Benefits
- Cable specially developed for use in the USA.
- Versatile use in various applications and environments.
- UL certification according to technical data enables the product to be used on the North American market.
- Product with multiple certifications enables universal use and reduces the variety of parts, thus guaranteeing logistics savings.
- Particularly oil-resistant and flame retardant.
- Ideal protection against electromagnetic interference thanks to double shielding made of aluminium-laminated foil and copper stranded shielding with a high degree of coverage.
Applications
- Suitable for medium mechanical stress.
Technical specifications
General information
| Brand | ÖLFLEX® |
|---|---|
| Product type | Power and control cable |
| Weight | 189 kg/km |
| Copper index | 93.5 kg/km |
| Industry segment | Construction Machinery; Power Grids; Food & Beverage; Healthcare & Pharma; Intralogistics; Machine tools; Packaging; Processing Industries; Robotics |
| customs code | 85444995 |
Electrical parameters
| Nominal voltage | U0/U: 0,6/1 kV AC rms according to IEC |
|---|---|
| Rated voltage | 600 V AC rms according to UL TC; 600 V AC rms according to c(UL) CIC/TC; 600 V AC rms according to UL MTW; 1000 V AC rms according to UL WTTC; 1000 V AC rms according to UL AWM; 1000 V AC rms according to CSA AWM |
| Test voltage | 2 kV |
| Current rating according to | NEC / NFPA 70; NFPA 79; IEC 60364-5-52 |
| Max. conductor resistance at 20°C | 13.7 Ω/km |
Product design
| Cable dimensions | 5G1.5 |
|---|---|
| Nominal conductor cross-section (metric) | 1.5 mm² |
| Nominal conductor cross-section (AWG) | 16 AWG |
| Leading conductor cross-section | mm² |
| Conductor material | Bare copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | Yes |
| Number of cores | 5 |
| Shielded | Yes |
| Type of overall screening | Aluminium-laminated plastic foil; Tin-plated copper braiding |
| Nominal core diameter | 2.61 mm |
| Min. outer diameter | 9.66 mm |
| Nominal outer diameter | 10.3 mm |
| Max. outer diameter | 10.94 mm |
| Cable shape | Round |
| Core insulation basic material | Polyvinylchloride |
| Core insulation basic material, short form | PVC |
| Insulation skin | Nylon |
| Basic material of outer sheath | Thermoplastic |
| Outer sheath colour | black |
| Core identification | Numbers |
Product features
| Application area | Flexible; Fixed installation; Torsion |
|---|---|
| For torsional load | Yes |
| Suitable for use in accordance with NEC chapter 5 | Class I Division 2 |
| Minimum bending radius, stationary | 6 x outer diameter |
| Minimum bending radius in mm, fixed installation | 65.6 mm |
| Minimum bending radius, occasionally flexing | 6 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 65.6 mm |
| Torsion | for +/- 150 °/m and min. 5 °C up to 5000 Torsion cycles; for +/- 150 °/m and min. -40 °C up to 2000 Torsion cycles |
| Temperature, fixed installation | -40 °C to 70 °C max. conductor temperature according to IEC; -25 °C to 90 °C max. conductor temperature according to UL MTW; -40 °C to 105 °C max. conductor temperature according to CSA AWM; -25 °C to 90 °C max. conductor temperature according to UL/CSA TC; -40 °C to 105 °C max. conductor temperature according to UL AWM |
| Temperature, fixed installation max | 105 °C |
| Temperature, fixed installation min | -40 °C |
| max. conductor temperature, occasionally moved | -25 °C to 70 °C max. conductor temperature according to IEC; -25 °C to 105 °C max. conductor temperature according to CSA AWM; -25 °C to 90 °C max. conductor temperature according to UL MTW; -25 °C to 90 °C max. conductor temperature according to UL/CSA TC; -25 °C to 105 °C max. conductor temperature according to UL AWM |
| Temperature, occasionally moved max | 105 °C |
| Temperature, occasionally moved min | -25 °C |
| Storage temperature min. | -40 °C |
| Max. storage temperature | 40 °C |
| Flame-retardant | Yes |
| Flame retardance according to | UL Vertical-Tray Flame Test; CSA FT4; IEC 60332-3-24 |
| UV-resistant | Yes |
| UV-resistant according to | UL sunlight resistant; EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use) |
| Weather-resistant | Yes |
| Ozone-resistant | Yes |
| Halogen-free | No |
| Oil-resistant | Yes |
| Oil resistance according to | UL OILRES I; UL OILRES II; CSA C22.2 No. 210-15 |
Certifications and standards
| CE marking | Yes |
|---|---|
| EAC-certified | Yes |
| EAC certification number | ЕАЭС RU С-DE.АЮ64.В.00091/19 |
| UL recognized | Yes |
| UL AWM certification | 20886 according to UL 758 (e-file number: E100338) |
| UL listed | Yes |
| UL certification | UL TC-ER according to UL 1277 (e-file number: E171371); UL 90°C DRY according to UL 1277 (e-file number: E171371); UL MTW according to UL 1063 (e-file number: E155920); UL WTTC according to UL 2277 (e-file number: E323700); UL DP-1 according to UL 1690 (e-file number: E233406); UL PLTC-ER according to UL 13 (e-file number: E216027); UL ITC-ER according to UL 2250 (e-file number: E196134); UL SUN RES according to UL 1277 (e-file number: E171371); UL DIR BUR according to UL 1277 (e-file number: E171371); UL 75°C WET according to UL 1277 (e-file number: E171371) |
| cUR recognised | No |
| cUL listed | Yes |
| cUL certification | cUL CIC/TC 600V according to CSA C22.2 No. 239 (e-file number: E171371) |
| CSA certified | Yes |
| CSA certification | AWM II B according to CSA C22.2 No. 210; AWM I A according to CSA C22.2 No. 210; AWM I B according to CSA C22.2 No. 210; AWM II A according to CSA C22.2 No. 210 |
| VDE certified | No |
| HAR certified | No |
| Ecolab certified | Yes |
Datasheets and certificates
Manufacturer notes
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.





Reviews