Benefits
- Shielded modul for data and signal transmission.
- Modular connector system, plugable with the market standard
- Crimp connection for permanent vibration proof contacting
- Railway applications – Fire protection on railway vehicles: Test according EN 45545-2. Requirement sets R22 and R23. Hazard level HL1, HL2 and HL3
- The mix of different functions in one plug guarantees high flexibility
Applications
- Mechanical engineering
- Robotics industry
- Plant engineering
- Renewable energy
- Railway applications / vehicle construction
Technical specifications
General information
| Brand | EPIC® |
|---|---|
| Product type | MH module modular system |
| Scope of delivery | Order contacts separately |
| Contacts included | No |
| Weight | 0.028 kg |
| Delivery Unit | 10 |
| Installation type | clip on |
| Industry segment | Rolling Stock |
| customs code | 85366990 |
Electrical parameters
| Rated impulse voltage | 0.8 kV AC rms / DC according to DIN EN 61984 |
|---|---|
| Rated voltage | 50 V AC rms / DC according to IEC |
| Rated current | 10 A according to IEC |
| Max. contact resistance | 4 mΩ |
| Protective earth integrated into insert | No |
Product design
| Number of contacts | 1 |
|---|---|
| Number of power contacts | 0 |
| Number of PE contacts | 0 |
| Number of signal contacts | 1 |
| Number of data contacts | 0 |
| Required slots | 2 |
| Contact insert type | Socket |
| With wire protection | No |
| With protective earth | No |
| Shield contact | Yes |
| EMC shielding | Yes |
| Conductor connection type | Crimp termination |
| Screen contact type | Terminal connection |
| Min. connectable conductor cross-section AWG | 26 AWG |
| Max. connectable conductor cross-section AWG | 14 AWG |
| Min. connectable conductor cross-section (mm2) | 0.14 mm² |
| Max. connectable conductor cross-section (mm2) | 2.5 mm² |
| Insert material | Polycarbonate |
| Insert material, short form | PC |
| Material | Brass |
| Colour | silver grey |
Product features
| Min. number of insertion cycles | 500 |
|---|---|
| Pollution degree | 3 |
| Operating temperature min. | -40 °C |
| Operating temperature max. | 100 °C |
| Flame-retardant | Yes |
| Flame retardance according to | UL 94 V-0 |
| Halogen-free | No |
Certifications and standards
| CE marking | No |
|---|---|
| UR recognised | Yes |
| UR certification | according to UL 1977 (CCN: ECBT2 / e-file number: E75770) |
| UL category control number | ECBT2 |
| cUR recognised | Yes |
| cUR certification | according to CSA C22.2 No. 182.3 (CCN: ECBT8 / e-file number: E75770) |
| cUR category control number | ECBT8 |
| CSA certified | Yes |
| VDE certified | No |
| TÜV certified | No |
| Fire protection tested for railway vehicles | Yes |
| Fire protection for railway vehicles hazard level | EN 45545-2 HL1; EN 45545-2 HL2; EN 45545-2 HL3 |
Datasheets and certificates
Manufacturer notes
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.







Reviews