LAPP ÖLFLEX® FD 891 CY 5G0,5 – 1027005

Price after configuration

Anschluss- und Steuerleitung; 5G0.5; Core-Line; U0/U: 300/500 V; PVC; Aderidentifizierung: Nummern; Geschirmt; UL recognized; Schleppkette

Wählen Sie eine Lieferkonfiguration, um Preis und Verfügbarkeit zu prüfen.

Power and control cable; 5G0.5; Core-Line; U0/U: 300/500 V; PVC; Core identification: Numbers; Shielded; UL recognized; Cable chain

Choose a verified supply configuration to check price and availability.

Order options

SKU: LAPP-1027005 Category: Brand:

Delivery time: 5–7 business days

For longer lengths or custom cable lengths, please contact us.
Contact us / Request a quote ↗Product details are filled in automatically. Tell us the quantity or length you need.
Request a quote for this product

Request a quote with no obligation — no account needed.

LAPP ÖLFLEX® FD 891 CY 5G0,5 – 1027005
LAPP ÖLFLEX® FD 891 CY 5G0,5 – 1027005SKU: LAPP-1027005

We use your details to handle your enquiry. Privacy policy

Anschluss- und Steuerleitung; 5G0.5; Core-Line; U0/U: 300/500 V; PVC; Aderidentifizierung: Nummern; Geschirmt; UL recognized; Schleppkette

Vorteile

  • Hochflexibler Leitungsaufbau bedingt sehr gute Produktperformance.
  • Langlebiger Schleppketteneinsatz bei mittleren Verfahrwegen oder erhöhten Beschleunigungen (LAPP-Performanceklasse „Core Line“).
  • Kürzere Aderverseilung erlaubt sehr kleine Biegeradien.
  • Idealer Schutz vor elektromagnetischer Störung durch Kupferabschirmgeflecht mit hohem Bedeckungsgrad.
  • UL-/CSA-Zertifizierung gemäß Technischen Daten ermöglicht Verwendung des Produkts im nordamerikanischen Raum.
  • Produkt mit Mehrfach-Zertifizierung ermöglicht universellen Einsatz, reduziert Teilevielfalt und sorgt so für Einsparungen in der Logistik.
  • Klassifiziertes Brandverhalten gemäß EU-Richtlinie 305/2011 (BauPVO/CPR) mit Artikelnummer-Auswahl auf der LAPP-Website.

Anwendungsbereiche

  • Leitungsaufbau erlaubt flexiblen, dauerbewegten Einsatz in beweglichen Maschinenteilen und in der Schleppkette.
  • Für die Verwendung in Steuer-, Regelungs- und Messstromkreisen.
  • Speziell für Umgebungen, in denen elektromagnetische Verträglichkeit (EMV) gefordert ist.
  • Einsetzbar in trockenen, feuchten und nassen Umgebungen.
  • Für mittlere mechanische Beanspruchung geeignet.
  • PVC-Außenmantel ist beständig gegenüber Säuren und Laugen und bedingt ölbeständig.
  • Für den Außenbereich geeignet, unter Beachtung des Temperaturbereichs.

Produkthinweise

  • Bei Einsatz in Schleppketten: Bitte technische Montagerichtlinie T3 beachten
  • Biegezyklen und Einsatzparameter: Bitte Auswahltabelle A2-1 beachten

Technische Daten

Allgemeine Informationen
Marke ÖLFLEX®
Produkttyp Anschluss- und Steuerleitung
Gewicht 127 kg/km
Kupferzahl 55.3 kg/km
Performance-Klasse Core-Line
Industrie Segment Automotive; Prozessindustrie
Zolltarifnummer 85444995
Elektrische Kennwerte
Nennspannung U0/U: 300/500 V AC rms nach IEC
Bemessungsspannung 600 V AC rms nach CSA AWM; 600 V AC rms nach UL AWM
Prüfspannung Ader/Ader 4 kV
Prüfspannung Ader/Schirm 4 kV
Strombelastbarkeit nach VDE 0298-4
Max. Leiterwiderstand bei 20 °C 39 Ω/km
Betriebskapazität Ader/Ader (800Hz), ca. 106 nF/km
Betriebskapazität Ader/Schirm (800Hz), ca 164 nF/km
Induktivität (800Hz), ca. 0,753 mH/km
Produktaufbau
Leitungsabmessung 5G0.5
Leiternennquerschnitt (metrisch) 0,5 mm²
Leiternennquerschnitt (AWG) 21 AWG
Führender Leiterquerschnitt mm²
Leitermaterial blankes Kupfer
Leiteraufbau IEC 60228 Klasse 6: feinstdrähtig
Einschließlich Schutzleiter Ja
Anzahl Adern 5
Verseilart Lagenverseilung
Bewicklung über Verseilung Vliesbewicklung
Geschirmt Ja
Art des Gesamtschirm verzinntes Kupfergeflecht
Nennaussendurchmesser 9,2 mm
Leitungsform rund
Grundmaterial der Aderisolation Polyvinylchlorid
Grundmaterial der Aderisolation, Kurzform PVC
Grundmaterial des Außenmantels Polyvinylchlorid
Grundmaterial des Außenmantels, Kurzform PVC
Außenmantelfarbe schwarz
Außenmantelfarbe RAL Ton RAL 9005
Aderidentifizierung Nummern
Ader Farbcode EN 50334; VDE 0293-1
Produkteigenschaften
Einsatzgebiet Schleppkette; flexibel
Für Dauerbiegung Ja
Für Torsionsbelastung Nein
Minimaler Biegeradius, festverlegt 4 x Außendurchmesser
Minimaler Biegeradius in mm, festverlegt 36,8 mm
Minimaler Biegeradius, dynamisch dauerbewegt 7,5 x Außendurchmesser
Minimaler Biegeradius in mm, dynamisch dauerbewegt 69 mm
Minimaler Biegeradius, gelegentlich bewegt 7,5 x Außendurchmesser
Minimaler Biegeradius in mm, gelegentlich bewegt 69 mm
Maximale Biegezyklen 7.000.000
Maximaler Verfahrweg 20 m
Maximale Geschwindigkeit gleitend 5 m/s
Maximale Geschwindigkeit freitragend 10 m/s
Maximale Beschleunigung 20 m/s²
Temperatur, fest verlegt bis 90 °C max. Leitertemperatur nach UL AWM; -40 °C bis 80 °C max. Leitertemperatur nach IEC; bis 90 °C max. Leitertemperatur nach CSA AWM
Temperatur, fest verlegt max 90 °C
Temperatur, fest verlegt min -40 °C
Temperatur, gelegentlich bewegt -5 °C bis 90 °C max. Leitertemperatur nach CSA AWM; -5 °C bis 70 °C max. Leitertemperatur nach IEC; -5 °C bis 90 °C max. Leitertemperatur nach UL AWM
Temperatur, gelegentlich bewegt max 90 °C
Temperatur, gelegentlich bewegt min -5 °C
Temperatur, dynamisch dauerbewegt -5 °C bis 90 °C max. Leitertemperatur nach UL AWM; -5 °C bis 90 °C max. Leitertemperatur nach CSA AWM; -5 °C bis 70 °C max. Leitertemperatur nach IEC
Temperatur, dynamisch dauerbewegt max 90 °C
Temperatur, dynamisch dauerbewegt min -5 °C
Flammwidrig Ja
Flammwidrigkeit nach IEC 60332-1-2; UL VW-1; CSA FT1
UV-beständig Ja
UV-beständig nach EN ISO 4892-2, Methode A (Farbänderung zulässig); EN 50525-1 (Leitungen mit schwarzem Mantel sind für dauerhaften Einsatz im Freien geeignet)
Halogenfrei Nein
Ölbeständig Ja
Ölbeständigkeit nach EN 50363-4-1: TM5; UL 80°C rating nach UL 758; CSA C22.2 No.210-15
LABS-frei Ja
LABS-frei nach VDMA 24364-B2-L
Adhäsionsarme Manteloberfläche Ja
Zertifizierungen und Normen
CE gekennzeichnet Ja
EAC zertifiziert Ja
EAC Zertifizierungsnummer ЕАЭС N RU Д-DE.АЮ64.В.00130/20
UL recognized Ja
UL AWM Zertifizierung 21098 nach UL 758 (e-file number: E63634); 10012 nach UL 758 (e-file number: E63634)
UL listed Nein
cUR recognized Ja
cUR Zertifizierung AWM I B nach CSA C22.2 No. 210 (e-file number: E63634); AWM I A nach CSA C22.2 No. 210 (e-file number: E63634); AWM II A nach CSA C22.2 No. 210 (e-file number: E63634); AWM II B nach CSA C22.2 No. 210 (e-file number: E63634)
cUL listed Nein
CSA zertifiziert Nein
Flammwidrigkeit nach UN/ECE-R118 getestet Nein

Datenblätter und Zertifikate

Herstellerhinweise
  • Induktivität und Betriebskapazität sind weder definierte noch kontrollierte elektrische Parameter. Die angegebenen Werte wurden durch Berechnung ermittelt und können aufgrund von Toleranzen abweichen.
  • Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie – soweit verfügbar und zur Veröffentlichung freigegeben- auf Anfrage.
  • Die Fotografien und Grafiken sind nicht maßstäblich und keine detailgetreuen Abbildungen der jeweiligen Produkte.
  • Die Abwesenheit von LABS-Rohstoffen schützt nicht vor dem potenziellen Risiko einer Kontamination mit lackbenetzungsstörenden Substanzen bei der späteren Handhabung des Produkts/der Produkte während des Transports, der Lagerung oder der Weiterverarbeitung nach der Lieferung.

LAPP Produktinformationen und Unterlagen

Hersteller-Nennwerte; Abbildungen sind repräsentativ. Maßgeblich für die Bestellung sind die bestätigte Ausführung, Menge und der angezeigte Gesamtpreis.

Power and control cable; 5G0.5; Core-Line; U0/U: 300/500 V; PVC; Core identification: Numbers; Shielded; UL recognized; Cable chain

Benefits

  • Highly flexible cable design means excellent product performance.
  • Durable cable chain use with medium travel distances or increased acceleration (LAPP „Core Line“ performance class).
  • Shorter core stranding allows very small bending radii.
  • Ideal protection against electromagnetic interference thanks to copper stranded shielding with a high degree of coverage.
  • UL/CSA certification according to technical data enables the product to be used in the North American market.
  • Product with multiple certifications enables universal use and reduces the variety of parts, thus guaranteeing logistics savings.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.

Applications

  • The cable design allows flexible, continuously moving use in moving machine parts and in cable chains.
  • For use in control, regulation and measurement circuits.
  • Especially for environments where electromagnetic compatibility (EMC) is required.
  • Can be used in dry, damp and wet environments.
  • Suitable for medium mechanical stress.
  • The PVC outer sheath is resistant to acids and alkalis and has limited oil resistance.
  • Suitable for outdoor use, subject to the temperature range.

Product notes

  • For use in cable chains: please follow the T3 technical assembly guidelines
  • Bending cycles and application parameters: please refer to the A2-1 selection table

Technical specifications

General information
Brand ÖLFLEX®
Product type Power and control cable
Weight 127 kg/km
Copper index 55.3 kg/km
Performance class Core-Line
Industry segment Automotive; Processing Industries
customs code 85444995
Electrical parameters
Nominal voltage U0/U: 300/500 V AC rms according to IEC
Rated voltage 600 V AC rms according to CSA AWM; 600 V AC rms according to UL AWM
Test voltage core/core 4 kV
Test voltage core/screening 4 kV
Current rating according to VDE 0298-4
Max. conductor resistance at 20°C 39 Ω/km
Conductor/conductor operating capacitance (800Hz), approx. 106 nF/km
Conductor/shielding operating capacitance (800Hz), approx. 164 nF/km
Inductance (800 Hz), approx. 0.753 mH/km
Product design
Cable dimensions 5G0.5
Nominal conductor cross-section (metric) 0.5 mm²
Nominal conductor cross-section (AWG) 21 AWG
Leading conductor cross-section mm²
Conductor material Bare copper
Conductor design IEC 60228 class 6: extra-fine wire
Including protective earth Yes
Number of cores 5
Stranding type Layered stranding
Wrapping over stranding Fleece wrapping
Shielded Yes
Type of overall screening Tin-plated copper braiding
Nominal outer diameter 9.2 mm
Cable shape Round
Core insulation basic material Polyvinylchloride
Core insulation basic material, short form PVC
Basic material of outer sheath Polyvinylchloride
Basic material of outer sheath, short form PVC
Outer sheath colour black
Cable sheath RAL colour RAL 9005
Core identification Numbers
Conductor colour code EN 50334; VDE 0293-1
Product features
Application area Cable chain; Flexible
For permanent bending Yes
For torsional load No
Minimum bending radius, stationary 4 x outer diameter
Minimum bending radius in mm, fixed installation 36.8 mm
Minimum bending radius, dynamic continuously flexing 7.5 x outer diameter
Minimum bending radius in mm, dynamic continuously flexing 69 mm
Minimum bending radius, occasionally flexing 7.5 x outer diameter
Minimum bending radius in mm, occasionally flexing 69 mm
Maximum bending cycles 7,000,000
Maximum travel distance 20 m
Maximum speed sliding 5 m/s
Maximum self-supporting speed 10 m/s
Maximum acceleration 20 m/s²
Temperature, fixed installation to 90 °C max. conductor temperature according to UL AWM; -40 °C to 80 °C max. conductor temperature according to IEC; to 90 °C max. conductor temperature according to CSA AWM
Temperature, fixed installation max 90 °C
Temperature, fixed installation min -40 °C
max. conductor temperature, occasionally moved -5 °C to 90 °C max. conductor temperature according to CSA AWM; -5 °C to 70 °C max. conductor temperature according to IEC; -5 °C to 90 °C max. conductor temperature according to UL AWM
Temperature, occasionally moved max 90 °C
Temperature, occasionally moved min -5 °C
Temperature, dynamic continuously flexing -5 °C to 90 °C max. conductor temperature according to UL AWM; -5 °C to 90 °C max. conductor temperature according to CSA AWM; -5 °C to 70 °C max. conductor temperature according to IEC
Temperature, dynamic continuously flexing max 90 °C
Temperature, dynamic continuously flexing min -5 °C
Flame-retardant Yes
Flame retardance according to IEC 60332-1-2; UL VW-1; CSA FT1
UV-resistant Yes
UV-resistant according to EN ISO 4892-2, method A (colour change permitted); EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)
Halogen-free No
Oil-resistant Yes
Oil resistance according to EN 50363-4-1: TM5; UL 80°C rating according to UL 758; CSA C22.2 No. 210-15
PWIS-free Yes
PWIS-free according to VDMA 24364-B2-L
Low-adhesive sheath surface Yes
Certifications and standards
CE marking Yes
EAC-certified Yes
EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20
UL recognized Yes
UL AWM certification 21098 according to UL 758 (e-file number: E63634); 10012 according to UL 758 (e-file number: E63634)
UL listed No
cUR recognised Yes
cUR certification AWM I B according to CSA C22.2 No. 210 (e-file number: E63634); AWM I A according to CSA C22.2 No. 210 (e-file number: E63634); AWM II A according to CSA C22.2 No. 210 (e-file number: E63634); AWM II B according to CSA C22.2 No. 210 (e-file number: E63634)
cUL listed No
CSA certified No
Flame retardance tested according to UN/ECE-R118 No

Datasheets and certificates

Manufacturer notes
  • Inductance and operating capacitance are neither defined nor controlled electrical parameters. The specified values were determined by calculation and may deviate due to tolerances.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.

LAPP product information and documents

Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.

Cross-section

0,5 mm²

Aderzahl

5

Colour

schwarz

Shielding

Ja