Article specifications
| Part no. | 400117 |
|---|---|
| Item description | HELUSOUND® 600 FRNC black 2 x 2,5 mm² |
| AWG, approx. | 14 |
| Outer diameter, approx. (mm) | 7,5 |
| Copper factor per km | 48,0 |
| Weight, approx. (kg/km) | 115,2 |
| Reaction to fire class | Eca |
| Metres per packaging unit | 100, 500, 1000 |
| Custom cut lengths available | yes |
| EAN / GTIN | 4060892305160 |
| Customs tariff number | 85444995 |
Manufacturer technical information
Speaker cable
Temperature range
flexible -5°C to +70°C
fixed -40°C to +70°C
fixed -40°C to +70°C
Test voltage core/core
1000 V
Minimum bending radius
flexible 8x Outer-Ø
fixed 5x Outer-Ø
fixed 5x Outer-Ø
Cable Structure
- Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
- Core insulation: halogen-free, flame retardant compound (FRNC)
- Core identification: colour coded
- x = without protective conductor
- Cores stranded with optimal lay lengths
- Outer sheath: halogen-free, flame retardant compound (FRNC)
- Sheath colour: black (RAL 9005)
- Length marking: in metres
Properties
- resistant to: UV radiation
- halogen-free
- flame-retardant, low smoke development
Tests
- halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
- corrosiveness of combustion gases acc. to DIN VDE 0482-754-2 / DIN EN 60754-2 / IEC 60754-2
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
- bundle fire test acc. to DIN VDE 0482-332-3-22 / DIN EN 60332-3-22 / IEC 60332-3-22
- smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
Notes
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
Application
- The HELUSOUND® 600 FRNC is the safe solution for higher safety requirements in the event of fire. This cable is used when halogen-free materials are required. The classic areas of application include Installations in public buildings, theaters, hospitals, schools, airports. The use of flame-retardant, halogen-free core and sheath material results in low smoke development, and there is no corrosion damage due to released gases and vapors and no fire propagation in the event of local flame exposure.




Reviews
There are no reviews yet.