrical parameters
| Nominal voltage | U0/U: 300/500 V AC rms according to IEC |
|---|---|
| Rated voltage | 600 V AC rms according to UL/CSA |
| Test voltage core/core | 3 kV |
| Test voltage core/screening | 3 kV |
| Max. conductor resistance at 20°C | 26 Ω/km |
| Conductor/conductor operating capacitance (800Hz), approx. | 101 nF/km |
| Conductor/shielding operating capacitance (800Hz), approx. | 157 nF/km |
| Inductance (800 Hz), approx. | 0.763 mH/km |
Product design
| Harmonised design | H05VVC4V5-K |
|---|---|
| Cable dimensions | 12G0.75 |
| Nominal conductor cross-section (metric) | 0.75 mm² |
| Nominal conductor cross-section (AWG) | 19 AWG |
| Leading conductor cross-section | mm² |
| Conductor material | Bare copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | Yes |
| Number of cores | 12 |
| Stranding type | Layered stranding |
| Shielded | Yes |
| Type of overall screening | Tin-plated copper braiding |
| Nominal outer diameter | 14.8 mm |
| Cable shape | Round |
| Core insulation basic material | Polyvinylchloride |
| Core insulation basic material, short form | PVC |
| Basic material of inner sheath | Polyvinylchloride |
| base material inner sheath shortname | PVC |
| Inner sheath colour | grey |
| Basic material of outer sheath | Polyvinylchloride |
| Basic material of outer sheath, short form | PVC |
| Outer sheath colour | grey |
| Core identification | Numbers |
| Conductor colour code | VDE 0293-1; EN 50334 |
Product features
| Application area | Flexible; Fixed installation |
|---|---|
| For torsional load | No |
| Minimum bending radius, stationary | 6 x outer diameter |
| Minimum bending radius in mm, fixed installation | 88.8 mm |
| Minimum bending radius, occasionally flexing | 20 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 296 mm |
| Temperature, fixed installation | to 90 °C max. conductor temperature according to UL AWM; to 90 °C max. conductor temperature according to CSA AWM; -40 °C to 70 °C max. conductor temperature |
| Temperature, fixed installation max | 90 °C |
| Temperature, fixed installation min | -40 °C |
| max. conductor temperature, occasionally moved | to 90 °C max. conductor temperature according to UL AWM; -5 °C to 70 °C max. conductor temperature; to 90 °C max. conductor temperature according to CSA AWM |
| Temperature, occasionally moved max | 90 °C |
| Temperature, occasionally moved min | -5 °C |
| Storage temperature min. | 5 °C |
| Max. storage temperature | 40 °C |
| Flame-retardant | Yes |
| Flame retardance according to | IEC 60332-1-2; UL Cable Flame Test; UL VW-1; CSA FT1 |
| UV-resistant | No |
| Chemical resistant | Yes |
| Halogen-free | No |
| Oil-resistant | Yes |
| Oil resistance according to | EN 50363-4-1: TM5; UL 80°C rating according to UL 758; CSA C22.2 No. 210-15 |
| PWIS-free | Yes |
| PWIS-free according to | VDMA 24364-B2-L |
Certifications and standards
| CE marking | Yes |
|---|---|
| EAC-certified | Yes |
| EAC certification number | ЕАЭС N RU Д-DE.АЮ64.В.00130/20 |
| UL recognized | Yes |
| UL AWM certification | 21098 according to UL 758 (e-file number: E63634) |
| UL listed | No |
| cUR recognised | No |
| cUL listed | No |
| CSA certified | Yes |
| CSA certification | AWM II B according to CSA C22.2 No. 210; AWM II A according to CSA C22.2 No. 210; AWM I B according to CSA C22.2 No. 210; AWM I A according to CSA C22.2 No. 210 |
| VDE certified | No |
| HAR certified | Yes |
| Product standard DIN / EN | EN 50525-2-51 |
| CPR fire class | Dca |
| CPR smoke density | s3 |
| CPR drip behaviour | d0 |
| CPR acidity | a3 |
| Flame retardance tested according to UN/ECE-R118 | No |
| Ecolab certified | Yes |
Datasheets and certificates
- Data sheet: DB0015703EN.pdf
- UL approval: ZUE63634.pdf
- VDE approval: ZV0015703DE_EN.pdf
- ECOLAB certificate: EC0015703EN.pdf
- CE declaration of conformity: CE0015703EN.pdf
- CE declaration of conformity: CE0015703EN.pdf
- CPR declaration of performance: UILCPRDOP18_0015703-1EN.pdf
Manufacturer notes
- Inductance and operating capacitance are neither defined nor controlled electrical parameters. The specified values were determined by calculation and may deviate due to tolerances.
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.






Reviews
There are no reviews yet.