Benefits
- Power supply for large electric drives possible.
- Halogen-free and highly flame retardant materials reduce the risk of flame propagation, high smoke density and toxic smoke in the event of a fire.
- Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
- Ideal protection against electromagnetic interference thanks to double shielding made of aluminium-laminated foil and copper stranded shielding with a high degree of coverage.
- Low-capacitance XLPE core insulation with outstanding electrical properties enables long transmission paths.
- Variants with balanced cable design and three-part protective earth largely prevent the generation of harmful currents on the motor bearing. A reduction in motor bearing damage contributes to the longevity of electric motors.
- Available as a 4-core variant and 3+3 balanced variant.
Applications
- For connecting frequency converters and motors.
- For fixed installation and occasional movement.
- Can be used in dry, damp and wet environments.
- Suitable for medium mechanical stress.
- Suitable for outdoor use, subject to the temperature range.
Technical specifications
General information
| Brand | ÖLFLEX® |
|---|---|
| Product type | Motor connection cable |
| Weight | 9420 kg/km |
| Copper index | 7639 kg/km |
| Industry segment | Agricultural & Farm Machinery; Assembly Machines; Automotive; Construction Machinery; Power Grids; Food & Beverage; HVAC; Lifts & Elevators; Machine tools; Ships & boats |
| customs code | 85444999 |
Electrical parameters
| Nominal voltage | U0/U: 0,6/1 kV AC rms according to IEC |
|---|---|
| Test voltage core/core | 4 kV |
| Test voltage core/screening | 4 kV |
| Current rating according to | VDE 0298-4 |
| Short-circuit temperature [5s] | 250 °C |
| Max. conductor resistance at 20°C | 0.106 Ω/km |
Product design
| Low-capacitance motor cable type | 2XSLCH-JB |
|---|---|
| Conductor number/size | 4G185 |
| Nominal conductor cross-section (metric) | 185 mm² |
| Conductor material | Bare copper |
| Conductor design | IEC 60228 class 5: fine-wire |
| Including protective earth | Yes |
| Number of cores | 4 |
| Cable element 1 | Power core: 4G185 |
| Stranding type | Layered stranding |
| Shielded | Yes |
| Type of overall screening | Aluminium-laminated plastic foil; Tin-plated copper braiding |
| Nominal outer diameter | 57.6 mm |
| Cable shape | Round |
| Core insulation basic material | Cross-linked polyethylene |
| Core insulation basic material, short form | XLPE |
| Basic material of outer sheath | Halogen-free compound |
| Basic material of outer sheath, short form | HFFR |
| Outer sheath colour | black |
| Cable sheath RAL colour | RAL 9005 |
| Core identification | Colours |
| Conductor colour code | VDE 0293-308 |
Product features
| Application area | Flexible; Fixed installation |
|---|---|
| Minimum bending radius, stationary | 4 x outer diameter |
| Minimum bending radius in mm, fixed installation | 230.4 mm |
| Minimum bending radius, occasionally flexing | 15 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 864 mm |
| Temperature, fixed installation | -40 °C to 90 °C max. conductor temperature |
| Temperature, fixed installation max | 90 °C |
| Temperature, fixed installation min | -40 °C |
| max. conductor temperature, occasionally moved | -15 °C to 90 °C max. conductor temperature |
| Temperature, occasionally moved max | 90 °C |
| Temperature, occasionally moved min | -15 °C |
| Flame-retardant | Yes |
| Flame retardance according to | IEC 60332-1-2; IEC 60332-3-24 |
| Low smoke density according to | IEC 61034-2 |
| Low toxicity of combustion gases according to | EN 50264-1; EN 50305; EN 50306-1 (≤ 3) |
| Corrosiveness of combustion gases according to | IEC 60754-2 |
| UV-resistant | Yes |
| UV-resistant according to | EN ISO 4892-2, method A (colour change permitted); EN 50620; EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use) |
| Halogen-free | Yes |
| Halogen-free according to | IEC 60754-1 |
| Oil-resistant | No |
| PWIS-free | Yes |
| PWIS-free according to | VDMA 24364-B2-L |
| Low capacitance | Yes |
Certifications and standards
| CE marking | Yes |
|---|---|
| EAC-certified | Yes |
| EAC certification number | ЕАЭС RU С-DE.АЮ64.В.00091/19 |
| CPR fire class | Dca |
| CPR smoke density | s2 |
| CPR drip behaviour | d2 |
| CPR acidity | a1 |
| Flame retardance tested according to UN/ECE-R118 | No |
Datasheets and certificates
- Data sheet: DB1133500EN.pdf
- Technical table: T9_Core ID code as per VDE colour code_int.pdf
- Installation notes: lapp_application-note_emc-compliant-connection_2024_en.pdf
- CE declaration of conformity: CE1133500EN.pdf
- CPR declaration of performance: UILCPRDOP19_1133500-1EN.pdf
Manufacturer notes
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.





Reviews
There are no reviews yet.