Benefits
- For the protection of people and property.
- Insulation integrity for up to 120 minutes under the effect of fire (classification PH120 according to DIN EN 50200). Guarantees functional integrity and power supply in the event of an emergency.
- Compliant with standards for use in railway vehicles: fire safety and cable design requirements according to DIN EN 50264-3-2, type MM; fire behaviour in accordance with DIN EN 45545-2, hazard level HL3.
- The cross-linked insulation and sheath materials promote longevity at high temperatures or with a high current load, and provide high dielectric strength.
- Halogen-free and highly flame retardant materials reduce the risk of flame propagation, high smoke density and toxic smoke in the event of a fire.
- Space-saving due to reduced wall thicknesses.
Applications
- For wiring safety-related components in railway vehicles.
- Typical application areas are emergency power circuits for alarm, lighting and communication purposes, which must maintain their function for a certain period of time in the event of a fire.
- For use in railway vehicles, for fixed installation and applications where limited movement is to be expected.
- Can be used in dry and damp conditions, and especially in harsh and oily environments.
- The cross-linked polymer compound is highly resistant to oils, fuels, alkalis and acids.
Product notes
- Further technical data: See data sheet or on request
Technical specifications
General information
| Product type | Railway cable |
|---|---|
| Weight | 53 kg/km |
| Copper index | 19.2 kg/km |
| Industry segment | Rolling Stock |
| customs code | 85444995 |
Electrical parameters
| Nominal voltage | U0/U: 300/500 V AC rms according to IEC |
|---|---|
| Maximum operating voltage Um | 600 V AC |
| Test voltage | 2 kV |
| Current rating according to | EN 50355 |
| Max. conductor resistance at 20°C | 20 Ω/km |
Product design
| Cable design abbreviations for railway vehicles | Type MM |
|---|---|
| Cable dimensions | 2X1 |
| Nominal conductor cross-section (metric) | 1 mm² |
| Conductor material | Tin-plated copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | No |
| Number of cores | 2 |
| Shielded | No |
| Nominal outer diameter | 6.5 mm |
| Cable shape | Round |
| Core insulation basic material | Halogen-free compound |
| Insulation colour | black |
| Core wrapping | MICA tape |
| Basic material of outer sheath | Halogen-free compound |
| Outer sheath colour | red |
| Core identification | Numbers |
| Conductor colour code | EN 50334; VDE 0293-1 |
Product features
| Application area | Fixed installation |
|---|---|
| Minimum bending radius, stationary | 4 x outer diameter |
| Minimum bending radius in mm, fixed installation | 26 mm |
| Temperature, fixed installation | -40 °C to +90 °C max. conductor temperature |
| Temperature, fixed installation max | 90 °C |
| Temperature, fixed installation min | -40 °C |
| Flame-retardant | Yes |
| Flame retardance according to | EN 50200; IEC 60332-1-2; IEC 60332-3-25 |
| Low smoke density according to | EN 50264-1; IEC 61034-2 |
| Low toxicity of combustion gases according to | EN 50264-1; EN 50305 |
| Corrosiveness of combustion gases according to | EN 50264-1; IEC 60754-2 |
| UV-resistant | No |
| Ozone-resistant | Yes |
| Ozone-resistant according to | EN 50264-3-1, method B; EN 50305 |
| Chemical resistant | Yes |
| Acid-resistant | Yes |
| Acid-resistant according to | EN 50264-3-1 |
| Alkali-resistant | Yes |
| Alkali-resistant according to | EN 50264-3-1 |
| Halogen-free | Yes |
| Halogen-free according to | IEC 60754-1; EN 60684-2 |
| Oil-resistant | Yes |
| Oil resistance according to | EN 50264-3-1 |
| Fuel-resistant | Yes |
| Fuel-resistant according to | EN 50264-3-1 |
Certifications and standards
| CE marking | No |
|---|---|
| VDE certified | No |
| Flame retardance tested according to UN/ECE-R118 | No |
| Fire protection tested for railway vehicles | Yes |
| Fire protection for railway vehicles hazard level | EN 45545-2 HL3 |
| Standard for railway vehicles | EN 50264-3-2 |
Datasheets and certificates
Manufacturer notes
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.







Reviews