LAPP ÖLFLEX® SERVO 3D 7DSL 4G0,5+(2x0,25)+(2x2 – 1023351

LAPPArticle no. 1023351

Servoleitung; 4G0,5+(2×0,25)+(2×26 AWG); U0/U: 0,6/1 kV; PUR; Geschirmt; UL recognized; Torsion

Wählen Sie eine Lieferkonfiguration, um Preis und Verfügbarkeit zu prüfen.

Servo cable; 4G0,5+(2×0,25)+(2×26 AWG); U0/U: 0,6/1 kV; PUR; Shielded; UL recognized; Torsion

Choose a verified supply configuration to check price and availability.

Length and quantity

LAPP 33,20 €−5%
31,54 €31,54 € / m
incl. VAT · plus shipping

Availability on request.

Request a quote

SKU: LAPP-1023351 Category: Brand:

Delivery time: 5–7 business days

Request a quote →

Delivery time and availability will be confirmed in your quote.

For longer lengths or custom cable lengths, please contact us.
Contact us / Request a quote ↗Product details are filled in automatically. Tell us the quantity or length you need.
Request a quote for this product

Request a quote with no obligation — no account needed.

LAPP ÖLFLEX® SERVO 3D 7DSL 4G0,5+(2x0,25)+(2x2 – 1023351
LAPP ÖLFLEX® SERVO 3D 7DSL 4G0,5+(2x0,25)+(2x2 – 1023351SKU: LAPP-1023351

We use your details to handle your enquiry. Privacy policy

Servoleitung; 4G0,5+(2×0,25)+(2×26 AWG); U0/U: 0,6/1 kV; PUR; Geschirmt; UL recognized; Torsion

Vorteile

  • Platz- und gewichtsparende Hybridleitung für gleichzeitige Energieversorgung, Signal- und Datenübertragung (Einkabeltechnologie).
  • Betriebsspannung von 1000 V nach UL für Nordamerika zulässig.
  • Kompatibel zu Einkabeltechnologie-Schnittstellen wie bspw. HIPERFACE DSL® und SCS open link.
  • Spezielle Aderverseilung erlaubt zeitgleiches Biegen und Tordieren (Torsionswinkel bis ± 180°/m).
  • Erlaubt platzsparende Verlegung ohne zusätzliche Geberleitung zur Übertragung von Feedbacksignalen.
  • Geringere Anschlusskosten, bedingt durch weniger Verkabelungsaufwand und schnelle Installation weniger Komponenten.
  • Kapazitätsarme Aderisolation für lange Übertragungswege.
  • Idealer Schutz vor elektromagnetischer Störung durch Umlegung aus verzinnten Kupferdrähten, abgestimmt auf Torsionsbelastungen.
  • Bewährte Leitung, erfolgreich getestet auf 5 Mio. Torsionszyklen.
  • UL-/CSA-Zertifizierung gemäß Technischen Daten ermöglicht Verwendung des Produkts im nordamerikanischen Raum.

Anwendungsbereiche

  • Zur Verbindung von Frequenzumrichter und Servomotor.
  • Leitungsaufbau erlaubt flexiblen, dauerbewegten Einsatz mit Torsionsbeanspruchung in Industrierobotern und Handhabungsgeräten.
  • Speziell für Umgebungen, in denen elektromagnetische Verträglichkeit (EMV) gefordert ist.
  • Einsetzbar in trockenen, nassen und speziell in rauen und öligen Umgebungen.
  • PUR-Außenmantel hält hohen mechanischen Belastungen stand.
  • PUR-Außenmantel ist unempfindlich gegenüber mineralölbasierten Schmiermitteln und vielfach chemisch beständig.
  • Für den Außenbereich geeignet.
  • Flexibler Einsatz bei bis zu ‑40 °C möglich.

Produkthinweise

  • Bei Einsatz in Schleppketten: Bitte technische Montagerichtlinie T3 beachten
  • HIPERFACE DSL® ist ein eingetragenes Markenzeichen der Sick AG und dient nur zu Informations- bzw. Vergleichszwecken.

Technische Daten

Allgemeine Informationen
Marke ÖLFLEX®
Produkttyp Servoleitung
Gewicht 130 kg/km
Kupferzahl 70 kg/km
Zolltarifnummer 85444995
Elektrische Kennwerte
Nennspannung Leistungsadern U0/U: 0,6/1 kV AC rms nach IEC
Nennspannung Steueradern U0/U: 0,6/1 kV AC rms nach IEC
Nennspannung Signalpaar U0/U: 300/300 V AC rms nach IEC
Nennspannung U0/U: 0,6/1 kV AC rms nach IEC
Bemessungsspannung 1000 V AC rms nach UL AWM; 1000 V AC rms nach cRU AWM; 600 V AC rms / DC nach UL AWM; 600 V AC rms / DC nach cRU AWM
Prüfspannung Ader/Ader 4 kV
Prüfspannung Ader/Schirm 2 kV
Prüfspannung Leistungsadern 4 kV
Prüfspannung Steueradern 4 kV
Strombelastbarkeit nach VDE 0298-4; VDE 0891-1
Nennwellenwiderstand 110 Ω
Maximale Übertragungslänge 100 m
Produktaufbau
Leiter Anzahl/Größe 4G0,5+(2×0,25)+(2×26 AWG)
Kompatibles Antriebs-/Feedbacksystem SICK / HIPERFACE DSL®
Leiternennquerschnitt (metrisch) 0,5 mm²
Leiternennquerschnitt (AWG) 21 AWG
Führender Leiterquerschnitt mm²
Leitermaterial blankes Kupfer
Leiteraufbau IEC 60228 Klasse 6: feinstdrähtig
Einschließlich Schutzleiter Ja
Anzahl Adern 4
Anzahl Paare 2
Art der Paarschirmung alukaschierte Kunststofffolie; alubedampftes Vlies; verzinntes Kupfergeflecht
Leitungselement 1 Leistungsader: 4G0.5
Leitungselement 2 Steuerpaar: 1x(2×0.25), Schirm: verzinntes Kupfergeflecht
Leitungselement 3 Signalpaar: 1x(2×26 AWG), Schirm: verzinntes Kupfergeflecht und alubedampftes Vlies
Verseilart Lagenverseilung
Bewicklung über Verseilung PTFE-Folie
Geschirmt Ja
Art des Gesamtschirm Umlegung aus verzinnten Kupferdrähten
Nennaussendurchmesser 9,4 mm
Leitungsform rund
Grundmaterial der Aderisolation Polypropylen
Grundmaterial der Aderisolation, Kurzform PP
Grundmaterial des Außenmantels Polyurethan
Grundmaterial des Außenmantels, Kurzform PUR
Außenmantelfarbe schwarz
Außenmantelfarbe RAL Ton RAL 9005
Aderidentifizierung Alphanumerisch und Farben
Produkteigenschaften
Einsatzgebiet Torsion; Schleppkette; flexibel
Für Dauerbiegung Ja
Minimaler Biegeradius, festverlegt 5 x Außendurchmesser
Minimaler Biegeradius in mm, festverlegt 47 mm
Minimaler Biegeradius, dynamisch dauerbewegt 10 x Außendurchmesser
Minimaler Biegeradius in mm, dynamisch dauerbewegt 94 mm
Minimaler Biegeradius, gelegentlich bewegt 10 x Außendurchmesser
Minimaler Biegeradius in mm, gelegentlich bewegt 94 mm
Maximale Biegezyklen 5.000.000
Maximaler Verfahrweg 20 m
Maximale Geschwindigkeit gleitend 5 m/s
Maximale Geschwindigkeit freitragend 10 m/s
Maximale Beschleunigung 30 m/s²
Torsion Bei +/- 180 °/m und min. -40 °C bis zu 5000000 Torsionszyklen
Temperatur, fest verlegt -50 °C bis 80 °C max. Leitertemperatur nach IEC; bis 80 °C max. Leitertemperatur nach UL AWM; bis 80 °C max. Leitertemperatur nach CSA AWM
Temperatur, fest verlegt max 80 °C
Temperatur, fest verlegt min -50 °C
Temperatur, gelegentlich bewegt -40 °C bis 80 °C max. Leitertemperatur nach IEC; bis 80 °C max. Leitertemperatur nach UL AWM; bis 80 °C max. Leitertemperatur nach CSA AWM
Temperatur, gelegentlich bewegt max 80 °C
Temperatur, gelegentlich bewegt min -40 °C
Temperatur, dynamisch dauerbewegt -40 °C bis 80 °C max. Leitertemperatur nach IEC; bis 80 °C max. Leitertemperatur nach UL AWM; bis 80 °C max. Leitertemperatur nach CSA AWM
Temperatur, dynamisch dauerbewegt max 80 °C
Temperatur, dynamisch dauerbewegt min -40 °C
Flammwidrig Ja
Flammwidrigkeit nach IEC 60332-1-2; UL VW-1; CSA FT1
UV-beständig Ja
UV-beständig nach EN 50525-1 (Leitungen mit schwarzem Mantel sind für dauerhaften Einsatz im Freien geeignet)
Witterungsbeständig Ja
Ozonbeständig Ja
Ozonbeständig nach EN 50396, Methode B
Chemisch beständig Ja
Hydrolysebeständig Ja
Halogenfrei Nein
Ölbeständig Ja
Ölbeständigkeit nach EN 50363-10-2
LABS-frei Nein
Kapazitätsarm Ja
Adhäsionsarme Manteloberfläche Ja
Zertifizierungen und Normen
CE gekennzeichnet Ja
UL recognized Ja
UL AWM Zertifizierung 21223 nach UL 758 (e-file number: E63634); 10867 nach UL 758 (e-file number: E63634); 1887 nach UL 758 (e-file number: E63634)
UL listed Nein
cUR recognized Ja
cUR Zertifizierung AWM I A nach CSA C22.2 No. 210 (e-file number: E63634); AWM I B nach CSA C22.2 No. 210 (e-file number: E63634); AWM II A nach CSA C22.2 No. 210 (e-file number: E63634); AWM II B nach CSA C22.2 No. 210 (e-file number: E63634)
cUL listed Nein
CSA zertifiziert Nein
VDE zertifiziert Nein

Datenblätter und Zertifikate

Herstellerhinweise
  • Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie – soweit verfügbar und zur Veröffentlichung freigegeben- auf Anfrage.
  • Die Fotografien und Grafiken sind nicht maßstäblich und keine detailgetreuen Abbildungen der jeweiligen Produkte.
  • HIPERFACE DSL® ist ein registriertes Warenzeichen der SICK AG, ACURO®link und SCS open link sind registrierte Warenzeichen der Hengstler GmbH.

LAPP Produktinformationen und Unterlagen

Hersteller-Nennwerte; Abbildungen sind repräsentativ. Maßgeblich für die Bestellung sind die bestätigte Ausführung, Menge und der angezeigte Gesamtpreis.

Servo cable; 4G0,5+(2×0,25)+(2×26 AWG); U0/U: 0,6/1 kV; PUR; Shielded; UL recognized; Torsion

Benefits

  • Space-saving and weight-saving hybrid cable for simultaneous power supply, signal and data transmission (one-cable technology).
  • Operating voltage of 1000 V according to UL, permitted for North America.
  • Compatible with single-cable technology interfaces such as HIPERFACE DSL® and SCS open link.
  • Special core stranding allows simultaneous bending and twisting (torsion angle up to ± 180°/m).
  • Allows space-saving installation without additional encoder cable for the transmission of feedback signals.
  • Reduced connection costs due to less cabling work and quick installation of fewer components.
  • Low-capacitance core insulation for long transmission paths.
  • Ideal protection against electromagnetic interference due to wrapping made of tin-plated copper wires, adapted to torsional loads.
  • Tried-and-tested cable, successfully tested for 5 million torsion cycles.
  • UL/CSA certification according to technical data enables the product to be used in the North American market.

Applications

  • For connecting frequency converters and servo motors.
  • The cable design allows flexible, continuously moving use under torsional stress in industrial robots and handling devices.
  • Especially for environments where electromagnetic compatibility (EMC) is required.
  • Can be used in dry and wet conditions, and especially in harsh and oily environments.
  • The PUR outer sheath withstands high mechanical loads.
  • The PUR outer sheath is resistant to mineral oil-based lubricants and highly resistant to chemicals.
  • Suitable for outdoor use.
  • Flexible use at temperatures down to -40°C.

Product notes

  • For use in cable chains: please follow the T3 technical assembly guidelines
  • HIPERFACE DSL® is a registered trademark of Sick AG and is used for information and comparison purposes only.

Technical specifications

General information
Brand ÖLFLEX®
Product type Servo cable
Weight 130 kg/km
Copper index 70 kg/km
customs code 85444995
Electrical parameters
Power cores nominal voltage U0/U: 0,6/1 kV AC rms according to IEC
Nominal voltage control cores U0/U: 0,6/1 kV AC rms according to IEC
Signal pair nominal voltage U0/U: 300/300 V AC rms according to IEC
Nominal voltage U0/U: 0,6/1 kV AC rms according to IEC
Rated voltage 1000 V AC rms according to UL AWM; 1000 V AC rms according to cRU AWM; 600 V AC rms / DC according to UL AWM; 600 V AC rms / DC according to cRU AWM
Test voltage core/core 4 kV
Test voltage core/screening 2 kV
Power cores test voltage 4 kV
Test voltage control cores 4 kV
Current rating according to VDE 0298-4; VDE 0891-1
Nominal surge impedance 110 Ω
Maximum transmission length 100 m
Product design
Conductor number/size 4G0,5+(2×0,25)+(2×26 AWG)
Compatible drive/feedback system SICK / HIPERFACE DSL®
Nominal conductor cross-section (metric) 0.5 mm²
Nominal conductor cross-section (AWG) 21 AWG
Leading conductor cross-section mm²
Conductor material Bare copper
Conductor design IEC 60228 class 6: extra-fine wire
Including protective earth Yes
Number of cores 4
Number of pairs 2
Pair shielding type Aluminium-laminated plastic foil; Aluminium-steamed fleece; Tin-plated copper braiding
Cable element 1 Power core: 4G0.5
Cable element 2 Control core pair: 1x(2×0.25), Shielding: Tin-plated copper braiding
Cable element 3 Signal pair: 1x(2×26 AWG), Shielding: Tin-plated copper braiding and Aluminium-steamed fleece
Stranding type Layered stranding
Wrapping over stranding PTFE film
Shielded Yes
Type of overall screening Wrapped with braided tin-plated copper wires
Nominal outer diameter 9.4 mm
Cable shape Round
Core insulation basic material Polypropylene
Core insulation basic material, short form PP
Basic material of outer sheath Polyurethane
Basic material of outer sheath, short form PUR
Outer sheath colour black
Cable sheath RAL colour RAL 9005
Core identification Alphanumeric and colours
Product features
Application area Torsion; Cable chain; Flexible
For permanent bending Yes
Minimum bending radius, stationary 5 x outer diameter
Minimum bending radius in mm, fixed installation 47 mm
Minimum bending radius, dynamic continuously flexing 10 x outer diameter
Minimum bending radius in mm, dynamic continuously flexing 94 mm
Minimum bending radius, occasionally flexing 10 x outer diameter
Minimum bending radius in mm, occasionally flexing 94 mm
Maximum bending cycles 5,000,000
Maximum travel distance 20 m
Maximum speed sliding 5 m/s
Maximum self-supporting speed 10 m/s
Maximum acceleration 30 m/s²
Torsion for +/- 180 °/m and min. -40 °C up to 5000000 Torsion cycles
Temperature, fixed installation -50 °C to 80 °C max. conductor temperature according to IEC; to 80 °C max. conductor temperature according to UL AWM; to 80 °C max. conductor temperature according to CSA AWM
Temperature, fixed installation max 80 °C
Temperature, fixed installation min -50 °C
max. conductor temperature, occasionally moved -40 °C to 80 °C max. conductor temperature according to IEC; to 80 °C max. conductor temperature according to UL AWM; to 80 °C max. conductor temperature according to CSA AWM
Temperature, occasionally moved max 80 °C
Temperature, occasionally moved min -40 °C
Temperature, dynamic continuously flexing -40 °C to 80 °C max. conductor temperature according to IEC; to 80 °C max. conductor temperature according to UL AWM; to 80 °C max. conductor temperature according to CSA AWM
Temperature, dynamic continuously flexing max 80 °C
Temperature, dynamic continuously flexing min -40 °C
Flame-retardant Yes
Flame retardance according to IEC 60332-1-2; UL VW-1; CSA FT1
UV-resistant Yes
UV-resistant according to EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)
Weather-resistant Yes
Ozone-resistant Yes
Ozone-resistant according to EN 50396, method B
Chemical resistant Yes
Hydrolysis-resistant Yes
Halogen-free No
Oil-resistant Yes
Oil resistance according to EN 50363-10-2
PWIS-free No
Low capacitance Yes
Low-adhesive sheath surface Yes
Certifications and standards
CE marking Yes
UL recognized Yes
UL AWM certification 21223 according to UL 758 (e-file number: E63634); 10867 according to UL 758 (e-file number: E63634); 1887 according to UL 758 (e-file number: E63634)
UL listed No
cUR recognised Yes
cUR certification AWM I A according to CSA C22.2 No. 210 (e-file number: E63634); AWM I B according to CSA C22.2 No. 210 (e-file number: E63634); AWM II A according to CSA C22.2 No. 210 (e-file number: E63634); AWM II B according to CSA C22.2 No. 210 (e-file number: E63634)
cUL listed No
CSA certified No
VDE certified No

Datasheets and certificates

Manufacturer notes
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • HIPERFACE DSL® is a registered trademark of SICK AG; ACURO®link and SCS open link are registered trademarks of Hengstler GmbH.

LAPP product information and documents

Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.

Cross-section

0,5 mm²

Aderzahl

4

Colour

schwarz

Shielding

Ja

Reviews

There are no reviews yet.

You must purchase this product before you can write a review. Sign in with the account you used to place your order.

Shopping Cart
Scroll to Top
WhatsApp