Sale!

LAPP KN3L NiCr/Ni KCA 2X1,5 DIN oval – 0152005

Price on request

Ausgleichsleitung; KCA; DIN; GL-GL – oval; 2X1.5

Lieferlängen und Mindestmenge auf Anfrage.

Compensating cable; KCA; DIN; GL-GL – Oval; 2X1.5

Supply lengths and minimum quantity on request.

LAPP LENGTHS & PRICING

More length. Better value.

10–49 m
0%list price
50–99 m
−5%discount
100 m
−10%discount
Over 100 m
−15%discount

Your discount is based on metres per basket line.

Cuts of 10–20 m

Per cut, incl. VAT · added separately in the basket

No cutting fee above 20 m.
5 €
Select the length to check stock availability.
SKU: LAPP-0152005 Category: Brand:

Delivery time: 5–7 business days

Request an individual quote

Request a quote →

Delivery time and availability will be confirmed in your quote.

For longer lengths or custom cable lengths, please contact us.
Contact us / Request a quote ↗Product details are filled in automatically. Tell us the quantity or length you need.
Request a quote for this product

Request a quote with no obligation — no account needed.

LAPP KN3L NiCr/Ni KCA 2X1,5 DIN oval – 0152005
LAPP KN3L NiCr/Ni KCA 2X1,5 DIN oval – 0152005SKU: LAPP-0152005

We use your details to handle your enquiry. Privacy policy

KN3L NiCr/Ni KCA 2X1,5 DIN oval

Ausgleichsleitung; KCA; DIN; GL-GL – oval; 2X1.5

Lieferlängen und Mindestbestellmengen sind eingeschränkt. Bitte ein individuelles Angebot anfragen.

Vorteile

  • Eindeutige Identifizierung des Leitungstyps anhand des Artikelnamens. Thermoelementleitungen: Kürzel des Thermopaars („K“, „N“, …). Thermoleitungen: Kürzel des Thermopaars ergänzt um ein X („JX“, „LX“, …). Ausgleichsleitungen: Kürzel des Thermopaars ergänzt um ein C und ggf. um ein Kurzzeichen für unterschiedliche Ausgleichsmaterialien („KCA“, „RCB/SCB“, …).
  • Thermoelementleitungen können sowohl direkt als Thermopaar in einem Thermoelement verwendet werden als auch als zuverlässige Verbindung zwischen der Anschlussstelle und der Vergleichsstelle.
  • Thermo- und Anschlussleitungen ermöglichen eine zuverlässige Verbindung zwischen der Anschlussstelle und der Vergleichsstelle.
  • Thermoelement- und Thermoleitungen bestehen aus der gleichen Legierung wie das Thermopaar. Sie entsprechen der Genauigkeitsklasse 1 oder 2 nach IEC 60584, wobei Klasse 1 die höhere Genauigkeit bietet.
  • Thermoelementleitungen sind für den Einsatz bis zur maximalen Temperatur des Thermopaars ausgelegt, während Thermoleitungen im genormten Anwendungsbereich geeicht sind.
  • Ausgleichsleitungen verwenden Materialien, die ähnliche thermoelektrische Eigenschaften wie das Thermoelement haben, aber kostengünstiger sind. Sie sind im genormten Anwendungsbereich geeicht und entsprechen der Genauigkeitsklasse 2 gemäß IEC 60584.
  • Vielzahl an Abmessungen und Legierungen für breites Anwendungsspektrum verfügbar.
  • In Varianten für Anwendungen mit Temperaturen bis zu +1200 °C sowie für Anwendungen mit erhöhter Strahlungsbelastung, wie z. B. medizinische Anwendungen, erhältlich.

Anwendungsbereiche

  • Zur Übertragung der Thermospannung von Thermoelementen in der Temperaturmesstechnik.
  • Zur Temperaturmessung an Stellen, an denen keine kontaktlose Temperaturmessung möglich oder sinnvoll ist.
  • Zur Verwendung mit den Schutzschläuchen SILVYN® HIPROJACKET und SILVYN® SSUE.
  • Zur Verwendung mit dem Kennzeichnungssystem FLEXIMARK® Edelstahl FCC.
  • Zur festen Verlegung und gelegentlichen Bewegung.

Produkthinweise

  • Handels-Produkt, kein LAPP-Produkt.

Technische Daten

Allgemeine Informationen
Produkttyp Ausgleichsleitung
Gewicht 50 kg/km
Industrie Segment Baumaschinen; Werkzeugmaschinen
Zolltarifnummer 85444993
Produktaufbau
Thermo- und Ausgleichsleitung Typ KCA
Leitungsabmessung 2X1.5
Leiternennquerschnitt (metrisch) 1,5 mm²
Leiteraufbau 48 x 0,20mm
Einschließlich Schutzleiter Nein
Anzahl Adern 2
Geschirmt Nein
Mit Bewehrung Nein
Min. Aussendurchmesser 2,7 mm
Max. Aussendurchmesser 5,1 mm
Leitungsform oval
Thermo- und Ausgleichsleitung Aufbau GL-GL – oval
Grundmaterial der Aderisolation Glasseide
Grundmaterial der Aderisolation, Kurzform GL
Grundmaterial des Außenmantels Glasseide
Grundmaterial des Außenmantels, Kurzform GL
Außenmantelfarbe grün
Aderidentifizierung Farben
Ader Farbcode DIN 43710
Thermo- und Ausgleichsleitung Farbcode DIN
Produkteigenschaften
Einsatzgebiet flexibel; feste Verlegung
Minimaler Biegeradius, festverlegt 12 x Außendurchmesser
Minimaler Biegeradius in mm, festverlegt 61,2 mm
Minimaler Biegeradius, gelegentlich bewegt 12 x Außendurchmesser
Minimaler Biegeradius in mm, gelegentlich bewegt 61,2 mm
Temperatur, fest verlegt -50 °C bis 200 °C max. Leitertemperatur
Temperatur, fest verlegt max 200 °C
Temperatur, fest verlegt min -50 °C
Temperatur, gelegentlich bewegt -25 °C bis 200 °C max. Leitertemperatur
Temperatur, gelegentlich bewegt max 200 °C
Temperatur, gelegentlich bewegt min -25 °C
Flammwidrig Ja
Flammwidrigkeit nach IEC 60332-1-2
UV-beständig Nein
Chemisch beständig Nein
Halogenfrei Ja
Ölbeständig Nein
LABS-frei Nein
Zertifizierungen und Normen
CE gekennzeichnet Ja
EAC zertifiziert Ja
EAC Zertifizierungsnummer ЕАЭС N RU Д-DE.АЮ64.В.00130/20
Flammwidrigkeit nach UN/ECE-R118 getestet Nein

Datenblätter und Zertifikate

Herstellerhinweise
  • Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie – soweit verfügbar und zur Veröffentlichung freigegeben- auf Anfrage.
  • Die Fotografien und Grafiken sind nicht maßstäblich und keine detailgetreuen Abbildungen der jeweiligen Produkte.
  • Sofern anwendbar, handelt es sich um den Vollmetallpreis ohne Zuschläge und MwSt. Verkauf nur an Firmenkunden.
Lieferlängen & Bestellbedingungen
Mindestbestellmenge 500 M
Bestellintervall 0 M
Individueller Zuschnitt beim Hersteller Ja
Hersteller-Standardlängen 100 / 500 / 1000 M

Offizielle LAPP Produktinformationen, Datenblatt und Zertifikate

Hersteller-Nennwerte. Produktabbildung repräsentativ; Bauform, Farbe und Abmessungen können je Artikel abweichen. Gewichte gelten für das Kabel ohne Verpackung und Trommel. Versand nach verpacktem Gewicht und Maßen.

KN3L NiCr/Ni KCA 2X1,5 DIN oval

Compensating cable; KCA; DIN; GL-GL – Oval; 2X1.5

Supply lengths and minimum order quantities are restricted. Please request an individual quotation.

Benefits

  • Clear identification of the cable type based on the article name. Thermocouple cables: Abbreviation of the thermocouple („K“, „N“, …). Thermoelectric cables: Abbreviation of the thermocouple supplemented by an X („JX“, „LX“, …). Compensating cables: Abbreviation of the thermocouple supplemented by a C and, if applicable, an abbreviation for different compensating materials („KCA“, „RCB/SCB“, …).
  • Thermocouple cables can be used both directly as a thermocouple in a thermocouple element and as a reliable connection between the connection point and the reference junction.
  • Thermoelectric and power cables provide a reliable connection between the connection point and the cold junction.
  • Thermocouple and thermoelectric cables are made of the same alloy as the thermocouple. They correspond to accuracy class 1 or 2 according to IEC 60584, whereby class 1 offers the higher accuracy.
  • Thermocouple cables are designed for use up to the maximum temperature of the thermocouple, while thermoelectric cables are calibrated in the standardised application range.
  • Compensating cables use materials that have similar thermoelectric properties to the thermocouple element but are less expensive. They are calibrated in the standardised application range and correspond to accuracy class 2 in accordance with IEC 60584.
  • Numerous dimensions and alloys available for a wide range of applications.
  • Available in variants for applications with temperatures up to +1200 °C as well as for applications with increased radiation exposure, such as medical applications.

Applications

  • For transmitting the thermoelectric voltage of thermocouple elements in temperature measurement technology.
  • For temperature measurement in places where non-contact temperature measurement is not possible or practical.
  • For use with the SILVYN® HIPROJACKET and SILVYN® SSUE protective conduits.
  • For use with the FLEXIMARK® stainless steel FCC marking system.
  • For fixed installation and occasional movement.

Product notes

  • Trade product, not a LAPP product.

Technical specifications

General information
Product type Compensating cable
Weight 50 kg/km
Industry segment Construction Machinery; Machine tools
customs code 85444993
Product design
Extension and compensating cable type KCA
Cable dimensions 2X1.5
Nominal conductor cross-section (metric) 1.5 mm²
Conductor design 48 x 0.20 mm
Including protective earth No
Number of cores 2
Shielded No
With armouring No
Min. outer diameter 2.7 mm
Max. outer diameter 5.1 mm
Cable shape Oval
Extension and compensating cables design GL-GL – Oval
Core insulation basic material Glass fibre
Core insulation basic material, short form GL
Basic material of outer sheath Glass fibre
Basic material of outer sheath, short form GL
Outer sheath colour green
Core identification Colours
Conductor colour code DIN 43710
Extension and compensating cable colour code DIN
Product features
Application area Flexible; Fixed installation
Minimum bending radius, stationary 12 x outer diameter
Minimum bending radius in mm, fixed installation 61.2 mm
Minimum bending radius, occasionally flexing 12 x outer diameter
Minimum bending radius in mm, occasionally flexing 61.2 mm
Temperature, fixed installation -50 °C to 200 °C max. conductor temperature
Temperature, fixed installation max 200 °C
Temperature, fixed installation min -50 °C
max. conductor temperature, occasionally moved -25 °C to 200 °C max. conductor temperature
Temperature, occasionally moved max 200 °C
Temperature, occasionally moved min -25 °C
Flame-retardant Yes
Flame retardance according to IEC 60332-1-2
UV-resistant No
Chemical resistant No
Halogen-free Yes
Oil-resistant No
PWIS-free No
Certifications and standards
CE marking Yes
EAC-certified Yes
EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20
Flame retardance tested according to UN/ECE-R118 No

Datasheets and certificates

Manufacturer notes
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
Supply lengths & ordering conditions
Minimum order quantity 500 M
Order quantity interval 0 M
Manufacturer individual cut lengths Yes
Manufacturer standard lengths 100 / 500 / 1000 M

Official LAPP product information, datasheet and certificates

Manufacturer nominal values. Representative product image; construction, colour and dimensions may vary by article. Cable weights exclude packaging and reels. Shipping depends on packed weight and dimensions.

Weight N/A
laenge

10 m, 20 m, 50 m, 100 m

Cross-section

1,5 mm²

Aderzahl

2

Colour

grün

Shielding

Nein

Reviews

There are no reviews yet.

You must purchase this product before you can write a review. Sign in with the account you used to place your order.

Shopping Cart
Scroll to Top
WhatsApp