Sale!

LAPP J GL-GL-S Fe/CuNi 2×0.22 IEC – 1161004

Price on request

Thermoelementleitung; J; IEC; GL-GL-S-rund; 2X0.22

Lieferlängen und Mindestmenge auf Anfrage.

Thermocouple cable; J; IEC; GL-GL-S-Round; 2X0.22

Supply lengths and minimum quantity on request.

LAPP LENGTHS & PRICING

More length. Better value.

10–49 m
0%list price
50–99 m
−5%discount
100 m
−10%discount
Over 100 m
−15%discount

Your discount is based on metres per basket line.

Cuts of 10–20 m

Per cut, incl. VAT · added separately in the basket

No cutting fee above 20 m.
5 €
Select the length to check stock availability.
SKU: LAPP-1161004 Category: Brand:

Delivery time: 5–7 business days

Request an individual quote

Request a quote →

Delivery time and availability will be confirmed in your quote.

For longer lengths or custom cable lengths, please contact us.
Contact us / Request a quote ↗Product details are filled in automatically. Tell us the quantity or length you need.
Request a quote for this product

Request a quote with no obligation — no account needed.

LAPP J GL-GL-S Fe/CuNi 2x0.22 IEC – 1161004
LAPP J GL-GL-S Fe/CuNi 2x0.22 IEC – 1161004SKU: LAPP-1161004

We use your details to handle your enquiry. Privacy policy

J GL-GL-S Fe/CuNi 2×0.22 IEC

Thermoelementleitung; J; IEC; GL-GL-S-rund; 2X0.22

Lieferlängen und Mindestbestellmengen sind eingeschränkt. Bitte ein individuelles Angebot anfragen.

Vorteile

  • Eindeutige Identifizierung des Leitungstyps anhand des Artikelnamens. Thermoelementleitungen: Kürzel des Thermopaars („K“, „N“, …). Thermoleitungen: Kürzel des Thermopaars ergänzt um ein X („JX“, „LX“, …). Ausgleichsleitungen: Kürzel des Thermopaars ergänzt um ein C und ggf. um ein Kurzzeichen für unterschiedliche Ausgleichsmaterialien („KCA“, „RCB/SCB“, …).
  • Thermoelementleitungen können sowohl direkt als Thermopaar in einem Thermoelement verwendet werden als auch als zuverlässige Verbindung zwischen der Anschlussstelle und der Vergleichsstelle.
  • Thermo- und Anschlussleitungen ermöglichen eine zuverlässige Verbindung zwischen der Anschlussstelle und der Vergleichsstelle.
  • Thermoelement- und Thermoleitungen bestehen aus der gleichen Legierung wie das Thermopaar. Sie entsprechen der Genauigkeitsklasse 1 oder 2 nach IEC 60584, wobei Klasse 1 die höhere Genauigkeit bietet.
  • Thermoelementleitungen sind für den Einsatz bis zur maximalen Temperatur des Thermopaars ausgelegt, während Thermoleitungen im genormten Anwendungsbereich geeicht sind.
  • Ausgleichsleitungen verwenden Materialien, die ähnliche thermoelektrische Eigenschaften wie das Thermoelement haben, aber kostengünstiger sind. Sie sind im genormten Anwendungsbereich geeicht und entsprechen der Genauigkeitsklasse 2 gemäß IEC 60584.
  • Vielzahl an Abmessungen und Legierungen für breites Anwendungsspektrum verfügbar.
  • In Varianten für Anwendungen mit Temperaturen bis zu +1200 °C sowie für Anwendungen mit erhöhter Strahlungsbelastung, wie z. B. medizinische Anwendungen, erhältlich.

Anwendungsbereiche

  • Zur Übertragung der Thermospannung von Thermoelementen in der Temperaturmesstechnik.
  • Zur Temperaturmessung an Stellen, an denen keine kontaktlose Temperaturmessung möglich oder sinnvoll ist.
  • Zur Verwendung mit den Schutzschläuchen SILVYN® HIPROJACKET und SILVYN® SSUE.
  • Zur Verwendung mit dem Kennzeichnungssystem FLEXIMARK® Edelstahl FCC.
  • Zur festen Verlegung und gelegentlichen Bewegung.

Produkthinweise

  • Handels-Produkt, kein LAPP-Produkt.

Technische Daten

Allgemeine Informationen
Produkttyp Thermoelementleitung
Gewicht 27 kg/km
Industrie Segment Baumaschinen; Werkzeugmaschinen
Zolltarifnummer 85444993
Elektrische Kennwerte
Prüfspannung 0.5 kV
Produktaufbau
Thermo- und Ausgleichsleitung Typ J
Leitungsabmessung 2X0.22
Leiternennquerschnitt (metrisch) 0,22 mm²
Leiteraufbau 7 x 0,20mm
Einschließlich Schutzleiter Nein
Anzahl Adern 2
Geschirmt Nein
Mit Bewehrung Ja
Bewehrungsart verzinktes Stahldrahtgeflecht
Nennaussendurchmesser 3,5 mm
Leitungsform rund
Thermo- und Ausgleichsleitung Aufbau GL-GL-S-rund
Grundmaterial der Aderisolation Glasseide
Grundmaterial der Aderisolation, Kurzform GL
Grundmaterial des Innenmantels Glasseide
Grundmaterial des Innenmantels Kurzform GL
Innenmantel Farbe schwarz
Aderidentifizierung Farben
Ader Farbcode IEC 60584-3
Thermo- und Ausgleichsleitung Farbcode IEC
Produkteigenschaften
Einsatzgebiet flexibel; feste Verlegung
Minimaler Biegeradius, festverlegt 7,5 x Außendurchmesser
Minimaler Biegeradius in mm, festverlegt 26,3 mm
Minimaler Biegeradius, gelegentlich bewegt 15 x Außendurchmesser
Minimaler Biegeradius in mm, gelegentlich bewegt 52,5 mm
Temperatur, fest verlegt -50 °C bis 350 °C max. Leitertemperatur
Temperatur, fest verlegt max 350 °C
Temperatur, fest verlegt min -50 °C
Temperatur, gelegentlich bewegt -25 °C bis 350 °C max. Leitertemperatur
Temperatur, gelegentlich bewegt max 350 °C
Temperatur, gelegentlich bewegt min -25 °C
Flammwidrig Ja
UV-beständig Nein
Chemisch beständig Nein
Halogenfrei Ja
Ölbeständig Nein
LABS-frei Nein
Zertifizierungen und Normen
CE gekennzeichnet Ja
Flammwidrigkeit nach UN/ECE-R118 getestet Nein

Datenblätter und Zertifikate

Herstellerhinweise
  • Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie – soweit verfügbar und zur Veröffentlichung freigegeben- auf Anfrage.
  • Die Fotografien und Grafiken sind nicht maßstäblich und keine detailgetreuen Abbildungen der jeweiligen Produkte.
  • Sofern anwendbar, handelt es sich um den Vollmetallpreis ohne Zuschläge und MwSt. Verkauf nur an Firmenkunden.
Lieferlängen & Bestellbedingungen
Mindestbestellmenge 500 M
Bestellintervall 0 M
Individueller Zuschnitt beim Hersteller Ja
Hersteller-Standardlängen 100 / 500 / 1000 M

Offizielle LAPP Produktinformationen, Datenblatt und Zertifikate

Hersteller-Nennwerte. Produktabbildung repräsentativ; Bauform, Farbe und Abmessungen können je Artikel abweichen. Gewichte gelten für das Kabel ohne Verpackung und Trommel. Versand nach verpacktem Gewicht und Maßen.

J GL-GL-S Fe/CuNi 2×0.22 IEC

Thermocouple cable; J; IEC; GL-GL-S-Round; 2X0.22

Supply lengths and minimum order quantities are restricted. Please request an individual quotation.

Benefits

  • Clear identification of the cable type based on the article name. Thermocouple cables: Abbreviation of the thermocouple („K“, „N“, …). Thermoelectric cables: Abbreviation of the thermocouple supplemented by an X („JX“, „LX“, …). Compensating cables: Abbreviation of the thermocouple supplemented by a C and, if applicable, an abbreviation for different compensating materials („KCA“, „RCB/SCB“, …).
  • Thermocouple cables can be used both directly as a thermocouple in a thermocouple element and as a reliable connection between the connection point and the reference junction.
  • Thermoelectric and power cables provide a reliable connection between the connection point and the cold junction.
  • Thermocouple and thermoelectric cables are made of the same alloy as the thermocouple. They correspond to accuracy class 1 or 2 according to IEC 60584, whereby class 1 offers the higher accuracy.
  • Thermocouple cables are designed for use up to the maximum temperature of the thermocouple, while thermoelectric cables are calibrated in the standardised application range.
  • Compensating cables use materials that have similar thermoelectric properties to the thermocouple element but are less expensive. They are calibrated in the standardised application range and correspond to accuracy class 2 in accordance with IEC 60584.
  • Numerous dimensions and alloys available for a wide range of applications.
  • Available in variants for applications with temperatures up to +1200 °C as well as for applications with increased radiation exposure, such as medical applications.

Applications

  • For transmitting the thermoelectric voltage of thermocouple elements in temperature measurement technology.
  • For temperature measurement in places where non-contact temperature measurement is not possible or practical.
  • For use with the SILVYN® HIPROJACKET and SILVYN® SSUE protective conduits.
  • For use with the FLEXIMARK® stainless steel FCC marking system.
  • For fixed installation and occasional movement.

Product notes

  • Trade product, not a LAPP product.

Technical specifications

General information
Product type Thermocouple cable
Weight 27 kg/km
Industry segment Construction Machinery; Machine tools
customs code 85444993
Electrical parameters
Test voltage 0.5 kV
Product design
Extension and compensating cable type J
Cable dimensions 2X0.22
Nominal conductor cross-section (metric) 0.22 mm²
Conductor design 7 x 0.20 mm
Including protective earth No
Number of cores 2
Shielded No
With armouring Yes
Armouring type Galvanised steel wire braiding
Nominal outer diameter 3.5 mm
Cable shape Round
Extension and compensating cables design GL-GL-S-Round
Core insulation basic material Glass fibre
Core insulation basic material, short form GL
Basic material of inner sheath Glass fibre
base material inner sheath shortname GL
Inner sheath colour black
Core identification Colours
Conductor colour code IEC 60584-3
Extension and compensating cable colour code IEC
Product features
Application area Flexible; Fixed installation
Minimum bending radius, stationary 7.5 x outer diameter
Minimum bending radius in mm, fixed installation 26.3 mm
Minimum bending radius, occasionally flexing 15 x outer diameter
Minimum bending radius in mm, occasionally flexing 52.5 mm
Temperature, fixed installation -50 °C to 350 °C max. conductor temperature
Temperature, fixed installation max 350 °C
Temperature, fixed installation min -50 °C
max. conductor temperature, occasionally moved -25 °C to 350 °C max. conductor temperature
Temperature, occasionally moved max 350 °C
Temperature, occasionally moved min -25 °C
Flame-retardant Yes
UV-resistant No
Chemical resistant No
Halogen-free Yes
Oil-resistant No
PWIS-free No
Certifications and standards
CE marking Yes
Flame retardance tested according to UN/ECE-R118 No

Datasheets and certificates

Manufacturer notes
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
Supply lengths & ordering conditions
Minimum order quantity 500 M
Order quantity interval 0 M
Manufacturer individual cut lengths Yes
Manufacturer standard lengths 100 / 500 / 1000 M

Official LAPP product information, datasheet and certificates

Manufacturer nominal values. Representative product image; construction, colour and dimensions may vary by article. Cable weights exclude packaging and reels. Shipping depends on packed weight and dimensions.

Weight N/A
laenge

10 m, 20 m, 50 m, 100 m

Cross-section

0,22 mm²

Aderzahl

2

Shielding

Nein

Reviews

There are no reviews yet.

You must purchase this product before you can write a review. Sign in with the account you used to place your order.

Shopping Cart
Scroll to Top
WhatsApp