Low-frequency data cable; 2X0.14; Conductor colour code: DIN 47100; PUR; Shielded; UL recognized; Cable chain
Benefits
- The combination of the very robust cable design and the wide temperature range in which it can be used provides a wide range of applications..
- Durable, resistant product thanks to the outer sheath PUR material that is resistant to abrasions, notches and cuts.
- Low-capacitance core insulation for long transmission paths or higher data transmission rates.
- Ideal protection against electromagnetic interference thanks to copper stranded shielding with a high degree of coverage.
- Relatively small bending radii thanks to highly flexible cable design.
- UL certification according to technical data enables the product to be used on the North American market.
Applications
- Can be used universally at machine interfaces for many applications for data and signal transmission in the low-frequency range.
- Especially for environments where electromagnetic compatibility (EMC) is required.
- Cable design enables flexible, continuously moving use in industrial robots (without torsional stress) and handling devices.
- The cable design allows flexible, continuously moving use in moving machine parts and in cable chains.
- Cable design also suitable for torsion applications in wind turbines.
- Can be used in dry and damp conditions, and especially in harsh and oily environments.
- The PUR outer sheath is resistant to mineral oil-based lubricants and highly resistant to chemicals.
- Suitable for outdoor use in Europe.
- Flexible use at temperatures down to -40°C.
Technical specifications
General information
| Brand | UNITRONIC® |
|---|---|
| Product type | Low-frequency data cable |
| Weight | 33 kg/km |
| Copper index | 11.2 kg/km |
| Industry segment | Assembly Machines; Construction Machinery; Healthcare & Pharma; Intralogistics; Lifts & Elevators; Machine tools; Packaging; Robotics; Ships & boats |
| customs code | 85444995 |
Electrical parameters
| Maximum operating voltage (not for power transmission) | 500 V |
|---|---|
| Test voltage core/core | 1.5 kV |
| Test voltage core/screening | 1.5 kV |
| Max. conductor resistance at 20°C | 138 Ω/km |
| Conductor/conductor operating capacitance (800Hz), approx. | 69 nF/km |
| Conductor/shielding operating capacitance (800Hz), approx. | 107 nF/km |
| Inductance (800 Hz), approx. | 0.755 mH/km |
Product design
| Cable dimensions | 2X0.14 |
|---|---|
| Nominal conductor cross-section (metric) | 0.14 mm² |
| Nominal conductor cross-section (AWG) | 26 AWG |
| Conductor material | Bare copper |
| Conductor design | extra-fine wire |
| Including protective earth | No |
| Number of cores | 2 |
| Stranding type | Layered stranding |
| Shielded | Yes |
| Type of overall screening | Tin-plated copper braiding |
| Nominal outer diameter | 4.3 mm |
| Cable shape | Round |
| Core insulation basic material | Polyolefin |
| Core insulation basic material, short form | PO |
| Basic material of outer sheath | Polyurethane |
| Basic material of outer sheath, short form | PUR |
| Outer sheath colour | grey |
| Core identification | Colours |
| Conductor colour code | DIN 47100 |
Product features
| Application area | Cable chain; Flexible |
|---|---|
| For permanent bending | Yes |
| For torsional load | No |
| Minimum bending radius, stationary | 4 x outer diameter |
| Minimum bending radius in mm, fixed installation | 17.2 mm |
| Minimum bending radius, dynamic continuously flexing | 7.5 x outer diameter |
| Minimum bending radius in mm, dynamic continuously flexing | 32.3 mm |
| Minimum bending radius, occasionally flexing | 7.5 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 32.3 mm |
| Maximum bending cycles | 5,000,000 |
| Maximum travel distance | 5 m |
| Maximum self-supporting speed | 3 m/s |
| Maximum acceleration | 3 m/s² |
| Temperature, fixed installation | -40 °C to +80 °C max. conductor temperature according to UL AWM |
| Temperature, fixed installation max | 80 °C |
| Temperature, fixed installation min | -40 °C |
| Temperature, dynamic continuously flexing | -40 °C to +80 °C max. conductor temperature according to UL AWM |
| Temperature, dynamic continuously flexing max | 80 °C |
| Temperature, dynamic continuously flexing min | -40 °C |
| Flame-retardant | Yes |
| Flame retardance according to | IEC 60332-1-2 |
| UV-resistant | Yes |
| UV-resistant according to | DIN EN ISO 4892-2 method A |
| Weather-resistant | Yes |
| Weather-resistant according to | ISO 4892-2 |
| Ozone-resistant | Yes |
| Ozone-resistant according to | EN 50396, method B |
| Halogen-free | Yes |
| Halogen-free according to | VDE 0472-815 |
| Oil-resistant | Yes |
| Oil resistance according to | EN 50363-10-2 |
| PWIS-free | Yes |
| PWIS-free according to | VDMA 24364-B2-L |
| Mechanically resistant | Yes |
Certifications and standards
| CE marking | Yes |
|---|---|
| UL recognized | Yes |
| UL AWM certification | 21576 according to UL 758 (e-file number: E63634) |
| UL listed | No |
| cUR recognised | Yes |
| cUR certification | AWM I A according to CSA C22.2 No. 210 (80°C, 300V) (e-file number: E63634); AWM I B according to CSA C22.2 No. 210 (80°C, 300V) (e-file number: E63634); AWM II A according to CSA C22.2 No. 210 (80°C, 300V) (e-file number: E63634); AWM II B according to CSA C22.2 No. 210 (80°C, 300V) (e-file number: E63634) |
| cUL listed | No |
| CSA certified | No |
| VDE certified | No |
| DNV-certified | No |
Datasheets and certificates
- Data sheet: DB11139600EN.pdf
- UL approval: ZUE63634.pdf
- cUL approval: ZKE63634.pdf
- CE declaration of conformity: CE11139600EN.pdf
Manufacturer notes
- Inductance and operating capacitance are neither defined nor controlled electrical parameters. The specified values were determined by calculation and may deviate due to tolerances.
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.





Reviews
There are no reviews yet.