Benefits
- Very robust due to reinforced outer sheath with a wall thickness of at least 1.8 mm.
- The conductor circuits are well decoupled thanks to the twin cabling (TP, Twisted Pair) with short lay lengths.
- Ideal protection against electromagnetic interference thanks to static shielding with aluminium-laminated foil and copper drain wire for the shield contact.
Applications
- Can be used universally at machine interfaces for many applications for data and signal transmission in the low-frequency range.
- For use in control, regulation and measurement circuits.
- For fixed installation and occasional movement.
- Can be used in dry and damp environments.
- The PVC outer sheath is resistant to acids and alkalis and has limited oil resistance.
- Black variants are suitable for outdoor use.
Technical specifications
General information
| Brand | UNITRONIC® |
|---|---|
| Product type | Computer cable |
| Weight | 107 kg/km |
| Copper index | 31 kg/km |
| customs code | 85444993 |
Electrical parameters
| Test voltage core/core | 2 kV |
|---|---|
| Test voltage core/screening | 1 kV |
| Max. conductor resistance at 20°C | 14.3 Ω/km |
| Conductor/conductor operating capacitance (800Hz), approx. | 122 nF/km |
| Conductor/shielding operating capacitance (800Hz), approx. | 189 nF/km |
| Inductance (800 Hz), approx. | 0.632 mH/km |
Product design
| RE process computer cables | RE-2Y(ST)Yv |
|---|---|
| Cable dimensions | 1X2X1.3 |
| Nominal conductor cross-section (metric) | 1.3 mm² |
| Conductor material | Bare copper |
| Conductor design | 7-wire |
| Including protective earth | No |
| Number of pairs | 1 |
| Stranding type | Twisted-pair |
| Shielded | Yes |
| Type of overall screening | Aluminium-laminated plastic foil |
| Nominal outer diameter | 8.4 mm |
| Cable shape | Round |
| Core insulation basic material | Polyethylene |
| Core insulation basic material, short form | PE |
| Additional communication core | Yes |
| Basic material of outer sheath | Polyvinylchloride |
| Basic material of outer sheath, short form | PVC |
| With reinforced outer sheath | Yes |
| Outer sheath colour | black |
| Core identification | Colours and numbers |
Product features
| Application area | Flexible; Fixed installation |
|---|---|
| Minimum bending radius, stationary | 7.5 x outer diameter |
| Minimum bending radius in mm, fixed installation | 63 mm |
| Minimum bending radius, occasionally flexing | 15 x outer diameter |
| Minimum bending radius in mm, occasionally flexing | 126 mm |
| Temperature, fixed installation | -40 °C to 80 °C max. conductor temperature |
| Temperature, fixed installation max | 80 °C |
| Temperature, fixed installation min | -40 °C |
| max. conductor temperature, occasionally moved | -5 °C to 50 °C max. conductor temperature |
| Temperature, occasionally moved max | 50 °C |
| Temperature, occasionally moved min | -5 °C |
| Flame-retardant | Yes |
| Flame retardance according to | IEC 60332-1-2 |
| UV-resistant | Yes |
| UV-resistant according to | EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use) |
| Ozone-resistant | Yes |
| Halogen-free | No |
| Oil-resistant | No |
| PWIS-free | Yes |
| PWIS-free according to | VDMA 24364-B2-L |
Certifications and standards
| CE marking | Yes |
|---|---|
| VDE certified | No |
| CPR fire class | Eca |
| Flame retardance tested according to UN/ECE-R118 | No |
Datasheets and certificates
- Data sheet: DB0032400EN.pdf
- Data sheet: DB1032401EN.pdf
- CE declaration of conformity: CE1032401EN.pdf
- CE declaration of conformity: CE0032400EN.pdf
- CPR declaration of performance: UILCPRDOP17_1032401-1EN.pdf
Manufacturer notes
- Inductance and operating capacitance are neither defined nor controlled electrical parameters. The specified values were determined by calculation and may deviate due to tolerances.
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- The absence of PWIS raw materials does not protect against the potential risk of contamination with substances that interfere with the paint wetting during subsequent handling of the product(s) during transport, storage or further processing after delivery.
LAPP product information and documents
Manufacturer nominal values; images are representative. The confirmed configuration, quantity and displayed total apply to the order.





Reviews