Railway cable; 3X4; EN 50264-3-2; Type MM S; U0/U: 0,6/1 kV; -40 – 120 °C; Electron beam cross-linked polymer compound; Shielded
Benefits
- Good chemical resistance
- Copper screening complies with EMC requirements and protects against electromagnetic interference
- Resistant to mechanical influences in harsh environmental conditions
- Extended temperature range
- Reduced flame spreading increases the protection against damage to persons and property in the event of a fire
Applications
- For use in railway vehicles, for fixed installations and applications where limited movement may occur
- Suitable for connecting lamps, heating equipment, switchgear, terminal boxes and power supply
- Also applicable within oily environments and areas with increased ambient temperature
Technical specifications
General information
| Brand | ÖLFLEX® |
|---|---|
| Product type | Railway cable |
| Weight | 290 kg/km |
| Copper index | 167.66 kg/km |
| Industry segment | Power Grids; Rolling Stock |
| customs code | 85444995 |
Electrical parameters
| Nominal voltage | U0/U: 0,6/1 kV AC rms according to IEC |
|---|---|
| Maximum operating voltage Um | 1,2 kV AC |
| Test voltage core/core | 3.5 kV |
| Test voltage core/screening | 3.5 kV |
| Current rating according to | EN 50355 |
| Short-circuit temperature [5s] | 200 °C |
| Max. conductor resistance at 20°C | 5.09 Ω/km |
| Conductor/conductor operating capacitance (800Hz), approx. | 77 nF/km |
| Conductor/shielding operating capacitance (800Hz), approx. | 119 nF/km |
| Inductance (800 Hz), approx. | 0.644 mH/km |
Product design
| Cable design abbreviations for railway vehicles | Type MM S |
|---|---|
| Cable dimensions | 3X4 |
| Nominal conductor cross-section (metric) | 4 mm² |
| Conductor material | Tin-plated copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | No |
| Number of cores | 3 |
| Stranding type | Layered stranding |
| Shielded | Yes |
| Type of overall screening | Tin-plated copper braiding |
| Nominal outer diameter | 11.4 mm |
| Cable shape | Round |
| Core insulation basic material | Electron beam cross-linked polymer compound |
| Basic material of outer sheath | Electron beam cross-linked polymer compound |
| Outer sheath colour | black |
| Core identification | Numbers |
| Conductor colour code | VDE 0293-1 |
Product features
| Application area | Fixed installation |
|---|---|
| Minimum bending radius, stationary | 5 x outer diameter |
| Minimum bending radius in mm, fixed installation | 57 mm |
| Temperature, fixed installation | -40 °C to 120 °C max. conductor temperature; -50 °C according to GOST |
| Temperature, fixed installation max | 120 °C |
| Temperature, fixed installation min | -50 °C |
| Flame-retardant | Yes |
| Flame retardance according to | IEC 60332-1-2; IEC 60332-3-25; NF-C 32-070 (C1); NF-C 32-070 (C2); NF-F 16-101 (A1); NF-F 16-101 (A2); NF-F 16-101 (B); NF-F 16-101 (C) |
| Low smoke density according to | EN 50264-1; IEC 61034-2; NF X 10-702 |
| Low toxicity of combustion gases according to | EN 50264-1; EN 50305; NF X 70-100 |
| Corrosiveness of combustion gases according to | EN 50264-1; IEC 60754-2 |
| UV-resistant | Yes |
| UV-resistant according to | EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use) |
| Ozone-resistant | Yes |
| Ozone-resistant according to | EN 50264-3-1, method B; EN 50305 |
| Chemical resistant | Yes |
| Acid-resistant | Yes |
| Acid-resistant according to | EN 50264-3-1 |
| Alkali-resistant | Yes |
| Alkali-resistant according to | EN 50264-3-1 |
| Halogen-free | Yes |
| Halogen-free according to | IEC 60754-1; EN 60684-2 |
| Oil-resistant | Yes |
| Oil resistance according to | EN 50264-3-1 |
| Fuel-resistant | Yes |
| Fuel-resistant according to | EN 50264-3-1 |
Certifications and standards
| CE marking | Yes |
|---|---|
| EAC-certified | Not required |
| EAC certification number | Отказное письмо № 62, 04276 |
| VDE certified | No |
| Flame retardance tested according to UN/ECE-R118 | No |
| Fire protection tested for railway vehicles | Yes |
| Fire protection for railway vehicles hazard level | EN 45545-2 HL1; EN 45545-2 HL2; EN 45545-2 HL3 |
| Standard for railway vehicles | EN 50264-3-2 |
Datasheets and certificates
- Data sheet: DB15345000EN.pdf
- CE declaration of conformity: CE15345000EN.pdf
- Certificate HL classification TRAIN: HL15345000DE_EN.pdf
Manufacturer notes
- Inductance and operating capacitance are neither defined nor controlled electrical parameters. The specified values were determined by calculation and may deviate due to tolerances.
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.




Reviews