Sale!

LAPP ÖLFLEX® SERVO 2XSLCY-JB 4G150 – 1133612

Price on request

Motoranschlussleitung; 4G150; U0/U: 0,6/1 kV; PVC; Geschirmt; UL recognized; flexibel

Lieferlängen und Mindestmenge auf Anfrage.

Motor connection cable; 4G150; U0/U: 0,6/1 kV; PVC; Shielded; UL recognized; Flexible

Supply lengths and minimum quantity on request.

LAPP LENGTHS & PRICING

More length. Better value.

10–49 m
0%list price
50–99 m
−5%discount
100 m
−10%discount
Over 100 m
−15%discount

Your discount is based on metres per basket line.

Cuts of 10–20 m

Per cut, incl. VAT · added separately in the basket

No cutting fee above 20 m.
5 €
Select the length to check stock availability.
SKU: LAPP-1133612 Category: Brand:

Delivery time: 5–7 business days

Request an individual quote

Request a quote →

Delivery time and availability will be confirmed in your quote.

For longer lengths or custom cable lengths, please contact us.
Contact us / Request a quote ↗Product details are filled in automatically. Tell us the quantity or length you need.
Request a quote for this product

Request a quote with no obligation — no account needed.

LAPP ÖLFLEX® SERVO 2XSLCY-JB 4G150 – 1133612
LAPP ÖLFLEX® SERVO 2XSLCY-JB 4G150 – 1133612SKU: LAPP-1133612

We use your details to handle your enquiry. Privacy policy

ÖLFLEX® SERVO 2XSLCY-JB 4G150

Motoranschlussleitung; 4G150; U0/U: 0,6/1 kV; PVC; Geschirmt; UL recognized; flexibel

Lieferlängen und Mindestbestellmengen sind eingeschränkt. Bitte ein individuelles Angebot anfragen.

Vorteile

  • Energieversorgung großer Elektroantriebe möglich.
  • Varianten mit erdsymmetrischem Leitungsaufbau und gedritteltem Schutzleiter vermeiden in hohem Maße die Entstehung schädlicher Ströme am Motorlager. Eine Reduktion von Motorlagerschäden trägt zur Langlebigkeit von Elektromotoren bei.
  • Idealer Schutz vor elektromagnetischer Störung durch doppelte Schirmung aus aluminiumkaschierter Folie und Kupferabschirmgeflecht mit hohem Bedeckungsgrad.
  • Kapazitätsarme XLPE-Aderisolation mit herausragenden elektrischen Eigenschaften ermöglicht lange Übertragungswege.
  • Verbesserte Aderisolation erlaubt Leitertemperaturen von bis zu +90 °C und somit vielzählige Einsatzmöglichkeiten.
  • Klassifiziertes Brandverhalten gemäß EU-Richtlinie 305/2011 (BauPVO/CPR) mit Artikelnummer-Auswahl auf der LAPP-Website.
  • UL-/CSA-Zertifizierung gemäß Technischen Daten ermöglicht Verwendung des Produkts im nordamerikanischen Raum.
  • Produkt mit Mehrfach-Zertifizierung ermöglicht universellen Einsatz, reduziert Teilevielfalt und sorgt so für Einsparungen in der Logistik.
  • Betriebsspannung von 1000 V nach UL für Nordamerika zulässig.
  • Als 4-adrige Variante und 3+3-erdsymetrische Variante erhältlich.

Anwendungsbereiche

  • Zur Verbindung von Frequenzumrichter und Motor.
  • Zur festen Verlegung und gelegentlichen Bewegung.
  • Einsetzbar in trockenen, feuchten und nassen Umgebungen.
  • Für mittlere mechanische Beanspruchung geeignet.
  • PVC-Außenmantel ist beständig gegenüber Säuren und Laugen und bedingt ölbeständig.
  • Für den Außenbereich geeignet, unter Beachtung des Temperaturbereichs.

Technische Daten

Allgemeine Informationen
Marke ÖLFLEX®
Produkttyp Motoranschlussleitung
Gewicht 7590 kg/km
Kupferzahl 6394 kg/km
Industrie Segment Stromnetze; Lebensmittelindustrie; Medizintechnik & Pharma; Werkzeugmaschinen; Prozessindustrie; Schiffbau
Zolltarifnummer 85444999
Elektrische Kennwerte
Nennspannung Leistungsadern U0/U: 0,6/1 kV AC rms nach IEC
Nennspannung U0/U: 0,6/1 kV AC rms nach IEC
Bemessungsspannung 1000 V AC rms nach UL AWM; 1000 V AC rms nach cRU AWM
Prüfspannung Ader/Ader 4 kV
Prüfspannung Ader/Schirm 4 kV
Prüfspannung 4 kV
Strombelastbarkeit nach VDE 0298-4
Kurzschlusstemperatur [5s] 250 °C
Max. Leiterwiderstand bei 20 °C 0,129 Ω/km
Produktaufbau
Leiter Anzahl/Größe 4G150
Leiternennquerschnitt (metrisch) 150 mm²
Leiternennquerschnitt (AWG) 250 kcmil
Leitermaterial blankes Kupfer
Leiteraufbau IEC 60228 Klasse 5: feindrähtig
Einschließlich Schutzleiter Ja
Anzahl Adern 4
Leitungselement 1 Leistungsader: 4G150
Verseilart Lagenverseilung
Geschirmt Ja
Art des Gesamtschirm alukaschierte Kunststofffolie; verzinntes Kupfergeflecht
Nennaussendurchmesser 52,9 mm
Leitungsform rund
Grundmaterial der Aderisolation Vernetztes Polyethylen
Grundmaterial der Aderisolation, Kurzform XLPE
Grundmaterial des Außenmantels Polyvinylchlorid
Grundmaterial des Außenmantels, Kurzform PVC
Außenmantelfarbe schwarz
Außenmantelfarbe RAL Ton RAL 9005
Aderidentifizierung Farben
Ader Farbcode VDE 0293-308
Produkteigenschaften
Einsatzgebiet flexibel; feste Verlegung
Minimaler Biegeradius, festverlegt 4 x Außendurchmesser
Minimaler Biegeradius in mm, festverlegt 211,6 mm
Minimaler Biegeradius, gelegentlich bewegt 15 x Außendurchmesser
Minimaler Biegeradius in mm, gelegentlich bewegt 793,5 mm
Temperatur, fest verlegt -40 °C bis 90 °C max. Leitertemperatur nach EN; bis 80 °C max. Leitertemperatur nach UL AWM; bis 80 °C max. Leitertemperatur nach CSA AWM
Temperatur, fest verlegt max 90 °C
Temperatur, fest verlegt min -40 °C
Temperatur, gelegentlich bewegt -15 °C bis 90 °C max. Leitertemperatur nach EN; bis 80 °C max. Leitertemperatur nach UL AWM; bis 80 °C max. Leitertemperatur nach CSA AWM
Temperatur, gelegentlich bewegt max 90 °C
Temperatur, gelegentlich bewegt min -15 °C
Flammwidrig Ja
Flammwidrigkeit nach IEC 60332-1-2; UL VW-1; CSA FT1
UV-beständig Ja
UV-beständig nach DIN EN ISO 4892-2 Methode A; EN 50620; EN 50525-1 (Leitungen mit schwarzem Mantel sind für dauerhaften Einsatz im Freien geeignet)
Halogenfrei Nein
Ölbeständig Nein
LABS-frei Ja
LABS-frei nach VDMA 24364-B2-L
Kapazitätsarm Ja
Zertifizierungen und Normen
CE gekennzeichnet Ja
UL recognized Ja
UL AWM Zertifizierung 2570 nach UL 758 (e-file number: E63634)
UL listed Nein
cUR recognized Ja
cUR Zertifizierung AWM I A nach CSA C22.2 No. 210-15 (e-file number: E63634); AWM II A nach CSA C22.2 No. 210-15 (e-file number: E63634); AWM I B nach CSA C22.2 No. 210-15 (e-file number: E63634); AWM II B nach CSA C22.2 No. 210-15 (e-file number: E63634)
cUL listed Nein
CSA zertifiziert Nein
CPR Brandklasse Eca

Datenblätter und Zertifikate

Herstellerhinweise
  • Wenn nicht anders spezifiziert, handelt es sich bei allen dargestellten Werten zum Produkt um Nennwerte bei Raumtemperatur. Weitere Wertangaben, wie z.B. Toleranzen erhalten Sie – soweit verfügbar und zur Veröffentlichung freigegeben- auf Anfrage.
  • Die Fotografien und Grafiken sind nicht maßstäblich und keine detailgetreuen Abbildungen der jeweiligen Produkte.
  • Die Abwesenheit von LABS-Rohstoffen schützt nicht vor dem potenziellen Risiko einer Kontamination mit lackbenetzungsstörenden Substanzen bei der späteren Handhabung des Produkts/der Produkte während des Transports, der Lagerung oder der Weiterverarbeitung nach der Lieferung.
  • Sofern anwendbar, handelt es sich um den Vollmetallpreis ohne Zuschläge und MwSt. Verkauf nur an Firmenkunden.
Lieferlängen & Bestellbedingungen
Mindestbestellmenge 1000 M
Bestellintervall 0 M
Individueller Zuschnitt beim Hersteller Ja
Hersteller-Standardlängen 500 M

Offizielle LAPP Produktinformationen, Datenblatt und Zertifikate

Hersteller-Nennwerte. Produktabbildung repräsentativ; Bauform, Farbe und Abmessungen können je Artikel abweichen. Gewichte gelten für das Kabel ohne Verpackung und Trommel. Versand nach verpacktem Gewicht und Maßen.

ÖLFLEX® SERVO 2XSLCY-JB 4G150

Motor connection cable; 4G150; U0/U: 0,6/1 kV; PVC; Shielded; UL recognized; Flexible

Supply lengths and minimum order quantities are restricted. Please request an individual quotation.

Benefits

  • Power supply for large electric drives possible.
  • Variants with balanced cable design and three-part protective earth largely prevent the generation of harmful currents on the motor bearing. A reduction in motor bearing damage contributes to the longevity of electric motors.
  • Ideal protection against electromagnetic interference thanks to double shielding made of aluminium-laminated foil and copper stranded shielding with a high degree of coverage.
  • Low-capacitance XLPE core insulation with outstanding electrical properties enables long transmission paths.
  • Improved core insulation allows conductor temperatures of up to +90°C and therefore a wide range of applications.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
  • UL/CSA certification according to technical data enables the product to be used in the North American market.
  • Product with multiple certifications enables universal use and reduces the variety of parts, thus guaranteeing logistics savings.
  • Operating voltage of 1000 V according to UL, permitted for North America.
  • Available as a 4-core variant and 3+3 balanced variant.

Applications

  • For connecting frequency converters and motors.
  • For fixed installation and occasional movement.
  • Can be used in dry, damp and wet environments.
  • Suitable for medium mechanical stress.
  • The PVC outer sheath is resistant to acids and alkalis and has limited oil resistance.
  • Suitable for outdoor use, subject to the temperature range.

Technical specifications

General information
Brand ÖLFLEX®
Product type Motor connection cable
Weight 7590 kg/km
Copper index 6394 kg/km
Industry segment Power Grids; Food & Beverage; Healthcare & Pharma; Machine tools; Processing Industries; Ships & boats
customs code 85444999
Electrical parameters
Power cores nominal voltage U0/U: 0,6/1 kV AC rms according to IEC
Nominal voltage U0/U: 0,6/1 kV AC rms according to IEC
Rated voltage 1000 V AC rms according to UL AWM; 1000 V AC rms according to cRU AWM
Test voltage core/core 4 kV
Test voltage core/screening 4 kV
Test voltage 4 kV
Current rating according to VDE 0298-4
Short-circuit temperature [5s] 250 °C
Max. conductor resistance at 20°C 0.129 Ω/km
Product design
Conductor number/size 4G150
Nominal conductor cross-section (metric) 150 mm²
Nominal conductor cross-section (AWG) 250 kcmil
Conductor material Bare copper
Conductor design IEC 60228 class 5: fine-wire
Including protective earth Yes
Number of cores 4
Cable element 1 Power core: 4G150
Stranding type Layered stranding
Shielded Yes
Type of overall screening Aluminium-laminated plastic foil; Tin-plated copper braiding
Nominal outer diameter 52.9 mm
Cable shape Round
Core insulation basic material Cross-linked polyethylene
Core insulation basic material, short form XLPE
Basic material of outer sheath Polyvinylchloride
Basic material of outer sheath, short form PVC
Outer sheath colour black
Cable sheath RAL colour RAL 9005
Core identification Colours
Conductor colour code VDE 0293-308
Product features
Application area Flexible; Fixed installation
Minimum bending radius, stationary 4 x outer diameter
Minimum bending radius in mm, fixed installation 211.6 mm
Minimum bending radius, occasionally flexing 15 x outer diameter
Minimum bending radius in mm, occasionally flexing 793.5 mm
Temperature, fixed installation -40 °C to 90 °C max. conductor temperature according to EN; to 80 °C max. conductor temperature according to UL AWM; to 80 °C max. conductor temperature according to CSA AWM
Temperature, fixed installation max 90 °C
Temperature, fixed installation min -40 °C
max. conductor temperature, occasionally moved -15 °C to 90 °C max. conductor temperature according to EN; to 80 °C max. conductor temperature according to UL AWM; to 80 °C max. conductor temperature according to CSA AWM
Temperature, occasionally moved max 90 °C
Temperature, occasionally moved min -15 °C
Flame-retardant Yes
Flame retardance according to IEC 60332-1-2; UL VW-1; CSA FT1
UV-resistant Yes
UV-resistant according to DIN EN ISO 4892-2 method A; EN 50620; EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)
Halogen-free No
Oil-resistant No
PWIS-free Yes
PWIS-free according to VDMA 24364-B2-L
Low capacitance Yes
Certifications and standards
CE marking Yes
UL recognized Yes
UL AWM certification 2570 according to UL 758 (e-file number: E63634)
UL listed No
cUR recognised Yes
cUR certification AWM I A according to CSA C22.2 No. 210-15 (e-file number: E63634); AWM II A according to CSA C22.2 No. 210-15 (e-file number: E63634); AWM I B according to CSA C22.2 No. 210-15 (e-file number: E63634); AWM II B according to CSA C22.2 No. 210-15 (e-file number: E63634)
cUL listed No
CSA certified No
CPR fire class Eca

Datasheets and certificates

Manufacturer notes
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.
  • If applicable, the prices are solid metal prices without surcharges and VAT. Sales only to business customers.
Supply lengths & ordering conditions
Minimum order quantity 1000 M
Order quantity interval 0 M
Manufacturer individual cut lengths Yes
Manufacturer standard lengths 500 M

Official LAPP product information, datasheet and certificates

Manufacturer nominal values. Representative product image; construction, colour and dimensions may vary by article. Cable weights exclude packaging and reels. Shipping depends on packed weight and dimensions.

Weight N/A
laenge

10 m, 20 m, 50 m, 100 m

Cross-section

150 mm²

Aderzahl

4

Colour

schwarz

Shielding

Ja

Reviews

There are no reviews yet.

You must purchase this product before you can write a review. Sign in with the account you used to place your order.

Shopping Cart
Scroll to Top
WhatsApp