Power and control cable; 3G1.5; U0/U: 300/500 V; Core identification: Colours and numbers; UL listed; Flexible
Benefits
- Cable specially developed for use in the USA.
- UL-listed according to type TC (Tray Cable) or TC ER (Tray Cable for Exposed Run) and STOOW (extra-hard usage flexible cord (600 V)).
- Outer sheath made of special thermoplastic polymer for heavy industrial stress and improved longevity.
- Core insulation made of special PVC compound.
- Particularly oil-resistant and flame retardant.
- High thermal resistance and good cold flexibility.
Applications
- Suitable as a flexible power or extension cable.
- For unprotected installation and occasionally moving use in the end consumer circuit.
- For open installation in cable trays without a protective conduit.
- For occasionally moving use in potentially explosive atmospheres in the USA.
- The cable design and the outer sheath make it suitable for use in harsh, oily industrial environments.
- Suitable for outdoor use, subject to the temperature range.
- For universal use in Europe for the wiring of machine-internal and cross-plant control circuits.
- In Europe for fixed installation and occasional movement.
Technical specifications
General information
| Brand | ÖLFLEX® |
|---|---|
| Product type | Power and control cable |
| Weight | 110 kg/km |
| Copper index | 43.16 kg/km |
| customs code | 85444995 |
Electrical parameters
| Nominal voltage | U0/U: 300/500 V AC rms according to IEC |
|---|---|
| Rated voltage | 600 V AC rms according to UL TC; 600 V AC rms according to UL STOOW; 600 V AC rms according to c(UL) CIC/TC; 600 V AC rms according to cUL STOOW; 600 V AC rms according to CSA AWM |
| Test voltage | 2 kV |
| Current rating according to | NEC / NFPA 70; NFPA 79; IEC 60364-5-52 |
| Max. conductor resistance at 20°C | 13.3 Ω/km |
Product design
| Cable dimensions | 3G1.5 |
|---|---|
| Nominal conductor cross-section (metric) | 1.5 mm² |
| Nominal conductor cross-section (AWG) | 16 AWG |
| Leading conductor cross-section | mm² |
| Conductor material | Bare copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | Yes |
| Number of cores | 3 |
| Shielded | No |
| Nominal core diameter | 3.18 mm |
| Min. outer diameter | 9.88 mm |
| Nominal outer diameter | 10.1 mm |
| Max. outer diameter | 10.52 mm |
| Cable shape | Round |
| Core insulation basic material | Polyvinylchloride |
| Core insulation basic material, short form | PVC |
| Basic material of outer sheath | Thermoplastic |
| Outer sheath colour | black |
| Core identification | Colours and numbers |
Product features
| Application area | Flexible; Fixed installation |
|---|---|
| For torsional load | No |
| Suitable for use in accordance with NEC chapter 5 | Class I Division 1 |
| Minimum bending radius, stationary | 4 x outer diameter |
| Minimum bending radius in mm, fixed installation | 42.1 mm |
| Minimum bending radius, occasionally flexing | 4 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 42.1 mm |
| Temperature, fixed installation | -40 °C to 105 °C max. conductor temperature; -25 °C to 90 °C max. conductor temperature according to UL/CSA TC; -40 °C to 90 °C max. conductor temperature according to CSA AWM |
| Temperature, fixed installation max | 105 °C |
| Temperature, fixed installation min | -40 °C |
| max. conductor temperature, occasionally moved | -25 °C to 105 °C max. conductor temperature; -25 °C to 90 °C max. conductor temperature according to UL STOOW; -25 °C to 90 °C max. conductor temperature according to CSA AWM |
| Temperature, occasionally moved max | 105 °C |
| Temperature, occasionally moved min | -25 °C |
| Storage temperature min. | -40 °C |
| Max. storage temperature | 40 °C |
| Flame-retardant | Yes |
| Flame retardance according to | UL Vertical-Tray Flame Test; CSA FT4; IEC 60332-3-24 |
| UV-resistant | Yes |
| UV-resistant according to | UL sunlight resistant; EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use) |
| Weather-resistant | Yes |
| Ozone-resistant | Yes |
| Halogen-free | No |
| Oil-resistant | Yes |
| Oil resistance according to | UL OILRES I; UL OILRES II; CSA C22.2 No. 210-15 |
| Water-resistant | Yes |
| Mechanically resistant | Yes |
Certifications and standards
| CE marking | Yes |
|---|---|
| UL recognized | No |
| UL listed | Yes |
| UL certification | UL TC-ER according to UL 1277 (e-file number: E171371); UL STOOW according to UL 62 (e-file number: E146118) |
| cUR recognised | No |
| cUL listed | Yes |
| cUL certification | cUL CIC/TC 600V according to CSA C22.2 No. 239 / CSA C22.2 No. 230 (e-file number: E171371); cUL STOOW according to CSA C22.2 No. 49 (e-file number: E146118) |
| CSA certified | Yes |
| CSA certification | AWM I A according to CSA C22.2 No. 210; AWM I B according to CSA C22.2 No. 210; AWM II A according to CSA C22.2 No. 210; AWM II B according to CSA C22.2 No. 210 |
| VDE certified | No |
| HAR certified | No |
| Ecolab certified | No |
Datasheets and certificates
Manufacturer notes
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.




Reviews
There are no reviews yet.