Article specifications
| Part no. | 48517 |
|---|---|
| Item description | HELUDATA® JE-LiYCY Bd PVC GREY 32 x 2 x 0,5 mm² |
| Sheath colour | grey (RAL 7032) |
| AWG, approx. | 20 |
| Outer diameter, approx. (mm) | 20,5 |
| Copper factor per km | 444,0 |
| Weight, approx. (kg/km) | 737,0 |
| Reaction to fire class | Eca |
| Metres per packaging unit | 500, 1000 |
| Custom cut lengths available | yes |
| EAN / GTIN | 4060892097072 |
| Customs tariff number | 85444995 |
Manufacturer technical information
PVC data cable in alignment with DIN VDE 0815
Temperature range
flexible -5°C to +50°C
fixed -30°C to +70°C
fixed -30°C to +70°C
Peak operating voltage
225 V (not for high power current installation purposes)
Test voltage core/core
500 V
Test voltage core/screen
2000 V
Conductor resistance at 20°C
max. 39.2 Ohm/km
Mutual capacitance core/core
at 800 Hz
2 - 4 pairs: approx. 120 pF/m
8 - 40 pairs: approx. 100 pF/m
2 - 4 pairs: approx. 120 pF/m
8 - 40 pairs: approx. 100 pF/m
Capacitive coupling k1
at 800 Hz, max. 200 pF/100m
Cable attenuation
at 800 Hz, 1.1 dB/km
(approx. value)
(approx. value)
Inductance
approx. 0.70 mH/km
Minimum bending radius
fixed 6x Outer-Ø
Cable Structure
- Copper wire bare, stranded
- Strand construction:
- 0.5 mm²: 7 x 0.3 mm
- Core insulation: semirigid PVC
- Core identification acc. to. DIN VDE 0815, colour coded
- Cores stranded in pairs with optimal lay lengths, 4 pairs stranded into bundles with optimal lay lengths, bundles stranded in layers with optimal lay lengths
- Foil wrapping
- Screen: braided screen of bare or tinned copper wires, approx. coverage 85%
- Outer sheath: PVC acc. to DIN VDE 0207-5 (compound type YM1)
- Sheath colour: see datasheet
Properties
- the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
Notes
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
- 2-pair cables: cores stranded to a star quad
- with blue sheathing for the installation of intrinsically safe systems (ignition protection type -i-) in explosion-endangered areas according to DIN VDE 0165-1 / DIN EN 60079-14 / IEC 60079-14, Section 16.2.2
Application
- The cables are used for the transmission of signals and measurements in symmetrical circuits for control technology, as well as for the transmission of information in data and process computer systems. They can be used in dry and damp operating areas, as well as in and under plaster and outdoors with fixed installation. Installation cables are not permitted for high voltage current installations or underground laying. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding.








Reviews
There are no reviews yet.