Article specifications
| Part no. | 11022081 |
|---|---|
| Item description | SOLARFLEX®-X H1Z2Z2-K BLUE 1 x 70 mm² |
| Sheath colour | blue |
| AWG, approx. | 2/0 |
| Outer diameter, approx. (mm) | 15,6 - 16,6 |
| Copper factor per km | 672,0 |
| Weight, approx. (kg/km) | 766,0 |
| Reaction to fire class | Eca |
| Metres per packaging unit | - |
| Custom cut lengths available | yes |
| EAN / GTIN | 4060892526930 |
| Customs tariff number | 85446010 |
Manufacturer technical information
Cross-linked single core cable acc. to DIN VDE 0283-618 / DIN EN 50618
Temperature range
flexible -25°C to +60°C
fixed -40°C to +90°C
fixed -40°C to +90°C
Permissible operating temperature of the conductor
+120°C
Short circuit temperature at the conductor
+250°C (Short circuit duration max. 5 s)
Nominal voltage
AC U0/U 1000/1000 V
DC U0/U 1500/1500 V
DC U0/U 1500/1500 V
Test voltage
6500 V
Minimum bending radius
flexible 6x Outer-Ø
fixed 4x Outer-Ø
fixed 4x Outer-Ø
Cable Structure
- Copper wire tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5
- Core insulation: cross-linked compound
- x = without protective conductor
- Outer sheath: cross-linked compound
- Sheath colour: see datasheet
Properties
- resistant to: UV radiation, ozone, weathering effects, water
- for outdoor use
- direct burial
- halogen-free
Tests
- halogen-free acc. to DIN VDE 0482-754-1 / DIN EN 60754-1 / IEC 60754-1
- flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1-2
- smoke density acc. to DIN VDE 0482-1034-1+2 / DIN EN 61034-1+2 / IEC 61034-1+2
- UV-resistant acc. to DIN VDE 0283-618 / DIN EN 50618 Appendix E
- ozone-resistant acc. to DIN VDE 0283-618 / DIN EN 50618
- weather-resistant acc. to DIN VDE 0283-618 / DIN EN 50618 Appendix E
- water-resistant acc. to DIN VDE 0285-525-2-21 / DIN EN 50525-2-21 Appendix E
- Current carrying capacity acc. to DIN VDE 0283-618 / DIN EN 50618
- Short-circuit and earth-fault proof acc. to DIN VDE 0100-520 / HD 60364-5-52
- DC Voltage resistance of the insulation acc. to DIN VDE 0283-618 / DIN EN 50618 Tab. 2
- certifications and approvals:
- EAC
- TÜV Rheinland
Notes
- the conductor is metrically (mm²) constructed, AWG numbers are approximated, and are for reference only
- the installation instructions must be observed
Application
- SOLARFLEX®-X H1Z2Z2-K is used for wiring solar modules. Suitable for direct burial. Not suitable for permanent installation in water. The maximum permissible DC voltage of the system in which the cable is installed must not exceed 1.8 kV. The cable is suitable for use in and on devices and systems with protective insulation (protection class II).



Reviews
There are no reviews yet.